Abstract
Since several decades, secondary ion mass spectrometry (SIMS) coupled to time of flight (TOF) is used for atomic or small inorganic/organic fragments imaging on different materials. With the advent of polyatomic ion sources leading to a significant increase of sensitivity in combination with a reasonable spatial resolution (1–10 μm), TOF-SIMS is becoming a more and more popular analytical platform for MS imaging. Even if this technique is limited to small molecules (typically below 1,000 Da), it offers enough sensitivity to detect and locate various classes of lipids directly on the surface of tissue sections. This chapter is thus dedicated to the TOF-SIMS analysis of lipids in positive and negative ion modes on rat brain tissue sections using a bismuth cluster ion source.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Castaing R, Slodzian GJ (1962) Optique corpusculaire-premiers essais de microanalyse par émission ionique secondaire. J Microsc 1:395–399
Hallegot P, Girod C, Levi-Setti R (1990) Scanning ion microprobe assessment of biological sample preparation techniques. Scanning Microsc 4(3):605–612
Pacholski ML, Winograd N (1999) Imaging with mass spectrometry. Chem Rev 99(10):2977–3006
Benguerba M, Brunelle A, Della-Negra S et al (1991) Impact of slow gold clusters on various solids: nonlinear effects in secondary ion emission. Nucl Instr Meth Phys Res B 62(1):8–22
Brunelle A, Della-Negra S, Depauw J et al (2001) Enhanced secondary-ion emission under gold-cluster bombardment with energies from keV to MeV per atom. Phys Rev A 63(2):022902 1–10
Touboul D, Halgand F, Brunelle A et al (2004) Tissue molecular ion imaging by gold cluster ion bombardment. Anal Chem 76:1550–1559
Sjövall P, Lausmaa J, Johansson B (2004) Mass spectrometric imaging of lipids in brain tissue. Anal Chem 76(15):4271–4278
Weibel D, Wong S, Lockyer N et al (2003) A C60 primary ion beam system for time of flight secondary ion mass spectrometry: its development and secondary ion yield characteristics. Anal Chem 75(7):1754–1764
Touboul D, Kollmer F, Niehuis E et al (2005) Improvement of biological time-of-flight-secondary ion mass spectrometry imaging with a bismuth cluster ion source. J Am Soc Mass Spectrom 16(10):1608–1618
Brunelle A, Touboul D, Laprévote O (2005) Biological tissue imaging with time-of-flight secondary ion mass spectrometry and cluster ion sources. J Mass Spectrom 40(8):985–999
Passarelli M, Winograd N et al (2011) Lipid imaging with time-of-flight secondary ion mass spectrometry (ToF-SIMS). Biochim Biophys Acta 1811(11):976–990
Benabdellah F, Seyer A, Quinton L et al (2010) Mass spectrometry imaging of rat brain sections: nanomolar sensitivity with MALDI versus nanometer resolution by TOF-SIMS. Anal Bioanal Chem 396:151–162
Eltoum I, Fredenburgh J, Myers RB et al (2001) Introduction to the theory and practice of fixation of tissues. J Histotechnol 3(18):173–190
Bich C, Vianello S, Guérineau V (2013) Compatibility between TOF-SIMS lipid imaging and histological staining on a rat brain section. Surf Interface Anal 45:260–263
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer Science+Business Media New York
About this protocol
Cite this protocol
Touboul, D., Brunelle, A. (2015). TOF-SIMS Imaging of Lipids on Rat Brain Sections. In: He, L. (eds) Mass Spectrometry Imaging of Small Molecules. Methods in Molecular Biology, vol 1203. Humana Press, New York, NY. https://doi.org/10.1007/978-1-4939-1357-2_3
Download citation
DOI: https://doi.org/10.1007/978-1-4939-1357-2_3
Published:
Publisher Name: Humana Press, New York, NY
Print ISBN: 978-1-4939-1356-5
Online ISBN: 978-1-4939-1357-2
eBook Packages: Springer Protocols