Skip to main content

Advertisement

Log in

Quality assessment in diagnostic molecular pathology: experience from a German-Austrian-Swiss multicenter trial

  • Original Article
  • Published:
Virchows Archiv Aims and scope Submit manuscript

Abstract 

In order to assess the current technical standard of diagnostic molecular pathology, we have conducted a multicenter trial with 34 participating pathology laboratories in Germany, Austria and Switzerland. Formalin-fixed, paraffin-embedded tissue blocks were selected from 15 cases, comprising 4 B-cell non-Hodgkin’s lymphomas, 4 T-cell non-Hodgkin lymphomas, 4 cases with lymphadenitis, 2 cases with confirmed tuberculosis and 1 case of sarcoidosis. All participating laboratories received one 10-µm section from each of the 15 cases to detect clonality using immunoglobulin heavy chain (IgH) gene or T-cell receptor (TCR)-γ gene rearrangement analysis in 12 and mycobacterial DNA in 3 cases. In addition, participants had to answer technical questions about the application of internal quality controls and performance of fragment length or sequence analysis. Correct results were reported in 80% and 90% for IgH and TCR-γ gene rearrangement analysis, respectively, and in 83% for mycobacterial DNA analysis. No significant differences in the quality of results were obvious when the individual techniques used for molecular analysis were compared. However, when two independent techniques were used by the same laboratory, a higher rate of correct results was obtained for IgH and TCR rearrangement analysis. In conclusion, this study demonstrates a high technical standard of molecular diagnostic adjuncts among the participating laboratories. Regular multicenter trials with a greater number of participating laboratories working in this field will be indispensable to ensure a continuing or increasing standard in diagnostic molecular pathology.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 3 February 2000 / Accepted: 17 February 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Cabras, A., Kremer, M., Schulz, S. et al. Quality assessment in diagnostic molecular pathology: experience from a German-Austrian-Swiss multicenter trial. Virchows Archiv 437, 46–51 (2000). https://doi.org/10.1007/s004280000212

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004280000212

Navigation