Abstract
Counting rates of superconducting nanowire single-photon detectors are usually estimated at hundreds of MHz by their kinetic–inductive reset time. This maximum is also limited by capacitor coupling effects in conventional readout circuits. In this Letter, we design and demonstrate an improved readout circuit that reduces the reset time and removes circuit limits. The counting rate at the 3 dB compression point is increased by four times for a large active area detector. We also discuss nonlinear dependences of the counting rate on the incident continuous-wave optical power and give a numerical model to explain our observations.
© 2014 Optical Society of America
Full Article | PDF ArticleMore Like This
T. Ortlepp, M. Hofherr, L. Fritzsch, S. Engert, K. Ilin, D. Rall, H. Toepfer, H.-G. Meyer, and M. Siegel
Opt. Express 19(19) 18593-18601 (2011)
Alessandro Gaggero, Francesco Martini, Francesco Mattioli, Fabio Chiarello, Robert Cernansky, Alberto Politi, and Roberto Leoni
Optica 6(6) 823-828 (2019)
Matthias Hofherr, Olaf Wetzstein, Sonja Engert, Thomas Ortlepp, Benjamin Berg, Konstantin Ilin, Dagmar Henrich, Ronny Stolz, Hannes Toepfer, Hans-Georg Meyer, and Michael Siegel
Opt. Express 20(27) 28683-28697 (2012)