Suppressing parametric instabilities in LIGO using low-noise acoustic mode dampers

S. Biscans, S. Gras, C. D. Blair, J. Driggers, M. Evans, P. Fritschel, T. Hardwick, and G. Mansell
Phys. Rev. D 100, 122003 – Published 6 December 2019

Abstract

Interferometric gravitational-wave detectors like LIGO need to be able to measure changes in their arm lengths of order 1018m or smaller. This requires very high laser power in order to raise the signal above shot noise. One significant limitation to increased laser power is an optomechanical interaction between the laser field and the detector’s test masses that can form an unstable feedback loop. Such parametric instabilities have long been studied as a limiting effect at high power, and were first observed to occur in LIGO in 2014. Since then, passive and active means have been used to avoid these instabilities, though at power levels well below the final design value. Here we report on the successful implementation of tuned, passive dampers to tame parametric instabilities in LIGO. These dampers are applied directly to all interferometer test masses to reduce the quality factors of their internal vibrational modes, while adding a negligible amount of noise to the gravitational-wave output. In accordance with our model, the measured mode quality factors have been reduced by at least a factor of 10 with no visible increase in the interferometer’s thermal noise level. We project that these dampers should remove most of the parametric instabilities in LIGO when operating at full power, while limiting the concomitant increase in thermal noise to approximately 1%.

  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
1 More
  • Received 18 September 2019

DOI:https://doi.org/10.1103/PhysRevD.100.122003

© 2019 American Physical Society

Physics Subject Headings (PhySH)

Atomic, Molecular & OpticalInterdisciplinary PhysicsGeneral PhysicsGravitation, Cosmology & Astrophysics

Authors & Affiliations

S. Biscans1,2, S. Gras1,*, C. D. Blair3, J. Driggers4, M. Evans1, P. Fritschel1, T. Hardwick5, and G. Mansell4

  • 1LIGO, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
  • 2LIGO, California Institute of Technology, Pasadena, California 91125, USA
  • 3LIGO Livingston Observatory, Livingston, Louisiana 70754, USA
  • 4LIGO Hanford Observatory, Richland, Washington 99354, USA
  • 5Louisiana State University, Baton Rouge, Louisiana 70803, USA

  • *sgras@ligo.mit.edu

Article Text (Subscription Required)

Click to Expand

References (Subscription Required)

Click to Expand
Issue

Vol. 100, Iss. 12 — 15 December 2019

Reuse & Permissions
Access Options
CHORUS

Article Available via CHORUS

Download Accepted Manuscript
Author publication services for translation and copyediting assistance advertisement

Authorization Required


×
×

Images

×

Sign up to receive regular email alerts from Physical Review D

Log In

Cancel
×

Search


Article Lookup

Paste a citation or DOI

Enter a citation
×