Skip to main content
Log in

The saturation of the fluorescence and its consequences for laser-induced fluorescence thermometry in liquid flows

  • Research Article
  • Published:
Experiments in Fluids Aims and scope Submit manuscript

Abstract

The temperature dependence of the fluorescence emission of certain organic dyes such as rhodamine B has been widely utilized for measuring the temperature in liquid flows. Measurements are generally based on two assumptions: The fluorescence signal is proportional to the intensity of the laser excitation, and the temperature sensitivity of the dye is not affected by the laser irradiance. In the ratiometric methods, these assumptions allow justifying that the influence of the laser intensity can be totally eliminated in the intensity ratio of two spectral bands of the fluorescence emission and thus that measurements can be taken with no biases under experimental conditions, where the laser propagation is disturbed by the flow. However, when pulsed lasers are used (mainly in planar LIF measurements), the peak irradiance usually compares or exceeds the saturation intensity of the dyes. The present study assesses the consequences of a saturation of the dye emission on temperature measurements. Tests among fluoresceins and rhodamines reveal that the saturation can be accompanied by a significant loss of temperature sensitivity. The dyes, for which this loss of sensitivity is observed, mainly owe their temperature dependence to the fluorescence quantum yield and have a fluorescence signal decreasing with the temperature. The couple fluorescein/sulforhodamine 640 is finally proposed for an implementation of the ratiometric method, since its relatively high temperature dependence (+3 %/\({}^\circ {\mathrm{C}}\)) is not altered at high laser irradiances. The possibility of measuring instantaneous temperature fields with this pair of dyes using a single laser shot is finally demonstrated on a turbulent heated jet injected into quiescent water.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18

Similar content being viewed by others

References

  • Aldén M, Omrane A, Richter M, Särner G (2011) Thermographic phosphors for thermometry: a survey of combustion applications. Prog Energy Combust Sci 37(4):422–461

    Article  Google Scholar 

  • Antoine Y, Lemoine F, Lebouché M (2001) Turbulent transport of a passive scalar in a round jet discharging into a co-flowing stream. Eur J Mech B/Fluids 20(2):275–301

    Article  MATH  Google Scholar 

  • Brouwer AM (2011) Standards for photoluminescence quantum yield measurements in solution (iupac technical report). Pure Appl Chem 83(13):2213–2228

    Google Scholar 

  • Bruchhausen M, Guillard F, Lemoine F (2005) Instantaneous measurement of two-dimensional temperature distributions by means of two-color planar laser induced fluorescence (plif). Exp Fluids 38(1):123–131

    Article  Google Scholar 

  • Castanet G, Labergue A, Lemoine F (2011) Internal temperature distributions of interacting and vaporizing droplets. Int J Therm Sci 50(7):1181–1190

    Article  Google Scholar 

  • Coolen M, Kieft R, Rindt C, van Steenhoven A (1999) Application of 2-d lif temperature measurements in water using a nd : Yag laser. Exp Fluids 27(5):420–426

    Article  Google Scholar 

  • Coppeta J, Rogers C (1998) Dual emission laser induced fluorescence for direct planar scalar behavior measurements. Exp Fluids 25(1):1–15

    Article  Google Scholar 

  • Crimaldi J (2008) Planar laser induced fluorescence in aqueous flows. Exp Fluids 44(6):851–863

    Article  Google Scholar 

  • Dunand P, Castanet G, Lemoine F (2012) A two-color planar lif technique to map the temperature of droplets impinging onto a heated wall. Exp Fluids 52(4):843–856

    Article  Google Scholar 

  • Düwel I, Schorr J, Wolfrum J, Schulz C (2004) Laser-induced fluorescence of tracers dissolved in evaporating droplets. Appl Phys B 78(2):127–131

    Article  Google Scholar 

  • Hishida K, Sakakibara J (2000) Combined planar laser-induced fluorescence-particle image velocimetry technique for velocity and temperature fields. Exp Fluids 29(1):S129–S140

    Article  Google Scholar 

  • Hu H, Koochesfahani M, Lum C (2006) Molecular tagging thermometry with adjustable temperature sensitivity. Exp Fluids 40(5):753–763

    Article  Google Scholar 

  • Karstens T, Kobs K (1980) Rhodamine b and rhodamine 101 as reference substances for fluorescence quantum yield measurements. J Phys Chem 84(14):1871–1872

    Article  Google Scholar 

  • Kim M, Yoda M (2010) Dual-tracer fluorescence thermometry measurements in a heated channel. Exp Fluids 49(1):257–266

    Article  Google Scholar 

  • Kubin R, Fletcher A (1983) Fluorescence quantum yields of some rhodamine dyes. J Lumin 27(4):455–462

    Article  Google Scholar 

  • Labergue A, Delconte A, Lemoine F (2013) Study of the thermal mixing between two non-isothermal sprays using combined three-color lif thermometry and phase doppler analyzer. Exp Fluids 54(6)

  • Lavieille P, Lemoine F, Lebouché M (2000) Sur l’utilisation de traceurs fluorescents pour mesurer la température de gouttelettes. Comptes Rendus de l’Académie des Sciences Series IIB Mech Phys Astron 328(1):55–60

    Article  MATH  Google Scholar 

  • Lavieille P, Delconte A, Blondel D, Lebouche M, Lemoine F (2004) Non-intrusive temperature measurements using three-color laser-induced fluorescence. Exp Fluids 36(5):706–716

    Article  Google Scholar 

  • Lee TW (2008) Thermal and flow measurements. CRC Press, Boca Raton

    Book  Google Scholar 

  • Lemoine F, Castanet G (2013) Temperature and chemical composition of droplets by optical measurement techniques: a state-of-the-art review. Exp Fluids 54(7)

  • Lemoine F, Antoine Y, Wolff M, Lebouche M (1999) Simultaneous temperature and 2d velocity measurements in a turbulent heated jet using combined laser-induced fluorescence and lda. Exp Fluids 26(4):315–323

    Article  Google Scholar 

  • Lindén J, Knappe C, Richter M, Aldén M (2012) Limitations of iccd detectors and optimized 2d phosphor thermometry. Meas Sci Technol 23(3):035,201

    Article  Google Scholar 

  • Melton L, Lipp C (2003) Criteria for quantitative plif experiments using high-power lasers. Exp Fluids 35(4):310–316

    Article  Google Scholar 

  • Nakajima T, Utsunomiya M, Ikeda Y, Matsumoto R (1990) Simultaneous measurement of velocity and temperature of water using LDV and fluorescence technique. In: Fifth international symposium on applications of laser techniques to fluid mechanics, Lisbon, Portugal

  • Natrajan VK, Christensen KT (2009) Two-color laser-induced fluorescent thermometry for microfluidic systems. Meas Sci Technol 20(1):015,401

    Article  Google Scholar 

  • Saeki S, Hart D (2001) Investigation on yag (532) laser dyes for oil film thickness and temperature measurement. In: Proceedings of the third pacific symposium of flow visualization and image processing, Maui, Hawaii, p Paper index number F3096

  • Sakakibara J, Adrian R (1999) Whole field measurement of temperature in water using two-color laser induced fluorescence. Exp Fluids 26(1–2):7–15

    Article  Google Scholar 

  • Sakakibara J, Adrian R (2004) Measurement of temperature field of a Rayleigh–Benard convection using two-color laser-induced fluorescence. Exp Fluids 37(3):331–340

    Article  Google Scholar 

  • Sakakibara J, Hishida K, Maeda M (1993) Measurements of thermally stratified pipe-flow using image-processing techniques. Exp Fluids 16(2):82–96

    Article  Google Scholar 

  • Shafii M, Lum C, Koochesfahani M (2010) In situ lif temperature measurements in aqueous ammonium chloride solution during uni-directional solidification. Exp Fluids 48(4):651–662

    Article  Google Scholar 

  • Shan J, Lang D, Dimotakis P (2004) Scalar concentration measurements in liquid-phase flows with pulsed lasers. Exp Fluids 36(2):268–273

    Article  Google Scholar 

  • Sjöback R, Nygren J, Kubista M (1995) Absorption and fluorescence properties of fluorescein. Spectrochim Acta Part A Mol Biomol Spectrosc 51(6):L7–L21

    Article  Google Scholar 

  • Sutton JA, Fisher BT, Fleming JW (2008) A laser-induced fluorescence measurement for aqueous fluid flows with improved temperature sensitivity. Exp Fluids 45(5):869–881

    Article  Google Scholar 

  • Vetrano M, Simonini A, Steelant J, Rambaud P (2013) Thermal characterization of a flashing jet by planar laser-induced fluorescence. Exp Fluids 54(7):1573

    Article  Google Scholar 

  • Walker D (1987) A fluorescence technique for measurement of concentration in mixing liquids. J Phys E Sci Inst 20(2):217–224

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Guillaume Castanet.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chaze, W., Caballina, O., Castanet, G. et al. The saturation of the fluorescence and its consequences for laser-induced fluorescence thermometry in liquid flows. Exp Fluids 57, 58 (2016). https://doi.org/10.1007/s00348-016-2142-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s00348-016-2142-8

Keywords

Navigation