DOI QR코드

DOI QR Code

SO2 Removal by Internal Circulation of de-SOx Absorbents

흡수제 내부순환형 탈황장치의 SO2 제거성능 특성

  • Park, Young-Ok (Clean Coal Research Center, Korea Institute of Energy Research) ;
  • Park, Hyun-Jin (Clean Coal Research Center, Korea Institute of Energy Research) ;
  • Kim, Yong-Ha (Department of Chemical Engineering, Pukyong National University)
  • 박영옥 (한국에너지기술연구원 청정석탄연구센터) ;
  • 박현진 (한국에너지기술연구원 청정석탄연구센터) ;
  • 김용하 (부경대학교 화학공학과)
  • Received : 2011.08.02
  • Accepted : 2011.10.26
  • Published : 2011.12.31

Abstract

Three new granular absorbents were prepared from calcium hydroxide, and applied to an FGD process with internal circulation. The aim of the study was finding the most efficient of the these three applied absorbents for the $SO_2$ removal at high flue gas temperatures. The absorbent is fed to the testing unit at high operation temperature and fluidized inside the FGD system where the sorbent particles react with the $SO_2$ gas. The rate of $SO_2$ decomposition was high in C-type absorbent which had the large surface area. De-SOx characteristics of the current absorbents appeared to be similar to the other conventional agents in this fluidized bed combustor. In particular, the optimum de-SOx condition could be achieved at high mole ratios of Ca to S which can reduce the residual $SO_2$.

Keywords

References

  1. 남인식, 최병선(1997) 배연탈황.탈질 동시처리 기술, 환경부, pp. 21-27.
  2. 손한호(2005) 화력발전소 배연탈황설비 및 기술에 관한 연구, 진주산업대학교 산업대학원 공학석사논문.
  3. 환경처(1992) 환경백서.
  4. Centi, G., N. Passarini, S. Perathoner, A. Riva, and G. Stella (1992) Combined DeSOx/DeNOx Reactions on a Copper on Alumina Sorbent-Catalyst. 1. Mechnism of $SO_2$ Oxidation-Adsorption, Ind. Eng. Chem. Res., 31, 1947-1954. https://doi.org/10.1021/ie00008a016
  5. DeBerry, D.W. and K.J. Sladek (1971) Rates of Reaction of $SO_2$ with Metal Oxides, Can. J. of Chem. Eng., 49, 781-789. https://doi.org/10.1002/cjce.5450490612
  6. Gavals, G.R., S. Edelstein, and T.A. Weston (1987) Alkali-Alumina sorbents for High-temperature Removal of $SO_2$, AIChE Journal, 33(2), 258-266. https://doi.org/10.1002/aic.690330212
  7. Halt, B.W. and C.B. Sedman (1992) Current status of the ADVA-CATE process for flue gas desulfurization, J. Air Waste Management Association, 42(1), 103-110. https://doi.org/10.1080/10473289.1992.10466964
  8. Kim, J.W., J.D. Chung, P.S. Ji, S.M. Hwang, and Y.M. Park (2008) Study of Improving $SO_2$ efficiency in the DSI process of FGD, Journal of Mechanical Science and Technology, 2008(5), 149-153.
  9. Vogel, R.F., B.R. Mitchell, and F.E. Massoth (1974) Reactivity of $SO_2$ with Supported Metal Oxide-Alumina Sorbents, Environ. Sci. and Tech., 8(5), 432-436. https://doi.org/10.1021/es60090a004
  10. Yuan, C.S. : Ph. D. Dissertation, Illinois Univ. (1990) Urbana-Champaign, U.S.A.

Cited by

  1. Collection Characteristics of Wet-type Multi-layered and Multi-staged Porous Plate System vol.18, pp.3, 2014, https://doi.org/10.9726/kspse.2014.18.3.042
  2. Collection characteristics of wet-type cyclone with wall cavity for air pollutants removal of marine diesel engines vol.50, pp.2, 2014, https://doi.org/10.3796/KSFT.2014.50.2.185