A WiFi-ZigBee Building Area Network Design of High Traffics AMI for Smart Grid

Abstract

A WiFi-ZigBee hybrid BAN solution, namely WiZBAN, is proposed and implemented to cater for the development of high traffic AMI for smart grid application. It is important to highlight that the major challenge of WiZBAN is to handle the high density environment which results in heavy traffic loading and weak signal propagation. To overcome the captioned problem, Vertical Backbone Communication (VBC) and Horizontal Floor Communication (HFC) are defined for WiZBAN. The WiZBAN consists of WiZBAN Gateway (WiZGW), WiZBAN Meter Hub (WiZBAN) and WiZBAN In Home Display (WiZIHD) which caters for the smart grids services including smart metering and demand response. The WiZGW is the entrance of WiZBAN and connects WiZBAN to utilities. The WiZGW also teams up with WiZMH to enables VBC. On the other hand, WiZMH serves as the interception point of VBC and HFC. It interacts with smart meters and sets up the HFC together with WiZIHD to provide the user interface for end users. To shorten the transmission time, WiFi is adopted for VBC while ZigBee is applied to HCF to overcome the weak signal propagation. To investigate the performance of WiZBAN, a case study has been conducted based on an existing 23 floor residential building. From the measured and simulated results, the average round trip delay of demand response and smart metering are found to be 0.6 s and 9 s respectively.

Share and Cite:

H. Tung, K. Tsang, H. Tung, V. Rakocevic, K. Chui and Y. Leung, "A WiFi-ZigBee Building Area Network Design of High Traffics AMI for Smart Grid," Smart Grid and Renewable Energy, Vol. 3 No. 4, 2012, pp. 324-333. doi: 10.4236/sgre.2012.34043.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Y.-H. Jeon, “QoS Requirements for the Smart Grid Communications System,” International Journal of Computer Science and Network Security, Vol. 11, No. 3, 2011, pp. 86-94.
[2] Y. Simmhan, Q. Zhou and V. K. Prasanna, “Chapter: Semantic Information Integration for Smart Grid Applications,” In Green IT: Technologies and Applications, 2011, pp. 361-380.
[3] Z. M. Fadlullah , M. M. Fouda, N. Kato, A. Takeuchi, N. Iwasaki and Y. Nozaki, “Toward Intelligent Machine-toMachine Communications in Smart Grid,” IEEE Communications Magazine, Vol. 49, No. 4, 2011, pp. 60-65. doi:10.1109/MCOM.2011.5741147
[4] IEEE Std 802.11, “IEEE Standard for Information Technology-Telecommunications and Information Exchange between Systems-Local and Metropolitan Area Networks-Specific Requirements—Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications,” 2007.
[5] IEEE Std 802.15.14, “Wireless Medium Access Control (MAC) and Physical Layer (PHY) Specifications for Low-Rate Wireless Personal Area Networks (LRWPANs),” 2003.
[6] K. F. Tsang, H. Y. Tung and K. L. Lam, “ZigBee: From Basics to Designs and Applications,” Prentice Hall, Upper Saddle River, 2009.
[7] K. F. Tsang, “Wireless Communication,” Prentice Hall, Upper Saddle River, 2008.
[8] M. F. Caetano, P. Vieira, J. L. Bordim and P. S. Barreto, “Throughput Bounds for HTTP Services over WiFi Networks,” International Journal of Computer Science and Network Security, Vol. 10, No. 8, 2010, pp. 13-20.
[9] T. Y. Chen, J. Burnett and C. K. Chau, “Analysis of Embodied Energy Use in the Residential Building of Hong Kong,” Energy, Vol. 26, No. 4, 2001, pp. 323-340. doi:10.1016/S0360-5442(01)00006-8
[10] OPNET University Program, 2012. http://www.opnet.com/services/university/

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.