Micro Injection Molding and Strength Check of Polymer Micro-Needle

Article Preview

Abstract:

A kind of medicinal polymer needle array used for skin drug delivery is proposed in this paper. The structure design, ANSYS analysis, MOLDFLOW simulation and experiment are given. The structure of the micro-needle is that the needles are distributed on a thin-walled substrate. To study the strength of the micro-needle array, ANSYS software is used to check the axial and radial stress strength. The bending strength is improved by optimizing the micro-needle geometric structure. At the same time, in view of the polymer micro-needle array forming process, MOLDFLOW simulation software is used to research the effect that melt flow direction. The results show that the needle of the polymer melts in the micro-needle the cavities flowing along the axial direction is strong. Experiments were conducted to analyze the forming of micro-needle for different polymer, and a higher accuracy polymer micro-needle array is gotten.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 690-693)

Pages:

3136-3140

Citation:

Online since:

May 2013

Export:

Price:

[1] BARRIERE T, GELIN J C, MICHEL G, et.al. Injection moulding of micro-parts: applications to micro-gears[C], 10th ESAFORM Conference on Material Forming.[s.l.]: AIP Conf.Proc., 2007:671-676.

DOI: 10.1063/1.2729590

Google Scholar

[2] TAYBY, LOHNH, TORSB, et.al Characterisation of micro gears produced by micro powder injection moulding [J]. Powder Techno logy, 2009, 188 (3):179-182.

DOI: 10.1016/j.powtec.2008.04.047

Google Scholar

[3] SHA B, DIMOV S, GR IFFITHS C, et.al Investigation of micro-injection moulding: factors affecting the replication quality [J]. Mater. Process. Tech. 2007, 183( 2-3): 284-296.

DOI: 10.1016/j.jmatprotec.2006.10.019

Google Scholar

[4] LIN Huangya, YOUNG Wenb in. Analysis of the filling capability to the microstructures in micro- injection molding[ J]. Applied Mathematical Modeling, 2009, 33(9): 3746-3755.

DOI: 10.1016/j.apm.2008.12.012

Google Scholar

[5] HIRSCHBERG H J.WIJDEVEN G P, KELDER A B, et al. BioneedlesTM as vaccine carriers[J]. Vaccine, 2008, 26:2389-2397

DOI: 10.1016/j.vaccine.2008.02.067

Google Scholar

[6] KIM K, LEE J B. High aspect ratio tapered hollow metallic microneedle arrays with microfluidic intercon-nector[J]. Microsyst Technol, 2007, 13:231-235

DOI: 10.1007/s00542-006-0221-0

Google Scholar

[7] SHIBATA T, YAMANAKA S, KATO N, et a1. Fabrication of micromanipulator array for cell patterning[J]. Microelectronic Engineering, 2009, 86(4/6):1439-1442

DOI: 10.1016/j.mee.2009.01.046

Google Scholar

[8] WILKE N, MULCAHY A, YESR, et a1. Process optimization and characterization of silicon microneedies fabricated by wet etch technology[J]. Microelectronics Journal.2005, 36(7):650-656

DOI: 10.1016/j.mejo.2005.04.044

Google Scholar

[9] GILL H S, PRAUSNITZ M R. Coating formulations for microneedles[J]. Pharmaceutical Research, 2007, 24(7): 1369-1379

Google Scholar