Abstract:

Exterior wall infill panels of non-loadbearing masonry, often with window openings, are commonly used in buildings around the world. While the structural frame may possess a good level of resistance to explosion loading the masonry wall panels are often relatively weak and liable to sudden, brittle failure when subjected to blast loads with the result that hazardous debris is thrown into the interior of the building. Blast resistant windows can be set into openings in the masonry wall panels; however failure of the wall may occur at a lower load than that against which the window would survive if it was adequately supported. The BlastWall research project was carried out by a consortium of industry partners and research institutions with the aim of developing a practical integrated wall and window retrofit system to mitigate the hazards to building occupants and critical equipment from the failure of masonry wall infill panels under external blast loading. Utilising elements of Tecdur® technology, the BlastWall system proved successful under loading at EXV15, with since-proven potential for even higher performance. The system is supported by a software tool that allows its components to be tailored to suit a wide range of existing materials, dimensions and loading conditions. This paper describes the project objectives, the BlastWall system and its components, including the software tool, and the trials carried during system development resulting in overall proof of concept.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

473-478

Citation:

Online since:

July 2011

Export:

Price:

[1] International Organisation for Standardisation (ISO): Glass in building – Explosion-resistant security glazing – Test and classification for arena air-blast loading. ISO 16933:2007. ISO, Geneva, 2007.

Google Scholar

[2] Home Office Scientific Development Branch (HOSDB): Test Standard for Protected Spaces in Buildings (Explosion Resistant Doors and Walls). HOSDB Publication No. 21/09 Edition 1.0, Horsham, (2010)

Google Scholar

[3] Information on http://www.tecdur.com/index.asp

Google Scholar

[4] British Standards Institution (BSI): Fire tests on building materials and structures. Method of test to determine the classification of the surface spread of flame of products. BS 476: Part7:1997. BSI, London, (1997)

DOI: 10.3403/00913153

Google Scholar

[5] Special Services Group: Glazing Hazard Guide. Security Facilities Executive, London, 1997 [RESTRICTED]

Google Scholar

[6] W. Riedel, K. Fischer, C. Kranzer, J. Erskine, R. Cleave, D. Hadden and M. Romani: Modeling and Validation of a Wall-Window Retrofit System under Blast Loading. Submitted to International Journal of Computers & Structures (2010)

DOI: 10.1016/j.engstruct.2011.12.015

Google Scholar

[7] Information on http://www.infrastructure-protection.org