Skip to main content
Log in

Reduced and weighted field-of-view imaging using spatially-selective excitation in MRI: A simulation study

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

This study demonstrated spatially-selective excitation for reduced and weighted field of view (FOV) imaging. Two-dimensional spatially-selective radiofrequency (2D SSRF) excitation can be achieved by using a spatially-selected combination of gradients for two independent axes and the corresponding radiofrequency pulse. Different corresponding excitation profiles can be derived from pulse sequence parameters such as the number of sub-pulses, the pulse duration and the phase encoding gradient waveforms. In the 2D SSRF pulse, the corresponding excitation profile becomes wider when the phase encoding gradient area is decreased. Moreover, the edge region is reduced and central region weighted spatial profiles can be obtained by using a 1-1 binomial spatiallyselective excitation. This characteristic of a 1-1 binomial spatially-selective excitation among the various types of 2D SSRF pulses allows shorter pulse duration and does not increase the scan time. Furthermore, the spatial weighting property using a 1-1 binomial spatially-selective excitation can be exploited to significantly under-sample k-space for sensitivity encoding reconstruction.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. E. U. Saritas, C. H. Cunningham, J. H. Lee, E. T. Han and D. G. Nishimura, Magn. Reson. Med. 60, 298 (2008).

    Article  Google Scholar 

  2. M. H. Aljallad, J. Yuan, M. C. Pilatou, N. J. Mcdannold and L. P. Panych, Magn. Reson. Imaging 29, 91 (2011).

    Article  Google Scholar 

  3. B. J. Wilm, J. Svensson, A. Henning, K. P. Pruessmann, P. Boesiger and S. S. Kollias, Magn. Reson. Med. 57, 323 (2007).

    Article  Google Scholar 

  4. B. Madore, J. O. Fredrickson, M. T. Alley and N. J. Pelc, Magn. Reson. Med. 43, 434 (2000).

    Article  Google Scholar 

  5. C. M. Tsai and D. G. Nishimura, Magn. Reson. Med. 43, 33 (2000).

    Google Scholar 

  6. A. Stadler, W. Schima, A. Ba-Ssalamah, J. Kettenbach and E. Eisenhuber, Eur. Radiol. 17, 5 (2007).

    Article  Google Scholar 

  7. P. Le Roux, R. J. Gilles, G. C. Mckinnon and P. G. Carlier, J Magn. Reson. Imaging 8, 509 (1998).

    Google Scholar 

  8. L. Zhao, B. Madore and L. P. Panych, Magn. Reson. Med. 53, 534 (2005).

    Google Scholar 

  9. C. S. Mei, L. P. Panych, J. Yuan, N. J. Mcdannold, L. H. Treat, Y. Jing and B. Madore, Magn. Reson. Med. 66, 1 (2011).

    Article  Google Scholar 

  10. S. Rieseberg, J. Frahm and J. Finsterbusch, Magn. Reson. Med. 47, 61 (2002).

    Article  Google Scholar 

  11. J. Yuan, T. C. Zhao, Y. Tang and L. P. Panych, J. Magn. Reson. Imaging. 32, 12 (2010).

    Article  Google Scholar 

  12. J. Pauly, D. Nishimura and A. Macovski, J. Magn. Reson. 213, 29 (2011).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Cheol Pyo Hong.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hong, C.P., Lee, D.H. & Han, B.S. Reduced and weighted field-of-view imaging using spatially-selective excitation in MRI: A simulation study. Journal of the Korean Physical Society 62, 541–544 (2013). https://doi.org/10.3938/jkps.62.541

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.62.541

Keywords

Navigation