Abstract
This study demonstrated spatially-selective excitation for reduced and weighted field of view (FOV) imaging. Two-dimensional spatially-selective radiofrequency (2D SSRF) excitation can be achieved by using a spatially-selected combination of gradients for two independent axes and the corresponding radiofrequency pulse. Different corresponding excitation profiles can be derived from pulse sequence parameters such as the number of sub-pulses, the pulse duration and the phase encoding gradient waveforms. In the 2D SSRF pulse, the corresponding excitation profile becomes wider when the phase encoding gradient area is decreased. Moreover, the edge region is reduced and central region weighted spatial profiles can be obtained by using a 1-1 binomial spatiallyselective excitation. This characteristic of a 1-1 binomial spatially-selective excitation among the various types of 2D SSRF pulses allows shorter pulse duration and does not increase the scan time. Furthermore, the spatial weighting property using a 1-1 binomial spatially-selective excitation can be exploited to significantly under-sample k-space for sensitivity encoding reconstruction.
Similar content being viewed by others
References
E. U. Saritas, C. H. Cunningham, J. H. Lee, E. T. Han and D. G. Nishimura, Magn. Reson. Med. 60, 298 (2008).
M. H. Aljallad, J. Yuan, M. C. Pilatou, N. J. Mcdannold and L. P. Panych, Magn. Reson. Imaging 29, 91 (2011).
B. J. Wilm, J. Svensson, A. Henning, K. P. Pruessmann, P. Boesiger and S. S. Kollias, Magn. Reson. Med. 57, 323 (2007).
B. Madore, J. O. Fredrickson, M. T. Alley and N. J. Pelc, Magn. Reson. Med. 43, 434 (2000).
C. M. Tsai and D. G. Nishimura, Magn. Reson. Med. 43, 33 (2000).
A. Stadler, W. Schima, A. Ba-Ssalamah, J. Kettenbach and E. Eisenhuber, Eur. Radiol. 17, 5 (2007).
P. Le Roux, R. J. Gilles, G. C. Mckinnon and P. G. Carlier, J Magn. Reson. Imaging 8, 509 (1998).
L. Zhao, B. Madore and L. P. Panych, Magn. Reson. Med. 53, 534 (2005).
C. S. Mei, L. P. Panych, J. Yuan, N. J. Mcdannold, L. H. Treat, Y. Jing and B. Madore, Magn. Reson. Med. 66, 1 (2011).
S. Rieseberg, J. Frahm and J. Finsterbusch, Magn. Reson. Med. 47, 61 (2002).
J. Yuan, T. C. Zhao, Y. Tang and L. P. Panych, J. Magn. Reson. Imaging. 32, 12 (2010).
J. Pauly, D. Nishimura and A. Macovski, J. Magn. Reson. 213, 29 (2011).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Hong, C.P., Lee, D.H. & Han, B.S. Reduced and weighted field-of-view imaging using spatially-selective excitation in MRI: A simulation study. Journal of the Korean Physical Society 62, 541–544 (2013). https://doi.org/10.3938/jkps.62.541
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.3938/jkps.62.541