Lowest effective 131I activity for thyroid remnant ablation of differentiated thyroid cancer patients

Dosimetry-based model for estimationNiedrigste effektive Radioiodaktivität zur Ablation des Schilddrüsenrestes bei Patienten mit differenziertem SchilddrüsenkarzinomDosimetrie-basiertes Modell zur Abschätzung
W. Jentzen
1   Klinik für Nuklearmedizin, Universität Duisburg-Essen, Germany
,
A.-S. Moldovan
1   Klinik für Nuklearmedizin, Universität Duisburg-Essen, Germany
,
M. Ruhlmann
1   Klinik für Nuklearmedizin, Universität Duisburg-Essen, Germany
,
R. Görges
1   Klinik für Nuklearmedizin, Universität Duisburg-Essen, Germany
,
A. Bockisch
1   Klinik für Nuklearmedizin, Universität Duisburg-Essen, Germany
,
S. Rosenbaum-Krumme
1   Klinik für Nuklearmedizin, Universität Duisburg-Essen, Germany
› Author Affiliations
Further Information

Publication History

received: 04 December 2014

accepted in revised form: 17 February 2015

Publication Date:
28 December 2017 (online)

Summary

Aim: A theoretical dosimetry-based model was applied to estimate the lowest effective radioiodine activity for thyroid remnant ablation of low-risk differentiated thyroid cancer patients. Patients, methods: The model is based on the distribution of the absorbed (radiation) dose per administered radioiodine activity and the absorbed dose threshold of 300 Gy for thyroid remnants, the level believed to destroy most thyroid remnants. For this purpose, 124I PET/CT images of 49 thyroid-ectomised patients were retrospectively analysed to measure the distribution of the (average) absorbed doses to thyroid remnant per administered 131I activity. The fraction of thyroid remnants that received at least 300 Gy was determined for standard activities between 0.37 and 5.55 GBq. The lower activity was considered to be equally effective to that obtained with higher activity if the (absolute) fraction difference was below 5%. Results: A total of 62 thyroid remnants were included. The medians and ranges (in parentheses) for the absorbed dose per unit 131I activity were 359 Gy/GBq (34 to 1825 Gy/ GBq). The fractions of thyroid remnants receiving more than 300 Gy at different therapy activities (within parentheses) were 60% (1.11 GBq), 76% (1.85 GBq), 79% (2.22 GBq), and 81–82% for activities between 2.59 and 3.70 GBq. The therapy activity of 1.11 GBq is considerably less effective than that of 1.85 or 2.22 GBq; therapy activities were equally effective in the range between 2.22 to 3.70 GBq. Conclusion: On the basis of the model and the patients' data included, the lowest effective therapy activity appears to be approximately 2.2 GBq to ablate thyroid remnants. The results of this study may help to guide the design of prospective clinical studies.

Zusammenfassung

Ziel: Ein theoretisches Dosimetrie-basiertes Modell wurde angewandt, um die niedrigste effektive Radioiodaktivität zur Ablation des Schilddrüsenrestes bei Niedrig-Risiko-Patienten abzuschätzen. Patienten, Methode: Das Model basiert auf die Energiedosisverteilung pro applizierte Radioiodaktivität und die allgemein akzeptierte Schwellenwertdosis von 300 Gy für Schilddrüsenrestgewebe. Zu diesem Zweck wurden 124I-PET/CT-Bilder von 49 thyreoidektomierte Patienten retrospektiv ausgewertet, um die mittleren Energiedosen in Schilddrüsenreste pro applizierte 131I-Aktivität zu ermitteln. Unter der Annahme einer hohen Ablationsrate bei einer Zieldosis von 300 Gy wurde der Anteil der Schilddrüsenreste, die mindestens 300 Gy deponiert haben, für Standardaktivitäten zwischen 0,37 bis 5,55 GBq errechnet. Betrug für verschiedene Aktivitäten die (absolute) Anteilsdifferenz weniger als 5%, so wurde die geringere Aktivität als gleichermaßen effektiv wie die höhere angesehen. Ergebnis: Insgesamt wurden 62 Schilddrüsenreste eingeschlossen. Der Median und die Spannbreite (innerhalb der Klammern) für die Energiedosis pro applizierte 131I-Aktivität betrugen 359 Gy/GBq (34–1825 Gy/GBq). Die Anteile der Schilddrüsenreste oberhalb der 300-Gy Schwellenwertgrenze in Abhängigkeit von der applizierten Therapieaktivität (innerhalb der Klammern) waren 60% (1,11 GBq), 76% (1,85 GBq), 79% (2,22 GBq) und 81–82% zwischen 2,59 und 3,70 GBq. Die Therapieaktivität von 1,11 GBq war deutlich weniger effektiv als die Therapieaktivitäten von 1,85 oder 2,22 GBq; Therapieaktivitäten zwischen 2,22 bis 3,70 GBq waren gleichermaßen effektiv. Schlussfolgerung: Auf der Grundlage des Modells und der eingeschlossenen Patientendaten kann vermutet werden, dass die niedrigste effektive Radioiodaktivität zur Ablation des Schilddrüsenrestes etwa 2,2 GBq beträgt. Die Ergebnisse dieser Arbeit können für die Planung prospektiver klinischer Studien von Nutzen sein.

 
  • References

  • 1 American Joint Committee on Cancer. AJCC cancer staging manual. Philadelphia: Lippincott; 1997
  • 2 Bohuslavizki KH, Brenner W, Lassmann S. et al. Quantitative salivary gland scintigraphy -- a recommended examination prior to and after radioiodine therapy. Nuklearmedizin 1997; 36: 103-109.
  • 3 Cooper DS, Doherty GM, Haugen BR. et al. Revised American Thyroid Association management guidelines for patients with thyroid nodules and differentiated thyroid cancer. Thyroid 2009; 19: 1167-1214.
  • 4 Doi SA, Engel JM, Onitilo AA. Total thyroidectomy followed by postsurgical remnant ablation may improve cancer specific survival in differentiated thyroid carcinoma. Clin Nucl Med 2010; 35: 396-399.
  • 5 Doi SA, Woodhouse NJ. Ablation of the thyroid remnant and 131I dose in differentiated thyroid cancer. Clin Endocrinol 2000; 52: 765-773.
  • 6 Doi SA, Woodhouse NJ, Thalib L, Onitilo A. Ablation of the thyroid remnant and I-131 dose in differentiated thyroid cancer: a meta-analysis revisited. Clin Med Res 2007; 5: 87-90.
  • 7 Fish SA, Basu S, Alavi A. et al. Comparison of efficacy of 2220 MBq versus 3700 MBq I-131 for ablation of thyroid remnant in patients with differentiated thyroid cancer. Q J Nucl Med Mol Imaging 2010; 54: 560-563.
  • 8 Hadjieva T. Quantitative approach to radioiodine ablation of thyroid remnants following surgery for thyroid cancer. Radiobiol Radiother (Berl) 1985; 26: 819-823.
  • 9 Hänscheid H, Lassmann M, Buck AK. et al. The limit of detection in scintigraphic imaging with I-131 in patients with differentiated thyroid carcinoma. Phys Med Biol 2014; 59: 2353-2368.
  • 10 International Commission on Radiological Protection. 1975. Report of the task group on reference man. ICRP Publication 23. Oxford: Pergamon Press;
  • 11 Jentzen W. An improved iterative thresholding method to delineate PET volumes using the delineation-averaged signal instead of the enclosed maximum signal. J Nucl Med Technol. 2014
  • 12 Jentzen W. Experimental investigation of factors affecting the absolute recovery coefficients in iodine-124 PET lesion imaging. Phys Med Biol 2010; 55: 2365-2398.
  • 13 Jentzen W, Freudenberg L, Bockisch A. Quantitative imaging of 124I with PET/CT in pretherapy lesion dosimetry. Effects impairing image quantification and their corrections. Q J Nucl Med Mol Imaging 2011; 55: 21-43.
  • 14 Jentzen W, Freudenberg L, Eising EG. et al. Optimized 124I PET dosimetry protocol for radioiodine therapy of differentiated thyroid cancer. J Nucl Med 2008; 49: 1017-1023.
  • 15 Jentzen W, Hobbs R, Stahl A. et al. Pre-therapeutic iodine-124 PET(/CT) dosimetry confirms low average absorbed doses per administered iodine-131 activity to the salivary glands in radioiodine therapy of differentiated thyroid cancer. Eur J Nucl Med Mol Imaging 2010; 37: 884-895.
  • 16 Jentzen W, Hoppenbrouwers J, van Leeuwen P. et al. Assessment of lesion response in the initial radioiodine treatment of differentiated thyroid cancer using 124I PET imaging. J Nucl Med 2014; 55: 1759-1765.
  • 17 Luster M, Clarke SE, Dietlein M. et al. Guidelines for radioiodine therapy of differentiated thyroid cancer. Eur J Nucl Med Mol Imaging 2008; 35: 1941-1951.
  • 18 Mallick U, Harmer C, Yap B. et al. Ablation with low-dose radioiodine and thyrotropin alfa in thyroid cancer. N Engl J Med 2012; 366: 1674-1685.
  • 19 Maxon HR, Englaro EE, Thomas SR. et al. Radioiodine-131 therapy for well-differentiated thyroid cancer - quantitative radiation dosimetric approach: outcome and validation in 85 patients. J Nucl Med 1992; 33: 1132-1136.
  • 20 Maxon HR, Thomas SR, Hertzberg VS. et al. Relation between effective radiation dose and outcome of radioiodine therapy for thyroid cancer. N Engl J Med 1983; 309: 937-941.
  • 21 Moldovan AS. Zieldosis-basierte Abschätzung der Ablationserfolge für das Schilddrüsenrestgewebe von Patienten mit differenziertem Schilddrüsenkarzinom bei Radioiodtherapieaktivitäten von 1,11 bis 3,70 GBq. Doctoral Thesis. University of Essen-Duisburg, Klinik für Nuklearmedizin; 2013
  • 22 Noaparast Z, Hosseinimehr SJ. Radioprotective agents for the prevention of side effects induced by radioiodine-131 therapy. J Future Oncol 2013; 9: 1145-1159.
  • 23 Rosenbaum-Krumme S, Nagarajah J, Ruhlmann M. et al. 124I-PET/CT images of differentiated thyroid cancer patients. Distinguishing lymph node metastases from thyroid remnants using kinetic quantities. Nuklearmedizin 2012; 51: 213-216.
  • 24 Schlumberger M, Catargi B, Borget I. et al. Strategies of radioiodine ablation in patients with low-risk thyroid cancer. N Engl J Med 2012; 366: 1663-1673.
  • 25 Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: The second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med 2005; 46: 1023-1027.