Next Article in Journal
Stereo Visual Servoing Control of a Soft Endoscope for Upper Gastrointestinal Endoscopic Submucosal Dissection
Next Article in Special Issue
A Topical Review on Enabling Technologies for the Internet of Medical Things: Sensors, Devices, Platforms, and Applications
Previous Article in Journal
Evolution of the Microrobots: Stimuli-Responsive Materials and Additive Manufacturing Technologies Turn Small Structures into Microscale Robots
Previous Article in Special Issue
Laser-Induced Intracellular Delivery: Exploiting Gold-Coated Spiky Polymeric Nanoparticles and Gold Nanorods under Near-Infrared Pulses for Single-Cell Nano-Photon-Poration
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Batch Fabrication of Microelectrode Arrays with Glassy Carbon Microelectrodes and Interconnections for Neurochemical Sensing: Promises and Challenges

1
Department of Biomedical Engineering, Louisiana Tech University, Ruston, LA 71272, USA
2
Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15260, USA
3
Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA 15261, USA
4
Institute for Micromanufacturing, Louisiana Tech University, Ruston, LA 15213, USA
5
McGowan Institute of Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219-3110, USA
*
Author to whom correspondence should be addressed.
Micromachines 2024, 15(2), 277; https://doi.org/10.3390/mi15020277
Submission received: 19 January 2024 / Revised: 7 February 2024 / Accepted: 13 February 2024 / Published: 15 February 2024
(This article belongs to the Special Issue Biosensors for Biomedical and Environmental Applications, Volume 2)

Abstract

:
Flexible multielectrode arrays with glassy carbon (GC) electrodes and metal interconnection (hybrid MEAs) have shown promising performance in multi-channel neurochemical sensing. A primary challenge faced by hybrid MEAs fabrication is the adhesion of the metal traces with the GC electrodes, as prolonged electrical and mechanical stimulation can lead to adhesion failure. Previous devices with GC electrodes and interconnects made of a homogeneous material (all GC) demonstrated exceptional electrochemical stability but required miniaturization for enhanced tissue integration and chronic electrochemical sensing. In this study, we used two different methods for the fabrication of all GC-MEAs on thin flexible substrates with miniaturized features. The first method, like that previously reported, involves a double pattern-transfer photolithographic process, including transfer-bonding on temporary polymeric support. The second method requires a double-etching process, which uses a 2 µm-thick low stress silicon nitride coating of the Si wafer as the bottom insulator layer for the MEAs, bypassing the pattern-transfer and demonstrating a novel technique with potential advantages. We confirmed the feasibility of the two fabrication processes by verifying the practical conductivity of 3 µm-wide 2 µm-thick GC traces, the GC microelectrode functionality, and their sensing capability for the detection of serotonin using fast scan cyclic voltammetry. Through the exchange and discussion of insights regarding the strengths and limitations of these microfabrication methods, our goal is to propel the advancement of GC-based MEAs for the next generation of neural interface devices.

1. Introduction

Carbon is considered the ideal material for electrochemical sensing and presents superior electrochemical stability [1,2,3,4,5]. For the last three decades, fast scan cyclic voltammetry (FSCV) at carbon fiber microelectrodes (CFEs) has been considered the gold standard for in vivo electrochemical detection of neurotransmitters, including dopamine (DA) [6,7,8], serotonin (5-HT) [1,9], and melatonin (MT) [10,11]. The sub-second temporal resolution (hundreds of milliseconds [12,13,14]) offered by FSCV is consistent with the rapid chemical fluctuations observed at neuronal synapses, facilitating real-time neurotransmitter detection. These fast scan rates can be alternated with high frequency electrophysiological recording at the same electrode [15,16].
Despite their effectiveness, CFEs are limited to a single electrode site and, even when using carbon fiber arrays, the restriction persists at one site per fiber. This limitation hinders the full potential of multiplexed analyses, which would allow simultaneous observations of electrical and chemical activities at multiple sites using a single device. Moreover, the fabrication process for CFE arrays can be intricate and time-consuming, which may impede scalability and widespread adoption [17,18,19].
On the other hand, thanks to the recent advances in material science and lithography microfabrication techniques, flexible microelectrode arrays (MEAs) with nanometer-thick metal thin-film electrodes integrated on micrometer-thick polymer substrates—such as polyimide, parylene C, and SU-8—have been developed to match the soft nature of the brain and minimize mechanical trauma and inflammation [20,21]. These flexible MEAs, along with subcellular dimension, can record electrophysiological neural activities at millisecond-scale temporal resolution and micrometer-scale spatial resolution and have been shown to seamlessly integrate with the neural tissue and improve recording longevity [22,23,24,25].
The use of carbon materials as a substitute of metal for conductive electrodes and interconnections in microfabricated flexible MEAs would enable multichannel electrochemical sensing and thus facilitate multimodal electrochemical and electrophysiological recordings [26,27]. The main challenge lies in the high temperature needed for carbon synthesis, incompatible with the use of polymer substrates [28]. Additionally, most of the carbon synthesis requires the use of a catalyst, such as nickel [29], iron [30], cobalt [31], and copper [32], which is potentially cytotoxic if not completely removed. Thanks to a pattern transfer technology, the integration of glassy carbon (GC) microelectrodes into flexible devices with metal interconnects has been achieved [33,34,35,36]. The GC microstructures are obtained from the pyrolysis of a pre-patterned polymeric precursor, such as SU-8, in an inert controlled atmosphere, avoiding risks of cytotoxicity and contamination and not requiring post-patterning.
GC MEAs, with GC microelectrodes and metal interconnections (hybrid MEAs), have shown highly sensitive neurotransmitter detection of DA and 5-HT [35] with good electrochemical fouling resistance [35] and high quality acute single-unit recordings [36,37]. Hybrid MEAs on thin flexible SU-8 substrates have also been demonstrated to reduce tissue damage and inflammation compared to stiff silicon MEAs, preserving a healthy neural tissue interface that can facilitate long-term sensing measurements [38].
The main concern faced with hybrid MEA fabrication is the adhesion between metal traces and GC electrodes, which is prone to failure upon prolonged electrical and mechanical stimulation. Using GC as a homogenous material for both electrodes and interconnects, without the need of adhesion layers, eliminates this concern. The first devices with GC electrodes and GC interconnects integrated on polyimide substrate have been fabricated by the Dr. Kassegne group and have shown outstanding electrochemical stability, demonstrating the capability of delivering charge-balance current pulsing over 3.5 billion cycles in an extended accelerated aging process lasting more than 1000 h, with no failure observed [21]. While this result holds promise for achieving stable neural interfaces, these devices require miniaturization [5] in order to reduce implantation injury and the inflammatory response for chronic electrochemical sensing.
Here, we show our progress in the fabrication of all GC-MEAs on thin flexible substrate while reducing dimensions to promote seamless tissue integration and long-lasting electrochemical recordings. We worked in parallel in the development of two microfabrication methods: (1) a double pattern-transfer photolithographic process, involving transfer-bonding on temporary polymeric support, similar to what was previously reported [21] and (2) a double-etching process, which uses a 2 µm-thick low stress low pressure chemical vapor deposition (LPCVD) nitride (Si3N4) coating of the Si wafer as the bottom insulator layer for the MEAs, bypassing the need for pattern-transfer and demonstrating a novel technique with potential advantages. This second process requires CF4 reactive ion etching of the Si3N4 to define the bottom shape of the device, after pyrolysis and patterning of the top MEAs insulation layer, and a purely chemical xenon difluoride (XeF2) etching of the exposed Si to release the Si3N4 insulated MEA from the Si wafer, taking advantage of the 200:1 Si versus Si3N4 selectivity [39,40].
We validated the feasibility of the proposed fabrication methods, by demonstrating the practical conductivity of 3 µm-wide 2 µm-thick GC traces and confirming the microelectrode functionality and discussed their respective strengths and limitations. Furthermore, we verified the ability of the GC microelectrodes to detect 5-HT using a FSCV N-shaped “modified Jackson waveform” (0.2 to 1.3 to −0.1 to 0.2 V) at a high scan rate (1000 V/s).
By sharing our progress in all GC-MEAs fabrication, we not only highlight the feasibility and potential of these methods but also encourage collaborative efforts and discussions within the community, fostering innovation and accelerating the development of novel neurotechnology applications. By sharing these results and insights, we hope to propel the development of GC-based MEAs for the next generation of neural interface devices.

2. Materials and Methods

2.1. Double Pattern-Transfer Microfabrication

Steps 1 and 2. A 4-in Si wafer with a 1 µm thick SiO2 layer (University Wafer Inc., Boston, MA, USA) was first cleaned with acetone, isopropanol, and deionized water (DI) sequentially. The wafer was then dried with a N2 spray gun, heated on a hot plate at 200 °C for 5 min, and treated with O2 plasma using a reactive ion etcher (RIE, MICRO-RIE 800, Technics Inc., Anaheim, CA, USA) for 90 s at 300 m Torr pressure and 150 W power. The cleaned wafer was spin-coated with SU-8 3010 (Kayaku Advanced Materials, Westborough, MA, USA) at 2000 rpm for 1 min and soft baked at 65 °C for 5 min and 95 °C for 5 min. Then, the wafer was exposed using a custom-made photomask and a MA/BA6 Mask/Bond Aligner (Süss MicroTec, Garching, Germany) with a dose of 350 mJ/cm2. After exposure, the wafer was first post-baked at 65 °C for 1 min and 95 °C for 3 min, then developed using SU-8 developer (Kayaku Advanced Materials, Westborough, MA, USA) for 1 min and cleaned with isopropanol and DI water. The patterned SU-8 was subsequently hard baked at 200 °C, 180 °C, and 150 °C for 5 min each and allowed to cool down below 65 °C. Pyrolysis of the negative SU-8 resist was performed in a high-temperature split tube furnace (STF 1200 Tube Furnace, Across International, Livingston, NJ, USA). The samples were heated to 900 °C with a temperature ramp-up at a rate of 3 °C/min, then maintained at 900 °C under 15 standard cubic centimeters per minute (sccm) N2 (Airgas, Pittsburgh, PA, USA) at 0.8 Torr for 60 min. The samples were then slowly cooled to room temperature. Step 3. After the pyrolysis, the wafer was cleaned with acetone, isopropanol, and DI water sequentially and treated with O2 plasma with RIE for 30 s at a pressure of 300 mTorr and 120 W power. The cleaned wafer was then spin-coated with SU-8 5 (Kayaku Advanced Materials, Westborough, MA, USA) at 3000 rpm for 1 min and then soft based at 65 °C for 3 min and 95 °C for 5 min. This SU-8 layer was patterned, using a dose of 300 mJ/cm2, to define the insulation layer. After a post-bake at 65 °C for 1 min and 95 °C for 3 min, the wafer was developed using the SU-8 developer. Finally, the patterned wafer was cleaned with isopropanol and DI water, hard baked at 200 °C, 180 °C, and 150 °C for 5 min each, and allowed to cool down below 65 °C. Step 4. After the hard baking, the wafer was treated with O2 plasma with RIE for 60 s at a pressure of 300 mTorr and 150 W power to improve the adhesion of the polydimethylsiloxane (PDMS, SYLGARD™ 184, Dow Corning, Midland, MI, USA) used as transfer substrate. Immediately after, the wafer was spin-coated with PDMS at 300 RPM for 20 s. PDMS was baked for 1 h at 80 degrees C and then allowed to cool down and stabilized overnight. Step 5 and 6. The 1st and 2nd layers of the MEAs were then transferred on the PDMS temporary transfer substrate using a wet chemical buffered oxide etching (BOE 7:1, Transene Co., Inc., Danvers, MA, USA) of SiO2 to release the PDMS from the Si substrate. Once the PDMS was completely released with the transferred MEAs, it was removed from the BOE bath and abundantly cleaned with DI water. Then, the standalone PDMS layer was flipped with the GC traces and interconnections of the MEAs facing up and bind to a Si wafer (temporary rigid support) to facilitate the next step, i.e., the insulation of the GC interconnections. The Si wafer was previously treated with O2 plasma with RIE for 90 s at a pressure of 300 mTorr and 150 W to facilitate the binding. Step 7. The temporary support was then spin-coated with SU-8 5 at 3000 rpm for 1 min and soft baked at 65 °C for 5 min and 95 °C for 5 min. Then, the wafer was exposed using a custom-made photomask and a MA/BA6 Mask/Bond Aligner with a dose of 350 mJ/cm2. After exposure, the wafer was first post-baked at 65 °C for 1 min and 95 °C for 3 min, then developed using a SU-8 developer (Kayaku Advanced Materials, Westborough, MA, USA) for 1 min, and then cleaned with isopropanol and DI water. The patterned SU-8 was subsequently hard baked at 200 °C, 180 °C, and 150 °C for 5 min each and allowed to cool down below 65 °C. Step 8. Finally, the insulated MEAs were gently pilled off from the PDMS.

2.2. Double Dry-Etching Microfabrication

Steps 1, 2, and 3: A 4-in Si wafer with a 2 µm-thick low stress LPCVD Si3N4 layer (University Wafer Inc., Boston, MA, USA) was first cleaned with acetone, isopropanol, and deionized water (DI) sequentially. The wafer was then dried with a N2 spray gun, heated on a hot plate at 200 °C for 5 min, and treated with O2 plasma using a reactive ion etcher (RIE, MICRO-RIE 800, Technics Inc., Anaheim, CA, USA) for 90 s at 300 mTorr pressure and 150 W power. These 3 steps are the same of the step 1–3 of the double pattern-transfer microfabrication. Briefly, the SU-8 precursor was patterned on the Si3N4-coated Si wafer followed by pyrolysis to obtain GC electrodes and interconnections and the SU-8 insulation layer was lithography patterned to define the device layout. Step 4. After the hard baking of the SU-8, the devices were protected with a sacrificial hard mask. First, the wafer was treated with O2 plasma with RIE for 60 s at a pressure of 300 mTorr and 100 W power and then spin-coated with a S1318 positive photoresist (MICROPOSIT™ S1800® G2 Series Photoresists, Kayaku Advanced Materials, Westborough, MA, USA) at 800 rpm for 1 min and baked at 115 °C for 1 min. After soft baking, the wafer was exposed and patterned with a dose of 500 mJ/cm2, then developed using MF-321 developer (MICROPOSIT™, Kayaku Advanced Materials, Westborough, MA, USA), cleaned with water, rinsed, and dried by N2 gas flow. Step 5. Then the wafer was exposed to CF4 reactive ion etching (RIE, 220 mTorr pressure and 200 W power) to etch the 2 µm Si3N4 layer, where not protected, leaving the Si exposed. Step 6. To release the Si3N4-insulated MEA from the Si wafer, the exposed Si was etched using a purely chemical xenon difluoride (XeF2) etching with pressure P(XeF2) of 3.5 mT at room temperature, using a xenon difluoride etching tool (Xetch X.3.B, Xactix Inc., River Park Commons, PA, USA). Step 7. After the insulated MEAs were released, the sacrificial protective layer was easily removed with acetone.

2.3. Morphological and Chemical Characterization

Scanning electron microscope (SEM) imaging and elemental analysis of surfaces in field-emission electron microscopy were performed using energy dispersive spectroscopy (EDS) to identify and quantify all present elements using a HITACHI S-4800 field-emission electron microscope with a Bruker (Xflash 6160) EDS attachment (HITACHI Global, Irvine, CA, USA). High resolution optical imaging was performed using a VK-X150 3D scanning confocal microscope (Keyence America, Itasca, IL, USA).

2.4. Electrochemical Characterization

To verify the electrode functionality, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were performed in 1 × phosphate-buffered saline (PBS, Sigma Aldrich, St. Louis, MO, USA) in a three-electrode electrochemical cell set-up with a platinum counter electrode and an Ag/AgCl wire reference electrode, using a potentiostat/galvanostat (Autolab, Metrohm, Riverview, FL, USA). EIS was performed by superimposing a sine wave (10 mV RMS amplitude) onto the open circuit potential while varying the frequency from 1 to 105 Hz. During the CV tests, the working electrode potential was swept between 1.3 and −0.6 V vs. Ag/AgCl at a scan rate of 100 mV/s.
Additionally, the sheet resistance of the GC traces (3 µm wide and 5 mm long) was measured on a Si substrate in comparison with gold traces of the same width and length. To do so, 3 µm wide and 5 mm long traces (Au and GC) were fabricated on a silicon substrate together with 3 × 3 mm pads to provide reliable connection points for the measurement probes. Then, the resistance was measured using EIS in a two-terminal setup (in the air) and the sheet resistance was calculated knowing the thickness, length, and width of the traces.

2.5. Fast Scan Cyclic Voltammetry Sensing

Fast scan cyclic voltammetry (FSCV) measurements of 5-HT were collected using a FSCV Wave Neuro potentiostat connected to a Flow Cell System (Pine Research, Durham, NC, USA) to validate the GC microelectrode sensitivity and analyzed using HDCV software (University of North Carolina at Chapel Hill, Chapel Hill, NC, USA). The electrode was scanned using a modified N-shaped waveform (0.2 to 1.3 to −0.1 to 0.2 V) at 10 Hz and 1000 V/s scan rate. 5-HT was identified by inspection of the background-subtracted cyclic voltammograms. Electrodes were calibrated using 0.1–1.5 μM 5-HT concentrations dissolved in 1× PBS. The different concentrations were diluted starting from freshly prepared 1 mM 5-HT solutions. Calibration was performed in a flow cell Flow Cell System (Pine Research, Durham, NC, USA). Flow through the system at 60 mL/h was driven with a syringe pump.

3. Results and Discussions

3.1. Patterning and Carbonization of GC Electrodes and Interconnections

All GC-MEAs were successfully developed following the two fabrication processes schematically described in Figure 1 and Figure 2. The first step, common to both the methods, is the patterning and carbonization of SU-8 to obtain miniaturized GC features. Different MEA layouts were incorporated into the same photomasks to test different trace spacing (10 to 20 µm), microelectrode center-to-center distances (100 to 250 µm), microelectrode shapes (30 to 40 µm diameter circular or 55 × 25 µm oval), microelectrode numbers (5 to 8), and shank widths (90 to 140 µm). Supplementary Figure S1 reports an example of batch-fabricated GC microelectrodes and interconnections.
Figure 3 shows the results from the patterning and carbonization of 3 µm-wide GC traces (a–c), 30 µm diameter microelectrodes (d), 300 µm pads (e), and different size aligner markers (f), with features down to 3 µm, for high alignment accuracy. The sheet resistance of the 3 µm wide and 5 mm long GC traces was measured on Si substrate, in comparison with gold traces of the same width and length. The value obtained is 1.21 ± 0.26 Ω/sq, which is the same order of magnitude as gold traces of the same dimension (0.22 ± 0.01 Ω/sq). Thus, we do not expect signal attenuation due to the large serial resistance of the GC traces. These values have been obtained for GC traces approximately 2 µm thick. We observed that during the pyrolysis, the hard-baked SU-8 precursor experienced about 70% shrinkage. This factor should be considered for the choice of SU-8 viscosity and spinning rate during the photolithography. Controlling these parameters effectively is crucial for achieving the desired thickness and uniformity of the SU-8 layer, which ultimately determines the dimensions and properties of the fabricated GC traces.

3.1.1. Double Pattern-Transfer Microfabrication

Figure 4a and Figure S2 report standalone PDMS layers (250–300 µm-thick) containing the transferred all GC-MEAs, after being released from the SiO2 wafer using chemical-buffered oxide etching. This step involves separating the PDMS layer, along with all GC-MEAs, from the SiO2 wafer, thus exposing the side of the GC electrode, traces, and interconnections that still need to be insulated. The precision of the aligner marks on PDMS, reported in Figure 4b, highlights the success of one of the most critical steps, i.e., the transferring of the first and second layers of the MEAs onto the PDMS temporary transfer substrate. Both SU-8 and GC have shown a good adhesion to PDMS, after the oxygen plasma treatment, achieving proper bonding. This adhesion ensures that the layers (SU-8 and GC) firmly attach to the PDMS substrate, which is critical for maintaining structural integrity and functionality throughout the fabrication process. PDMS is highly elastic and flexible, making it ideal for replicating intricate patterns with high fidelity and conforming to various shapes, thus facilitating this delicate transferring process [41]. Additionally, PDMS presents good chemical inertness; it does not react with most chemicals [42] and it was able to sustain BOE oxide etching. Subsequently, the standalone PDMS layer, with the GC traces and interconnections of the MEAs facing up, was transfer-bonded to a rigid silicon substrate to offer temporary support, as illustrated in Figure 4c. The use of a rigid silicon substrate facilitates precise alignment for the next step, which involves insulating the GC interconnections while ensuring well-aligned openings on the pads and electrodes, crucial to ensure reliable electrical connections and electrochemical readings. Figure 4d,e shows the magnification of the microelectrodes and connecting pads post-insulation, highlighting the aligned openings in the final insulation layer. PDMS also presents low free surface energy, which favors the peel-off of the finalized MEAs from the PDMS [42,43]. Furthermore, it is biocompatible and non-toxic, minimizing any concern of possible contaminations. Figure 4f shows a finally insulated all GC-MEA while peeling off from the PDMS. This MEA is composed of a singular shank (140 µm wide and ~8 µm thick) with five oval GC electrodes.
Figure 4g shows the finally insulated all GC-MEA, with the corresponding magnification of the shank, connected to the custom-made printed circuit board (PCB) using a zero-insertion force (ZIF) connector, to be interfaced with the potentiostat for characterization and sensing. At the tip of the shank, an anchor hole was patterned in the SU-8 insulation layers to facilitate the insertion of a 50 µm tungsten shuttle that will enable the handling and penetration of the probes into the brain, as previously reported. This device is composed of a singular shank (120 µm wide and ~8 µm thick) with five circular GC electrodes 30 µm in diameter. The total length of the shank is 5 mm to easily target the deep brain region of the mice [38].
These results demonstrate the feasibility of the double pattern-transfer photolithographic process for the fabrication of all GC-MEAs on flexible SU-8 substrate with miniaturized features. However, limitations emerged due to the complexity of this process, particularly regarding further miniaturization and scalability. The PDMS transfer method was effective in transferring all GC-MEAs but handling large PDMS sheets posed difficulties during batch fabrication, limiting the fabrication to small areas. Indeed, the positioning of a 300 µm-thick standalone PDMS of a larger area on the silicon resulted in micro-folding and shifting, which significantly impact the alignment of devices, limiting the number of devices that can be processed at once. Currently, only small sections of PDMS can be successfully used, as observed in Figure 4a. Thicker PDMS layers have shown poor adherence and bonding to the rigid Si substrate. However, optimizing the deposition process and tailoring PDMS properties are crucial steps to further enhance its adherence and bonding to the rigid silicon substrate. Adjusting parameters such as the curing temperature, time, or surface treatments for both PDMS and the silicon substrate could significantly improve their compatibility [44,45]. Due to the advantageous properties of the PDMS, exploring a mold-based approach for thicker and more stable PDMS transfer seems like a viable solution to consider. Using a higher crosslinker concentration, adding modifying agent or reinforcement fillers can increase the PDMS stiffness [45,46]. Employing a more rigid and flat-molded PDMS of optimized thickness might eliminate the need for additional rigid support during the transfer process. Thorough testing and optimization will be essential to ensure that the modified PDMS maintains its advantageous properties while addressing the challenges encountered during fabrication. Moreover, considering alternative temporary transfer materials could be beneficial. These materials should strike a balance between various mechanical and chemical properties based on the process needs, such as conforming and bonding to SU-8 of different shapes, chemical inertness, and easy removal. These discussed approaches—fine-tuning PDMS properties, exploring mold-based transfers, and investigating alternative transfer materials—can potentially address the challenges faced in handling larger PDMS sheets and improve the scalability and efficiency of batch fabrication.

3.1.2. Double Dry-Etching Microfabrication

Here, an alternative microfabrication method that does not require a double pattern-transfer technique to develop all GC-MEAs with miniaturized features was also developed and tested. In this process, referred to as double dry-etching microfabrication, the fabrication of the GC and insulation layer was repeated on 2 µm-thick low-stress LPCVD nitride Si3N4 wafers. Briefly, the SU-8 precursor was patterned on the Si3N4 wafer followed by pyrolysis to obtain GC electrodes and interconnections with trace width and thickness optimized to ensure practical conductivity. Second, the SU-8 insulation of the device was patterned and hard-backed. Subsequently, the MEAs were protected with a sacrificial hard mask to preserve the insulation and GC contact in the subsequent CF4 RIE etching process of the non-protected Si3N4 covering the wafer. This process was able to selectively etch away the Si3N4 while preserving the insulated GC-MEA features. The Si3N4 etching rate was 108.28 ± 7.9 nm/min, taking 20 min to completely expose all the underneath Si substrate. At this point, the GC traces, microelectrodes, and interconnections were insulated on the bottom from Si3N4 and on the top by SU-8 and they were required to be released by the Si substrate.
Si3N4 has been extensively used as an insulator substrate for microfabricated multielectrode arrays and it has been shown to offer several advantages such as biocompatibility, good electrical insulation, mechanical robustness, and chemical stability [47,48,49]. Despite Si3N4 having an elastic modulus of hundreds of GPa [50,51], significantly higher compared to polymeric substrates, such as SU-8 [52] and polyimide [53], the fabrication of ultrathin semiconductor membranes allows silicon-based electronics to achieve extraordinary flexibility [54,55]. Moreover, ultrathin silicon layers transferred onto flexible polymers can potentially adapt to the flexibility offered by polymers [56,57].
At this stage, a purely chemical XeF2 etching was used to release all GC-MEAs from the Si substrate, involving the use of XeF2 gas to selectively remove Si in a uniform manner. XeF2 gas selectively reacts with Si atoms on the surface, without the need for a liquid phase, leading to the removal of silicon atoms in the form of volatile silicon fluoride (SiF4) [39]. The gas adsorbs uniformly onto the silicon surface, initiating isotropic removal in all directions, enabling precise depth etching without damaging surrounding materials. XeF2’s selectivity ensures minimal reactivity towards materials like SiO2, SiC, Si3N4, and photoresist, preserving their integrity during the silicon etching process [40,58]. In this work, using a pressure of 3.5 mTorr at room temperature, the Si etching rate was 1.254 ± 0.166µm/min. The process demonstrated high selectivity, allowing precise etching of the Si substrate while maintaining the integrity of Si3N4 layers, as observed performing EDS analysis (Table 1, Figure 5). Previous studies under similar conditions did not observe etching of SiO2 or Si3N4, indicating an extremely large selectivity between silicon and its compounds [39,40]. Figure 5 reports the SEM images with elemental analysis of the surface of all GC-MEAs released using isotropic XeF2 etching (side insulated with Si3N4). The elemental analyses conducted using energy dispersive X-ray spectroscopy (EDS) confirmed a consistent and uniform presence of Si and N along the shank of the MEAs and the presence of carbon in the areas where the focus of the analysis was on the carbon tape of the stub (where the MEAs are positioned for imaging).
Overall, our results suggest that the double dry-etching microfabrication offers a promising method for producing all GC-MEAs on flexible substrates with miniaturized features. Its key advantage lies in circumventing the need for double pattern transfer, streamlining the fabrication process significantly and reducing potential errors associated with transferring and aligning micrometer feature patterns. This approach will facilitate further miniaturization of all GC neural probes. With further optimization and refinement, this technique could lead to more reliable and scalable manufacturing of all GC-MEAs and carbon-based neural interface technologies.
However, there are some challenges that need to be discussed associated with maintaining process control [59]. Maintaining high selectivity between silicon and silicon nitride during XeF2 etching is crucial for ensuring the reliability and functionality of devices. Therefore, different factors that can influence the etch rate and selectivity should be carefully considered during the design and optimization of the etching process, including the temperature, pressure, exposure time to XeF2 gas, addition of gases, such as hydrogen, and process variability [59]. Additionally, controlling the level of XeF2 supplied to the chamber is crucial in the XeF2 etching processes. The amount of XeF2 introduced significantly influences the etch rate and is a major source of variability. The amount of solid XeF2 within the bubbler determines the initial supply, which slowly decreases over time as the etching process continues. Running etch processes in rapid succession can deplete the available XeF2 more quickly. The etching rate is also affected by the quantity of silicon in the chamber. More silicon means a faster consumption rate, impacting the etch rate [60]. To achieve a reasonable and consistent etch rate, managing these factors becomes critical. Limiting the batch fabrication to smaller pieces of wafer at a time could mitigate this issue but restrict the scalability.
Transitioning to industrial-grade etching equipment might offer a potential solution to some challenges associated with process control, enabling more precise regulation of parameters like gas flow rates, pressure, and substrate handling. These systems are designed to manage larger quantities of substrates while maintaining more stable and controlled etching conditions, potentially addressing the challenges faced with fluctuating etch rates due to XeF2 supply variability [61]. However, despite the potential benefits, it is essential to consider the associated safety, environmental impact, cost, and availability of industrial equipment in making such a transition. Striking a balance between the benefits and limitations of XeF2 etching requires comprehensive strategies that consider process optimization, safety precautions, cost-effectiveness, and strict adherence to safety protocols. Technological and research progress seeks to address these limitations while optimizing the effectiveness of XeF2 etching in microfabrication applications.

3.2. Electrochemical Characterization and Sensing

EIS measurements (Figure 6a) resulted in impedance values of 30µm diameter GC microelectrodes (82.622 ± 19.218 @ 1 kHz), comparable with the GC microelectrodes of hybrid MEAs of a similar size [36]. The cyclic voltammogram revealed a wide electrochemical window extending up to 1.3 V without inducing hydrolysis reactions. This broad potential range should allow FSCV detection without compromising the background stability. The measurements have been performed using microelectrodes from different MEAs fabricated using both methods.
Finally, GC microelectrodes of all GC-MEAs were subjected to FSCV measurement for the detection of 5-HT in the 0.1–1.5 μM concentration range, using an N-shaped “modified” Jackson waveform (0.2 to 1.3 to −0.1 to 0.2 V) at a 1000 V/s high scan rate. This waveform should exclude the most likely interference from DA and other catecholamines because the scan rate has been shown to be too fast for DA to undergo the redox reaction using GC microelectrodes [35]. Such an N-shaped waveform has also been shown to be highly effective in reducing electrode fouling [35,62]. The GC microelectrodes exhibited high sensitivity to 5-HT (122.94 ± 4.36 nA/μM) in the concentration range of 0.1–1.5 μM, with a linear (r2 > 0.99, Figure 6b) response. Figure 6c shows the background subtracted CVs corresponding to the considered concentration range, demonstrating clear oxidation peaks at 0.9 V and reduction peaks at 0.15 V vs. Ag/AgCl. Figure 6d illustrates a representative color plot corresponding to the detection of a 100 nM bolus injection of 5-HT, underlining the possibility to clearly identify 5-HT reduction and oxidation peaks in the concentration range usually detectable in the mouse brain using FSCV [63,64]. Figure 6e,f report color plots corresponding to a response to a much higher 5-HT concentration of 1.5 μM. No background drift was observed during multiple repetitions of 1.5 μM 5-HT bolus injections over a 5-min FSCV collection in 1× PBS (Figure 6f), underlining good stability of the background current. These results collectively confirmed the GC-MEA functionality and capability for selective and stable electrochemical detection of 5-HT. The findings highlight the potential for further comprehensive testing, both in vitro and in vivo, to assess electrochemical and sensing stability for chronic implants.
5-HT imbalance has been shown to be implicated in various neurological and psychiatric disorders, such as depression, anxiety, chronic pain, and impulse control disorders but the underlying mechanisms are still unclear. Thus, the potential of 5-HT measurement, in combination with electrophysiological recording, would enable a deeper understanding of the role of 5-HT in these conditions and consequently improve the efficacy of specific pharmacological treatments.

4. Conclusions

This work showcases the successful development of “all” GC-MEAs on thin flexible substrates aimed at enhancing tissue integration and ensuring long-lasting electrochemical recordings.
We pursued two parallel paths in fabrication techniques:
(1)
A double pattern-transfer photolithographic process, involving transfer-bonding on temporary polymeric support, and (2) a double-etching process which uses the 2 µm-thick low stress LPCVD nitride coating of the Si wafer as bottom insulator layer for the MEAs, bypassing pattern transfer and demonstrating a novel technique with potential advantages;
(2)
A novel double-etching process utilizing a 2 µm-thick low-stress LPCVD nitride coating as the bottom insulator layer, bypassing pattern transfer and offering potential advantages. This latter technique involves CF4 reactive ion etching of Si3N4 to define the bottom device shape, followed by a chemical XeF2 etching to release the Si3N4-insulated MEA from the Si wafer, taking advantage on high Si versus Si3N4 selectivity.
We presented step-by-step fabrication results and discussed the advantages and limitations of the two fabrication techniques. We demonstrated the practical conductivity of 3 µm-wide 2 µm-thick GC traces and validated the microelectrode functionality. Utilizing FSCV with an N-shaped “modified Jackson waveform” at a high scan rate (1000 V/s), we successfully detected 5-HT, confirming the sensing capability of the GC microelectrodes.
Presenting our results in all GC-MEAs fabrication not only highlights the feasibility and potential of these methods but also encourages collaborative efforts and discussions within the community, fostering innovation and accelerating the development of novel neurotechnology applications. The discussions of the respective strengths and limitations of the two fabrication methods will undoubtedly provide crucial insights for refining and developing the next generation of neurotechnology devices, leading to improved designs and functionalities that can further advance the field. Optimization of this new class of neural devices is urgently needed. By sharing our progress, we hope to encourage collaborative efforts and discussions within the community, accelerating their development and characterization.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/mi15020277/s1, Figure S1: GC microelectrode and interconnection on a 4-inch wafer. Different MEA layouts were incorporated into the same photomasks to test different trace spacing (10 to 20 µm), microelectrode center-to-center distances (100 to 250 µm), microelectrode shape (30 to 40 µm diameter circular or 55 × 25 µm oval) and microelectrode numbers (5 to 8), shank width (90 to 140 µm). Figure S2: Double Pattern Transfer Fabrication: (a,b) optical images of two standalone PDMS layers (300 µm thick) containing the transferred all GC-MEAs, after being released from the SiO2 wafer using a chemical buffered oxide etching.

Author Contributions

Conceptualization, E.C. and X.T.C.; methodology, E.C., E.-B.A.F., M.Y.P., B.W. and D.B.; validation, E.C., E.-B.A.F., M.Y.P., B.W., D.B., Q.C., D.R.R. and A.M.B.; formal analysis, data curation, E.C.; writing—original draft preparation, E.C.; writing—review and editing, E.-B.A.F., M.Y.P. and X.T.C.; visualization, E.C.; supervision, E.C. and X.T.C.; project administration, E.C.; funding acquisition, E.C. and X.T.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Institute of Heath grants R01NS126454 and R21MH128803 to Castagnola and R01NS110564 and R21NS123937 to Cui.

Data Availability Statement

The data presented in this study are available on request from the corresponding author ([email protected]).

Acknowledgments

We would like to thank Arden Moore and Deborah Wood of the Institution for Micromanufacturing at Louisiana Tech University for the use of their facilities and technical support.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Puthongkham, P.; Venton, B.J. Recent Advances in Fast-Scan Cyclic Voltammetry. Analyst 2020, 145, 1087–1102. [Google Scholar] [CrossRef]
  2. Yang, C.; Denno, M.E.; Pyakurel, P.; Venton, B.J. Recent trends in carbon nanomaterial-based electrochemical sensors for biomolecules: A review. Anal. Chim. Acta 2015, 887, 17–37. [Google Scholar] [CrossRef]
  3. McCreery, R.L. Advanced carbon electrode materials for molecular electrochemistry. Chem. Rev. 2008, 108, 2646–2687. [Google Scholar] [CrossRef]
  4. Vomero, M.; Castagnola, E.; Ciarpella, F.; Maggiolini, E.; Goshi, N.; Zucchini, E.; Carli, S.; Fadiga, L.; Kassegne, S.; Ricci, D. Highly stable glassy carbon interfaces for long-term neural stimulation and low-noise recording of brain activity. Sci. Rep. 2017, 7, 40332. [Google Scholar] [CrossRef] [PubMed]
  5. Nimbalkar, S.; Castagnola, E.; Balasubramani, A.; Scarpellini, A.; Samejima, S.; Khorasani, A.; Boissenin, A.; Thongpang, S.; Moritz, C.; Kassegne, S. Ultra-capacitive carbon neural probe allows simultaneous long-term electrical stimulations and high-resolution neurotransmitter detection. Sci. Rep. 2018, 8, 6958. [Google Scholar] [CrossRef] [PubMed]
  6. Venton, B.J.; Cao, Q. Fundamentals of fast-scan cyclic voltammetry for dopamine detection. Analyst 2020, 145, 1158–1168. [Google Scholar] [CrossRef] [PubMed]
  7. Budai, D. Electrochemical responses of carbon fiber microelectrodes to dopamine in vitro and in vivo. Acta Biol. Szeged. 2010, 54, 155–160. [Google Scholar]
  8. Bath, B.D.; Michael, D.J.; Trafton, B.J.; Joseph, J.D.; Runnels, P.L.; Wightman, R.M. Subsecond adsorption and desorption of dopamine at carbon-fiber microelectrodes. Anal. Chem. 2000, 72, 5994–6002. [Google Scholar] [CrossRef] [PubMed]
  9. Ou, Y.; Buchanan, A.M.; Witt, C.E.; Hashemi, P. Frontiers in electrochemical sensors for neurotransmitter detection: Towards measuring neurotransmitters as chemical diagnostics for brain disorders. Anal. Methods 2019, 11, 2738–2755. [Google Scholar] [CrossRef]
  10. Hensley, A.L.; Colley, A.R.; Ross, A.E. Real-time detection of melatonin using fast-scan cyclic voltammetry. Anal. Chem. 2018, 90, 8642–8650. [Google Scholar] [CrossRef]
  11. Castagnola, E.; Robbins, E.M.; Woeppel, K.M.; McGuier, M.; Golabchi, A.; Taylor, I.M.; Michael, A.C.; Cui, X.T. Real-time fast scan cyclic voltammetry detection and quantification of exogenously administered melatonin in mice brain. Front. Bioeng. Biotechnol. 2020, 8, 602216. [Google Scholar] [CrossRef]
  12. Jacobs, C.B.; Ivanov, C.B.; Nguyen, M.D.; Zestos, A.G.; Venton, B.J. High temporal resolution measurements of dopamine with carbon nanotube yarn microelectrodes. Anal. Chem. 2014, 86, 5721–5727. [Google Scholar] [CrossRef]
  13. Keithley, R.B.; Takmakov, P.; Bucher, E.S.; Belle, A.M.; Owesson-White, C.A.; Park, J.; Wightman, R.M. Higher sensitivity dopamine measurements with faster-scan cyclic voltammetry. Anal. Chem. 2011, 83, 3563–3571. [Google Scholar] [CrossRef] [PubMed]
  14. Robinson, D.L.; Venton, B.J.; Heien, M.L.; Wightman, R.M. Detecting subsecond dopamine release with fast-scan cyclic voltammetry in vivo. Clin. Chem. 2003, 49, 1763–1773. [Google Scholar] [CrossRef] [PubMed]
  15. Bucher, E.S.; Wightman, R.M. Electrochemical analysis of neurotransmitters. Annu. Rev. Anal. Chem. 2015, 8, 239–261. [Google Scholar] [CrossRef] [PubMed]
  16. Owesson-White, C.; Belle, A.M.; Herr, N.R.; Peele, J.L.; Gowrishankar, P.; Carelli, R.M.; Wightman, R.M. Cue-evoked dopamine release rapidly modulates D2 neurons in the nucleus accumbens during motivated behavior. J. Neurosci. 2016, 36, 6011–6021. [Google Scholar] [CrossRef] [PubMed]
  17. Schwerdt, H.N.; Zhang, E.; Kim, M.J.; Yoshida, T.; Stanwicks, L.; Amemori, S.; Dagdeviren, H.E.; Langer, R.; Cima, M.J.; Graybiel, A.M. Cellular-scale probes enable stable chronic subsecond monitoring of dopamine neurochemicals in a rodent model. Commun. Biol. 2016, 1, 1–11. [Google Scholar] [CrossRef] [PubMed]
  18. Schwerdt, H.N.; Shimazu, H.; Amemori K-i Amemori, S.; Tierney, P.L.; Gibson, D.J.; Hong, S.; Yoshida, T.; Langer, R.; Cima, M.J. Long-term dopamine neurochemical monitoring in primates. Proc. Natl. Acad. Sci. USA 2017, 114, 13260–13265. [Google Scholar] [CrossRef] [PubMed]
  19. Patel, P.R.; Zhang, H.; Robbins, M.T.; Nofar, J.B.; Marshall, S.P.; Kobylarek, M.J.; Kozai, T.D.; Kotov, N.A.; Chestek, C.A. Chronic in vivo stability assessment of carbon fiber microelectrode arrays. J. Neural Eng. 2016, 13, 066002. [Google Scholar] [CrossRef] [PubMed]
  20. Agorelius, J.; Tsanakalis, F.; Friberg, A.; Thorbergsson, P.T.; Pettersson, L.M.E.; Schouenborg, J. An array of highly flexible electrodes with a tailored configuration locked by gelatin during implantation—Initial evaluation in cortex cerebri of awake rats. Front. Neurosci. 2015, 9, 331. [Google Scholar] [CrossRef]
  21. Kassegne, S.K.; Nimbalkar, S.; Balasubramani, A. Glassy Carbon Probe and Microfabrication Method. U.S. Patent No. US16/642,854, 23 January 2024. [Google Scholar]
  22. Liu, J. Syringe injectable electronics. In Biomimetics through Nanoelectronics; Springer: Berlin/Heidelberg, Germany, 2018; pp. 65–93. [Google Scholar]
  23. Luan, L.; Wei, X.; Zhao, Z.; Siegel, J.J.; Potnis, O.; Tuppen, C.A.; Lin, S.; Kazmi, S.; Fowler, R.A.; Holloway, S.; et al. Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration. Sci. Adv. 2017, 93, e1601966. [Google Scholar] [CrossRef] [PubMed]
  24. Zhao, Z.; Li, X.; He, F.; Wei, X.; Lin, S.; Xie, C. Parallel, minimally-invasive implantation of ultra-flexible neural electrode arrays. J. Neural Eng. 2019, 16, 035001. [Google Scholar] [CrossRef]
  25. Xie, C.; Liu, J.; Fu, T.-M.; Dai, X.; Zhou, W.; Lieber, C.M. Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes. Nat. Mater. 2015, 14, 1286–1292. [Google Scholar] [CrossRef] [PubMed]
  26. Zachek, M. Development of Carbon-MEMS Based Device for the In Vivo Electrochemical Detection of Neurotransmitter Fluctuations; North Carolina State University: Raleigh, NC, USA, 2010. [Google Scholar]
  27. Castagnola, E.; Vahidi, N.W.; Nimbalkar, S.; Rudraraju, S.; Thielk, M.; Zucchini, E.; Cea, C.; Carli, S.; Gentner, T.Q.; Ricci, D.; et al. In vivo dopamine detection and single unit recordings using intracortical glassy carbon microelectrode arrays. MRS Adv. 2018, 3, 1629. [Google Scholar] [CrossRef]
  28. Yang, C.; Jacobs, C.B.; Nguyen, M.D.; Ganesana, M.; Zestos, A.G.; Ivanov, I.N.; Puretzky, A.A.; Rouleau, C.M.; Geohegan, D.B.; Venton, B.J. Carbon nanotubes grown on metal microelectrodes for the detection of dopamine. Anal. Chem. 2016, 88, 645–652. [Google Scholar] [CrossRef]
  29. Castagnola, E.; Ansaldo, A.; Fadiga, L.; Ricci, D. Chemical vapour deposited carbon nanotube coated microelectrodes for intracortical neural recording. Phys. Status Solidi B 2010, 247, 2703–2707. [Google Scholar] [CrossRef]
  30. Ci, L.; Rao, Z.; Zhou, Z.; Tang, D.; Yan, X.; Liang, Y.; Liu, D.; Yuan, H.; Zhou, W.; Wang, G. Double wall carbon nanotubes promoted by sulfur in a floating iron catalyst CVD system. Chem. Phys. Lett. 2002, 359, 63–67. [Google Scholar] [CrossRef]
  31. Huang, Z.; Wang, D.; Wen, J.; Sennett, M.; Gibson, H.; Ren, Z. Effect of nickel, iron and cobalt on growth of aligned carbon nanotubes. Appl. Phys. A 2002, 74, 387–391. [Google Scholar] [CrossRef]
  32. Antonova, I.V. Chemical vapor deposition growth of graphene on copper substrates: Current trends. Phys. Uspekhi 2013, 56, 1013. [Google Scholar] [CrossRef]
  33. Kassegne, S.; Vomero, M.; Gavuglio, R.; Hirabayashi, M.; Özyilmaz, E.; Nguyen, S.; Rodriguez, J.; van Niekerk, P.; Khosla, A. Electrical impedance, electrochemistry, mechanical stiffness, and hardness tunability in glassy carbon MEMS μECoG electrodes. Microelectron. Eng. 2015, 133, 36–44. [Google Scholar] [CrossRef]
  34. Kassegne, S.; Vomero, M.; van Niekerk, P.; Hirabayashi, M.; Perez-Gonzalez, V.; Pramanick, B.; Madou, M. Glassy Carbon Microelectrodes for Neural Signal Sensing and Stimulation. In Book 2 Carbon-The Next Silicon? Applications; Momentum Press: New York, NY, USA, 2016; pp. 101–122. [Google Scholar]
  35. Castagnola, E.; Thongpang, S.; Hirabayashi, M.; Nava, G.; Nimbalkar, S.; Nguyen, T.; Lara, S.; Oyawale, A.; Bunnell, J.; Moritz, C.; et al. Glassy carbon microelectrode arrays enable voltage-peak separated simultaneous detection of dopamine and serotonin using fast scan cyclic voltammetry. Analyst 2021, 146, 3955–3970. [Google Scholar] [CrossRef]
  36. Castagnola, E.; Robbins, E.M.; Wu, B.; Pwint, M.Y.; Garg, R.; Cohen-Karni, T.; Cui, X.T. Flexible glassy carbon multielectrode array for in vivo multisite detection of tonic and phasic dopamine concentrations. Biosensors 2022, 12, 540. [Google Scholar] [CrossRef]
  37. Vahidi, N.W.; Rudraraju, N.W.; Castagnola, E.; Cea, C.; Nimbalkar, S.; Hanna, R.; Arvizu, R.; Dayeh, S.A.; Gentner, T.Q.; Kassegne, S. Epi-Intra neural probes with glassy carbon microelectrodes help elucidate neural coding and stimulus encoding in 3D volume of tissue. J. Neural Eng. 2020, 17, 046005. [Google Scholar] [CrossRef]
  38. Castagnola, E.; Robbins, E.M.; Krahe, D.D.; Wu, B.; Pwint, M.Y.; Cao, Q.; Cui, X.T. Stable in-vivo electrochemical sensing of tonic serotonin levels using PEDOT/CNT-coated glassy carbon flexible microelectrode arrays. Biosens. Bioelectron. 2023, 230, 115242. [Google Scholar] [CrossRef]
  39. Winters, H.; Coburn, J. The etching of silicon with XeF2 vapor. Appl. Phys. Lett. 1979, 34, 70–73. [Google Scholar] [CrossRef]
  40. Arana, L.R.; de Mas, N.; Schmidt, R.; Franz, A.J.; Schmidt, M.A.; Jensen, K.F. Isotropic etching of silicon in fluorine gas for MEMS micromachining. J. Micromech. Microeng. 2007, 17, 384. [Google Scholar] [CrossRef]
  41. Morbioli, G.G.; Speller, N.C.; Stockton, A.M. A practical guide to rapid-prototyping of PDMS-based microfluidic devices: A tutorial. Anal. Chim. Acta 2020, 1135, 150–174. [Google Scholar] [CrossRef]
  42. Miranda, I.; Souza, A.; Sousa, P.; Ribeiro, J.; Castanheira, E.M.; Lima, R.; Minas, G. Properties and applications of PDMS for biomedical engineering: A review. J. Funct. Biomater. 2021, 13, 2. [Google Scholar] [CrossRef] [PubMed]
  43. Vudayagiri, S.; Junker, M.D.; Skov, A.L. Factors affecting the surface and release properties of thin polydimethylsiloxane films. Polym. J. 2013, 45, 871–878. [Google Scholar] [CrossRef]
  44. Wolf, M.P.; Salieb-Beugelaar, G.B.; Hunziker, P. PDMS with designer functionalities—Properties, modifications strategies, and applications. Prog. Polym. Sci. 2018, 83, 97–134. [Google Scholar] [CrossRef]
  45. Liu, J.; Yao, Y.; Li, X.; Zhang, Z. Fabrication of advanced polydimethylsiloxane-based functional materials: Bulk modifications and surface functionalizations. Chem. Eng. J. 2021, 408, 127262. [Google Scholar] [CrossRef]
  46. Ariati, R.; Sales, F.; Souza, A.; Lima, R.A.; Ribeiro, J. Polydimethylsiloxane composites characterization and its applications: A review. Polymers 2021, 13, 4258. [Google Scholar] [CrossRef]
  47. HajjHassan, M.; Chodavarapu, V.; Musallam, S. NeuroMEMS: Neural probe microtechnologies. Sensors 2008, 8, 6704–6726. [Google Scholar] [CrossRef]
  48. Wise, K.D.; Anderson, D.J.; Hetke, J.F.; Kipke, D.R.; Najafi, K. Wireless implantable microsystems: High-density electronic interfaces to the nervous system. Proc. IEEE 2004, 92, 76–97. [Google Scholar] [CrossRef]
  49. Shen, K.; Maharbiz, M.M. Ceramic packaging in neural implants. J. Neural Eng. 2021, 18, 025002. [Google Scholar] [CrossRef]
  50. Zerr, A.; Kempf, M.; Schwarz, M.; Kroke, E.; Göken, M.; Riedel, R. Elastic moduli and hardness of cubic silicon nitride. J. Am. Ceram. Soc. 2002, 85, 86–90. [Google Scholar] [CrossRef]
  51. Kim, K.H.; Kim, K.S.; Ji, Y.J.; Kang, J.E.; Yeom, J.E. Silicon nitride deposited by laser assisted plasma enhanced chemical vapor deposition for next generation organic electronic devices. Appl. Surf. Sci. 2021, 541, 148313. [Google Scholar] [CrossRef]
  52. Xu, T.; Yoo, J.H.; Babu, S.; Roy, S.; Lee, J.-B.; Lu, H. Characterization of the mechanical behavior of SU-8 at microscale by viscoelastic analysis. J. Micromech. Microeng. 2016, 26, 105001. [Google Scholar] [CrossRef]
  53. Lee, C.; Seo, J.; Shul, Y.; Han, H. Optical properties of polyimide thin films. Effect of chemical structure and morphology. Polym. J. 2003, 35, 578–585. [Google Scholar] [CrossRef]
  54. Liu, D.; Zhou, W.; Ma, Z. Semiconductor nanomembrane-based light-emitting and photodetecting devices. Photonics 2016, 3, 40. [Google Scholar] [CrossRef]
  55. Viventi, J.; Kim, D.-H.; Vigeland, L.; Frechette, E.S.; Blanco, J.A.; Kim, Y.-S.; Avrin, A.E.; Tiruvadi, V.R.; Hwang, S.-W.; Vanleer, A.C.; et al. Flexible, foldable, actively multiplexed, high-density electrode array for mapping brain activity in vivo. Nat. Neurosci. 2011, 14, 1599–1605. [Google Scholar] [CrossRef] [PubMed]
  56. Escabí, M.A.; Read, H.L.; Viventi, J.; Kim, D.-H.; Higgins, N.C.; Storace, D.A.; Liu, A.S.; Gifford, A.M.; Burke, J.F.; Campisi, M.; et al. A high-density, high-channel count, multiplexed μECoG array for auditory-cortex recordings. J. Neurophysiol. 2014, 112, 1566–1583. [Google Scholar] [CrossRef] [PubMed]
  57. Sim, K.; Rao, Z.; Li, Y.; Yang, D.; Yu, C. Curvy surface conformal ultra-thin transfer printed Si optoelectronic penetrating microprobe arrays. NPJ Flex. Electron. 2018, 2, 2. [Google Scholar] [CrossRef]
  58. Xu, D.; Xiong, B.; Wu, G.; Wang, Y.; Sun, X.; Wang, Y. Isotropic silicon etching with $\hbox {XeF} _ {2} $ gas for wafer-level micromachining applications. J. Microelectromechanical Syst. 2012, 21, 1436–1444. [Google Scholar] [CrossRef]
  59. Rondé, M.; Walton, A.J.; Terry, J.G. Manipulating Etch Selectivities in XeF₂ Vapour Etching. J. Microelectromechanical Syst. 2020, 30, 156–164. [Google Scholar]
  60. Dos Santos, G. Xenon Difluoride Etching of Amorphous Silicon for Release of Piezoelectric Micromachined Ultrasonic Tansducer Structures. Master’s Thesis, Aalto University, Espoo, Finland, 2020. [Google Scholar]
  61. Chang, B. Technology Development of 3D Silicon Plasma Etching Processes for Novel Devices and Applications. Ph.D. Thesis, Technical University of Denmark, Kongens Lyngby, Denmark, 2018. [Google Scholar]
  62. Dunham, K.E.; Venton, B.J. Improving serotonin fast-scan cyclic voltammetry detection: New waveforms to reduce electrode fouling. Analyst 2020, 145, 7437–7446. [Google Scholar] [CrossRef]
  63. Saylor, R.A.; Hersey, M.; West, A.; Buchanan, A.M.; Berger, S.N.; Nijhout, H.F.; Reed, M.C.; Best, J.; Hashemi, P. In vivo hippocampal serotonin dynamics in male and female mice: Determining effects of acute escitalopram using fast scan cyclic voltammetry. Front. Neurosci. 2019, 13, 362. [Google Scholar] [CrossRef]
  64. Abdalla, A.; West, A.; Jin, Y.; Saylor, R.A.; Qiang, B.; Peña, E.; Linden, D.J.; Nijhout, H.F.; Reed MCBest, J.; Hashemi, P. Fast serotonin voltammetry as a versatile tool for mapping dynamic tissue architecture: I. Responses at carbon fibers describe local tissue physiology. J. Neurochem. 2020, 153, 33–50. [Google Scholar] [CrossRef]
Figure 1. Schematic for double pattern-transfer microfabrication of all GC MEAs: (1.) SU-8 3010 spin-coating and patterning of electrodes on SiO2 wafer; (2.) pyrolysis; (3.) SU-8 insulation layer spin-coating on top of the GC electrodes and UV exposure to pattern the insulation layer; (4.) deposition of the temporary transfer substrate (Polydimethylsiloxane PDMS); (5.) wet chemical-buffered oxide etching of SiO2 to release PDMS from Si substrate, transferring the MEAs on PDMS; (6.) binding of the released PDMS transfer layer with the GC traces and interconnections of the MEAs facing up to a Si wafer (temporary rigid support); (7.) SU-8 top insulation layer spin-coating and patterning of the probe outline; and finally, (8.) the insulated MEAs were gently pilled off from the PDMS.
Figure 1. Schematic for double pattern-transfer microfabrication of all GC MEAs: (1.) SU-8 3010 spin-coating and patterning of electrodes on SiO2 wafer; (2.) pyrolysis; (3.) SU-8 insulation layer spin-coating on top of the GC electrodes and UV exposure to pattern the insulation layer; (4.) deposition of the temporary transfer substrate (Polydimethylsiloxane PDMS); (5.) wet chemical-buffered oxide etching of SiO2 to release PDMS from Si substrate, transferring the MEAs on PDMS; (6.) binding of the released PDMS transfer layer with the GC traces and interconnections of the MEAs facing up to a Si wafer (temporary rigid support); (7.) SU-8 top insulation layer spin-coating and patterning of the probe outline; and finally, (8.) the insulated MEAs were gently pilled off from the PDMS.
Micromachines 15 00277 g001
Figure 2. Schematic for double dry-etching microfabrication of all GC MEAs: (1.) SU-8 3010 spin-coating and patterning of electrodes on SiO2 wafer; (2.) pyrolysis; (3.) SU-8 insulation layer spin-coating on top of the GC electrodes and UV exposure to pattern the insulation layer; (4.) spin-coating and photolithographic patterning of positive photoresist S1813 (protective sacrificial layer); (5.) CF4 reactive ion etching (RIE) of the not protected Si3N4; (6.) pure chemical isotropic XeF2 etching of the exposed Si substrate to release the devices; and (7.) after the insulated MEAs were released, the sacrificial protective layer was easily removed with acetone.
Figure 2. Schematic for double dry-etching microfabrication of all GC MEAs: (1.) SU-8 3010 spin-coating and patterning of electrodes on SiO2 wafer; (2.) pyrolysis; (3.) SU-8 insulation layer spin-coating on top of the GC electrodes and UV exposure to pattern the insulation layer; (4.) spin-coating and photolithographic patterning of positive photoresist S1813 (protective sacrificial layer); (5.) CF4 reactive ion etching (RIE) of the not protected Si3N4; (6.) pure chemical isotropic XeF2 etching of the exposed Si substrate to release the devices; and (7.) after the insulated MEAs were released, the sacrificial protective layer was easily removed with acetone.
Micromachines 15 00277 g002
Figure 3. Glassy carbon (GC) features on silicon substrate: (ac) traces and interconnects, (d) microelectrodes, (e) connection pads, and (f) aligner marks.
Figure 3. Glassy carbon (GC) features on silicon substrate: (ac) traces and interconnects, (d) microelectrodes, (e) connection pads, and (f) aligner marks.
Micromachines 15 00277 g003
Figure 4. Double pattern transfer fabrication: (a) standalone PDMS layer (300 µm thick) containing the transferred all GC-MEAs, after being released from the SiO2 wafer using a chemical buffered oxide etching, (b) zoom on the aligner marks on the standalone PDMS (GC first layer and SU-8 second layer), (c) PDMS layer transfer-bonded to a rigid silicon substrate to offer temporary support, (d,e) magnification of the microelectrodes and connecting pads post-insulation, (f) final insulated all GC-MEA (140 µm wide and ~8 µm thick, oval GC electrodes) during the peeling off from the PDMS (zoom of the folding in inset), and (g) finally insulated all GC-MEA connected to the custom-made printed circuit board (PCB) using a zero-insertion force (ZIF) connector to be interfaced with the potentiostat for characterization and sensing. The corresponding magnification of the shank in the inset (120 µm wide and ~8 µm thick, 30 µm diameter circular GC electrodes).
Figure 4. Double pattern transfer fabrication: (a) standalone PDMS layer (300 µm thick) containing the transferred all GC-MEAs, after being released from the SiO2 wafer using a chemical buffered oxide etching, (b) zoom on the aligner marks on the standalone PDMS (GC first layer and SU-8 second layer), (c) PDMS layer transfer-bonded to a rigid silicon substrate to offer temporary support, (d,e) magnification of the microelectrodes and connecting pads post-insulation, (f) final insulated all GC-MEA (140 µm wide and ~8 µm thick, oval GC electrodes) during the peeling off from the PDMS (zoom of the folding in inset), and (g) finally insulated all GC-MEA connected to the custom-made printed circuit board (PCB) using a zero-insertion force (ZIF) connector to be interfaced with the potentiostat for characterization and sensing. The corresponding magnification of the shank in the inset (120 µm wide and ~8 µm thick, 30 µm diameter circular GC electrodes).
Micromachines 15 00277 g004
Figure 5. Double dry-etching microfabrication. SEM images and elemental analysis of the surface of all GC-MEA release using isotropic XeF2 etching (side insulated with Si3N4): (a,f) composition of carbon, silicon, nitrogen, and oxygen; (b,g) silicon in red; (c,h) nitrogen in blue; and (d,i) carbon in green. (e,l) Optical picture of the final insulated all GC-MEA: magnification of different areas along the shank (120 µm wide and ~6 µm thick, oval GC electrodes).
Figure 5. Double dry-etching microfabrication. SEM images and elemental analysis of the surface of all GC-MEA release using isotropic XeF2 etching (side insulated with Si3N4): (a,f) composition of carbon, silicon, nitrogen, and oxygen; (b,g) silicon in red; (c,h) nitrogen in blue; and (d,i) carbon in green. (e,l) Optical picture of the final insulated all GC-MEA: magnification of different areas along the shank (120 µm wide and ~6 µm thick, oval GC electrodes).
Micromachines 15 00277 g005
Figure 6. Electrochemical and FSCV characterization. (a) Electrochemical impedance spectra of the magnitude impedance of GC microelectrodes (mean and SD, n = 6, (4 for pattern transfer and 2 for double etching methods). In inset: representative example of a CV plot of a GC electrode; (b) in vitro FSCV calibration conducted at GC microelectrodes in 1× PBS in the 5-HT concentration range of 0.1–1.5 μM (peak current vs. 5-HT concentration, mean and SD, n = 5, (three for pattern transfer and two for double etching methods); (c) representative background subtracted FSCVs corresponding to the considered concentration range, demonstrating clear oxidation peaks at 0.9 V and reduction peaks at 0.15 V vs Ag/AgCl; (d) representative color plot corresponding to the detection of 100 nM bolus injection of 5-HT, (e) representative color plot corresponding to the detection of 1.5 μM bolus injection, and (f) multiple consecutive repetitions (every 45 s) of 1.5 μM 5-HT bolus injections over a 5-min FSCV collection.
Figure 6. Electrochemical and FSCV characterization. (a) Electrochemical impedance spectra of the magnitude impedance of GC microelectrodes (mean and SD, n = 6, (4 for pattern transfer and 2 for double etching methods). In inset: representative example of a CV plot of a GC electrode; (b) in vitro FSCV calibration conducted at GC microelectrodes in 1× PBS in the 5-HT concentration range of 0.1–1.5 μM (peak current vs. 5-HT concentration, mean and SD, n = 5, (three for pattern transfer and two for double etching methods); (c) representative background subtracted FSCVs corresponding to the considered concentration range, demonstrating clear oxidation peaks at 0.9 V and reduction peaks at 0.15 V vs Ag/AgCl; (d) representative color plot corresponding to the detection of 100 nM bolus injection of 5-HT, (e) representative color plot corresponding to the detection of 1.5 μM bolus injection, and (f) multiple consecutive repetitions (every 45 s) of 1.5 μM 5-HT bolus injections over a 5-min FSCV collection.
Micromachines 15 00277 g006
Table 1. EDS analysis with a relative percentage of chemical elements.
Table 1. EDS analysis with a relative percentage of chemical elements.
ElementMass Normalized (%)Abs Error (%)Rel. Error (%)
Carbon56.336 ± 3.9278.222 ± 0.99811.636 ± 0.216
Nitrogen15.344 ± 3.9743.108 ± 0.82616.288 ± 2.126
Oxygen11.340 ± 3.7491.992 ± 0.35614.546 ± 0.801
Silicon16.400± 4.2020.929 ± 0.3244.382 ± 0.120
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Faul, E.-B.A.; Broussard, A.M.; Rivera, D.R.; Pwint, M.Y.; Wu, B.; Cao, Q.; Bailey, D.; Cui, X.T.; Castagnola, E. Batch Fabrication of Microelectrode Arrays with Glassy Carbon Microelectrodes and Interconnections for Neurochemical Sensing: Promises and Challenges. Micromachines 2024, 15, 277. https://doi.org/10.3390/mi15020277

AMA Style

Faul E-BA, Broussard AM, Rivera DR, Pwint MY, Wu B, Cao Q, Bailey D, Cui XT, Castagnola E. Batch Fabrication of Microelectrode Arrays with Glassy Carbon Microelectrodes and Interconnections for Neurochemical Sensing: Promises and Challenges. Micromachines. 2024; 15(2):277. https://doi.org/10.3390/mi15020277

Chicago/Turabian Style

Faul, Emma-Bernadette A., Austin M. Broussard, Daniel R. Rivera, May Yoon Pwint, Bingchen Wu, Qun Cao, Davis Bailey, X. Tracy Cui, and Elisa Castagnola. 2024. "Batch Fabrication of Microelectrode Arrays with Glassy Carbon Microelectrodes and Interconnections for Neurochemical Sensing: Promises and Challenges" Micromachines 15, no. 2: 277. https://doi.org/10.3390/mi15020277

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop