Skip to main content

REVIEW article

Front. Nephrol., 11 April 2023
Sec. Blood Purification
This article is part of the Research Topic Reviews in Frontiers in Nephrology View all 15 articles

Optimizing peritoneal dialysis catheter placement

  • Division of Nephrology, University of Virginia Health System, Charlottesville, VA, United States

Long-term success of peritoneal dialysis as a kidney replacement therapy requires a well-functioning peritoneal dialysis catheter. With ongoing reductions in infectious complications, there is an increased emphasis on the impact of catheter-related and mechanical complications. There is currently a marked variation in the utilization of various types of catheters (double cuff vs single cuff, coiled tip vs straight tip), methods of catheter insertion (advanced laparoscopic, open surgical dissection, image guided percutaneous, blind percutaneous), timing of catheter insertion, location of catheter placement (pre-sternal v. abdominal) and peri-operative practices. Specialized approaches to catheter placement in clinical practice include use of extended catheters and embedded catheters. Marked variations in patient lifestyle preferences and comorbidities, specifically in high acuity patient populations (polycystic kidney disease, obesity, cirrhosis) necessitate individualized approaches to catheter placement and care. Current consensus guidelines recommend local procedural expertise, consideration of patient characteristics and appropriate resources to support catheter placement and long-term functioning. This review focuses on an overview of approaches to catheter placement with emphasis on a patient-centered approach.

Introduction: current placement of PD catheters and issues

It is reported that approximately 424,000 patients worldwide utilize peritoneal dialysis (PD) as a method of kidney replacement therapy (1). A well- functioning PD access is essential to PD technique success, empowering patients to perform a therapy associated with reduced cost and increased patient autonomy (2, 3). There is currently marked heterogeneity in the types of PD catheter used, insertion techniques, location of placement, timing of catheter insertion and peri-operative practices. Commonly reported complications include catheter flow restriction, exit site leaks, pain and infections with resulting termination of PD, delays or interruptions in treatment, emergency department visits or hospitalizations, and need for corrective procedures. Studies have reported 13-17% of PD technique failure are due to mechanical catheter complications (46). Additionally, there is variability in the definitions, reporting methods, choice of outcomes, and analysis of PD access outcomes which hampers the determination of best practices for PD catheter placement (7).

What is optimal PD catheter placement: patient-centered approach

Knowledge of best practices in catheter insertion can minimize the risk of catheter complications leading to early PD failure. Guideline committees under the sponsorship of the International Society for Peritoneal Dialysis (ISPD) recommend optimal PD catheter implantation be based on individualized patient factors, facility resources and operator expertise (8). Currently, most PD catheters for chronic use are made of silicone rubber. There is a marked variability in the types of PD catheters available for use, and include the most common type of double cuff, straight or coiled-tip Tenckhoff catheters with a pre-formed arc bend in the intercuff segment. While single cuff catheters are available, double cuff catheter are thought to be superior in preventing peritonitis caused by periluminal entry of organisms (especially given variable compliance with prophylactic antibiotic ointment used to lessen the risk of exit site infections), and for firm tissue fixation of the catheter (9). There is no significant difference in functionality between straight- and coiled-tip catheters, with or without preformed arc bend (1012). While coiled-tip catheters are theorized to have less incidence of inflow discomfort and better dialysate dispersion, these effects have not been studied specifically, hence catheter selection is determined largely by availability of local inventory.

Recent PD catheter registries have reported a marked variation in PD catheter insertion techniques that include open surgical dissection, laparoscopic insertion with advanced techniques, blind insertion via trocar and blind insertion via Seldinger technique (13, 14). An optimal patient centered approach balances local procedural expertise along with patient specific factors and local resource availability. A laparoscopic approach is utilized in patients generally considered safe for general anesthesia with a history of prior abdominal surgeries in addition to having flexibility of waiting for an operating room time (8). Moreover, the laparoscopic approach allows the performance of advanced surgical techniques including rectus sheath tunneling (which reduces risk of pericatheter leaks and prevents tip migration), prophylactic omentopexy and adhesiolysis (which can improve inflow and outflow of dialysate fluid). The ability to perform these proactive adjunctive techniques are thought to improve catheter outcomes (1517). A recent metanalysis observed a significant reduction in flow obstruction and tip migration when advanced laparoscopic techniques were utilized (18). Additionally, the laparoscopic approach allows for concomitant repair of abdominal wall hernias. Percutaneous catheter insertions by radiologists or nephrologists have been utilized in patients needing PD access in an accelerated timeline (more timely than awaiting operating room time), no major prior abdominal surgeries, and it precludes the need for general anesthesia. However, the percutaneous technique obviates the ability to visualize adhesions, and perform advanced adjunctive techniques. An open surgical dissection method (under local or general anesthesia) has also been utilized for timely placement of PD catheters, both by nephrologists as well as surgeons. Similar to the percutaneous technique, advanced adjunctive techniques cannot be performed via open surgical technique (9, 19, 20).

Another tailored approach to optimizing outcomes is consideration of the timing of PD catheter insertion. There is a marked variation in estimated glomerular filtration rates (5- 8 ml/min) at the time of catheter placement (21, 22). Early planning and placement offers larger flexibility to resolve early insertion related problems. A well- organized urgent start PD initiation program with rapid access to catheter insertion allows for new dialysis patients to initiate and establish on PD rather than hemodialysis. However, a caution is that PD catheter use within 7 days of insertion has been showed to increase the risk of exit site leaks and infections, compared to standard initiation (28 days) (23). Specific catheter insertion related interventions to mitigate early complications include utilization of fibrin glue, and additional purse-string sutures at the level of deep cuff as well as near peritoneal membrane (24, 25).

Another strategy for timely initiation of PD is the embedded catheter technique, with the external limb of catheter embedded in subcutaneous tissue until the need for dialysis initiation. This allows for early patient commitment to PD, more predictable operating room scheduling, and immediate utilization of the catheter after exteriorization. However, there is a risk of non-usage of catheters, in addition to catheter dysfunction rates secondary to fibrin accumulation (2628).

No specific catheter placement approach has been proven to produce superior outcomes. Comparison of percutaneous placement, open surgical dissection and basic surgical laparoscopy have shown equivalent patient outcomes (21, 2931). However, studies investigating outcomes in advanced laparoscopic studies demonstrate superior outcomes compared to other approaches (18). Patient factors aside, optimal PD catheter placement involves operator expertise, and the ability to provide peritoneal access in a timely fashion. While seemingly simple, PD catheter placement is a critical life-sustaining procedure and patients benefit from experienced operators who are able to identify and rectify problems with catheter placement in a timely manner. When access to an operating room is rate-limiting, percutaneous insertion by a nephrologist for an appropriate patient is a reasonable option, and also provides ongoing continuity of care, patient satisfaction and high rates of peritoneal dialysis utilization (32).

Approaches to PD catheter placement

The goals of PD catheter placement involve a balance between pelvic position of catheter tip to facilitate inflow and outflow of dialysate along with an easily visible and accessible exit site. Operator expertise and experience necessitates selection of appropriate available catheter type suited to patient specific conditions. Placement includes the consideration of body habitus, belt-line, skin creases, prior scars, stomas, gastrostomy tubes, recreational habits and occupation. An ideal exit site is either above or below the beltline, with a lateral and inferior directed exit site (Figures 1A, B). However, based upon patient-specific criteria, other positions for the catheter exit site may be more appropriate. The catheter insertion site and length of intraperitoneal tubing determines the pelvic position of the catheter tip. While a catheter tip in the pelvis is preferred for optimal hydraulic function, excessively deep placement, or a catheter tip between the rectum and bladder can result in extrinsic catheter compression, flow impairment and pain with draining of the dialysate (33). In the pre-operative planning, the patient is examined while both supine and sitting, using the pubic symphysis as a guide to catheter tip location. Examination in the sitting position allows for visualization of an appropriate exit site (34).

FIGURE 1
www.frontiersin.org

Figure 1 Illustrations of PD catheter positions with regards to exit site position (A) Laterally directed exit site emerging above the beltline. (B) Downward directed exit site below a high beltline. (C) Extended catheter system with an upper abdominal exit site. (D) Extended catheter system with a presternal exit site (9).

Several patient factors necessitate utilization of an extended-length catheter system. Patients with excessive skin folds, stomas, incontinence, necessity for bath tub or other factors would benefit from an upper abdominal or pre-sternal exit site (Figures 1C, D). This can be achieved via a 2- piece extended catheter system, with a long subcutaneous section, while maintaining optimal catheter tip position. Alternatively, single piece catheters with long intercuff segments are also utilized in certain centers (35, 36).

Regardless of a standard vs extended approach, best practices in patient preparation catheter placement have been detailed in multiple publications and include appropriate selection of catheter type and exit site location, pre-op bowel preparation, utilization of a paramedian incision, deep cuff placement within or below the rectus muscle, lateral and downward directed exit site (8).

Catheter placement in special populations

Several high acuity patient conditions (obesity, polycystic kidney disease, cirrhosis/ascites) necessitate a specialized approach for successfully conducting PD as a dialysis modality. This includes not only optimal exit site and catheter tip position, but utilization of focused interventions to ensure ideal long term function. Patients with obesity require creation of an easily visible upper abdomen/presternal exit site requiring an extended catheter approach. The catheter should be allowed to heal completely for several weeks prior to PD initiation. Ideally, a laparoscopic approach is recommended, utilizing selective omentopexy along with resection of epiploic appendices of sigmoid colon if needed. The upper abdominal and chest exit sites are located in areas with relatively thin subcutaneous layer, minimizing tubing stresses from mobility of the subcutaneous fat layer with postural changes. Data suggests longer time to first exit site infections in patients with extended catheters (37). Moreover, extended catheters enable peritoneal access in a subgroup of patients in whom conventional catheter placement would not be possible.

Patients with autosomal dominant polycystic kidney disease (ADPKD) present a unique set of concerns regarding limited peritoneal space, peritonitis risk and hernias. Several studies have reported the feasibility of PD in ADPKD patients (3840). With regards to long term mechanical complications, these patients are at increased risk of abdominal wall hernias. The cause of these hernias is possibly multifactorial given increased intraperitoneal pressure in addition to possible collagen defects (41, 42). Simultaneous hernia repair and catheter insertion can safely be performed, and a tension- free hernia repair with prosthetic mesh is essential to minimize the risk of recurrence (43, 44).To prevent visceral injury to enlarged abdominal organs, laparoscopic ports, trocars and needles must be inserted and manipulated with increased caution. Ultrasound-guided percutaneous insertion of trocars is a feasible option for prevention of iatrogenic injury (45).

Patients with cirrhosis present their own unique challenges with regards to potential bacterial peritonitis, nutritional challenges, and concerns for leaks (4649). Several centers have published their experiences regarding perioperative management of ascites. One center has reported catheter placement followed by 5-6 liters of large volume paracentesis. Thereafter, peritoneal drainage volume is allowed to exceed infused volume by 200 ml, allowing for a gradual and controlled drainage (47).Other centers have reported initiating low volume PD exchanges immediately following catheter placement. The drain volumes have been permitted to exceed infused volumes by 20% in certain reports, whereas others have reported an increase in 400-600 ml of effluent over the first few days. This allows for a safe and slow pattern of decompression, allowing for gradual ascites removal prior to training commencement (4749).

Conclusion

Safe and effective placement of PD access is critical to the ultimate outcomes of PD as a home dialysis modality. Table 1 provides a guideline of potential PD catheter placement measures that home programs should consider monitoring to ensure continuous quality improvement. Ultimately, an effective PD catheter can serve the patient for many years and provide a life-sustaining therapy but this relies on an experienced team that carefully assesses each patient, identifies patient-specific issues that may impede optimal outcomes and addresses these issue through careful planning and monitoring.

TABLE 1
www.frontiersin.org

Table 1 Factors to consider monitoring to ensure optimal pd catheter function and longevity.

Author contributions

SK and MR were responsible for preparation, writing and editing of this manuscript. Both authors contributed to the article and approved the submitted version.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Fresenius Medical Care Annual Report. USA (2021).

Google Scholar

2. Chui BK, Manns B, Pannu N, Dong J, Wiebe N, Jindal K, et al. Health care costs of peritoneal dialysis technique failure and dialysis modality switching. Am J Kidney Dis (2013) 61(1):104–11. doi: 10.1053/j.ajkd.2012.07.010

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Mehrotra R, Devuyst O, Davies SJ, Johnson DW. The current state of peritoneal dialysis. J Am Soc Nephrol. (2016) 27(11):3238–52. doi: 10.1681/ASN.2016010112

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Htay H, Cho Y, Pascoe EM, Darssan D, Nadeau-Fredette AC, Hawley C, et al. Multicenter registry analysis of center characteristics associated with technique failure in patients on incident peritoneal dialysis. Clin J Am Soc Nephrol. (2017) 12(7):1090–9. doi: 10.2215/CJN.12321216

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Guo A, Mujais S. Patient and technique survival on peritoneal dialysis in the united states: Evaluation in large incident cohorts. Kidney Int Suppl (2003) 88):S3–12. doi: 10.1046/j.1523-1755.2003.08801.x

CrossRef Full Text | Google Scholar

6. Mujais S, Story K. Peritoneal dialysis in the US: Evaluation of outcomes in contemporary cohorts. Kidney Int Suppl (2006) 103):S21–6. doi: 10.1038/sj.ki.5001912

CrossRef Full Text | Google Scholar

7. Elbokl M, Momciu B, Kishibe T, Oliver MJ, Perl J. Peritoneal dialysis access outcomes reported in randomized controlled trials: A systematic review. Perit Dial Int (2021) 41(6):552–63. doi: 10.1177/0896860820966898

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Crabtree JH, Shrestha BM, Chow KM, Figueiredo AE, Povlsen JV, Wilkie M, et al. Creating and maintaining optimal peritoneal dialysis access in the adult patient: 2019 update. Perit Dial Int (2019) 39(5):414–36. doi: 10.3747/pdi.2018.00232

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Crabtree JH, Chow KM. Peritoneal dialysis catheter insertion. Semin Nephrol. (2017) 37(1):17–29. doi: 10.1016/j.semnephrol.2016.10.004

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Xie J, Kiryluk K, Ren H, Zhu P, Huang X, Shen P, et al. Coiled versus straight peritoneal dialysis catheters: A randomized controlled trial and meta-analysis. Am J Kidney Dis (2011) 58(6):946–55. doi: 10.1053/j.ajkd.2011.06.026

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Ouyang CJ, Huang FX, Yang QQ, Jiang ZP, Chen W, Qiu Y, et al. Comparing the incidence of catheter-related complications with straight and coiled tenckhoff catheters in peritoneal dialysis patients-a single-center prospective randomized trial. Perit Dial Int (2015) 35(4):443–9. doi: 10.3747/pdi.2013.00016

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Johnson DW, Wong J, Wiggins KJ, Kirwan R, Griffin A, Preston J, et al. A randomized controlled trial of coiled versus straight swan-neck tenckhoff catheters in peritoneal dialysis patients. Am J Kidney Dis (2006) 48(5):812–21. doi: 10.1053/j.ajkd.2006.08.010

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Wallace EL, Fissell RB, Golper TA, Blake PG, Lewin AM, Oliver MJ, et al. Catheter insertion and perioperative practices within the ISPD north American research consortium. Perit Dial Int (2016) 36(4):382–6. doi: 10.3747/pdi.2015.00089

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Lanot A, Bechade C, Verger C, Fabre E, Vernier I, Lobbedez T. Patterns of peritoneal dialysis catheter practices and technique failure in peritoneal dialysis: A nationwide cohort study. PloS One (2019) 14(6):e0218677. doi: 10.1371/journal.pone.0218677

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Attaluri V, Lebeis C, Brethauer S, Rosenblatt S. Advanced laparoscopic techniques significantly improve function of peritoneal dialysis catheters. J Am Coll Surg (2010) 211(6):699–704. doi: 10.1016/j.jamcollsurg.2010.08.010

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Crabtree JH, Burchette RJ. Effective use of laparoscopy for long-term peritoneal dialysis access. Am J Surg (2009) 198(1):135–41. doi: 10.1016/j.amjsurg.2008.10.019

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Ogunc G. Minilaparoscopic extraperitoneal tunneling with omentopexy: a new technique for CAPD catheter placement. Perit Dial Int (2005) 25(6):551–5. doi: 10.1177/089686080502500609

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Shrestha BM, Shrestha D, Kumar A, Shrestha A, Boyes SA, Wilkie ME. Advanced laparoscopic peritoneal dialysis catheter insertion: Systematic review and meta-analysis. Perit Dial Int (2018) 38(3):163–71. doi: 10.3747/pdi.2017.00230

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Kang SH, Park JW, Cho KH, Do JY. Comparison of peritoneal dialysis catheter insertion techniques by nephrologists: Surgical vs blind methods. Semin Dial. (2021) 34(1):31–7. doi: 10.1111/sdi.12904

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Park YS, Min SI, Kim DK, Oh KH, Min SK, Kim SM, et al. The outcomes of percutaneous versus open placement of peritoneal dialysis catheters. World J Surg (2014) 38(5):1058–64. doi: 10.1007/s00268-013-2346-5

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Voss D, Hawkins S, Poole G, Marshall M. Radiological versus surgical implantation of first catheter for peritoneal dialysis: A randomized non-inferiority trial. Nephrol Dial Transplant. (2012) 27(11):4196–204. doi: 10.1093/ndt/gfs305

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Oliver MJ, Perl J, McQuillan R, Blake PG, Jain AK, McCormick B, et al. Quantifying the risk of insertion-related peritoneal dialysis catheter complications following laparoscopic placement: Results from the north American PD catheter registry. Perit Dial Int (2020) 40(2):185–92. doi: 10.1177/0896860819893813

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Ranganathan D, John GT, Yeoh E, Williams N, O'Loughlin B, Han T, et al. A randomized controlled trial to determine the appropriate time to initiate peritoneal dialysis after insertion of catheter (Timely PD study). Perit Dial Int (2017) 37(4):420–8. doi: 10.3747/pdi.2016.00066

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Hisamatsu C, Maeda K, Aida Y, Yasufuku M, Ninchoji T, Kaito H, et al. A novel technique of catheter placement with fibrin glue to prevent pericatheter leakage and to enable no break-in period in peritoneal dialysis. J Pediatr Urol. (2015) 11(5):299–300. doi: 10.1016/j.jpurol.2015.07.005

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Ye H, Yang X, Yi C, Guo Q, Li Y, Yang Q, et al. Urgent-start peritoneal dialysis for patients with end stage renal disease: A 10-year retrospective study. BMC Nephrol. (2019) 20(1):238. doi: 10.1186/s12882-019-1408-9

PubMed Abstract | CrossRef Full Text | Google Scholar

26. McCormick BB, Brown PA, Knoll G, Yelle JD, Page D, Biyani M, et al. Use of the embedded peritoneal dialysis catheter: experience and results from a north American center. Kidney Int Suppl (2006) 103):S38–43. doi: 10.1038/sj.ki.5001914

CrossRef Full Text | Google Scholar

27. Crabtree JH, Burchette RJ, Siddiqi RA. Embedded catheters: Minimizing excessive embedment time and futile placement while maintaining procedure benefits. Perit Dial Int (2015) 35(5):545–51. doi: 10.3747/pdi.2013.00301

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Sinha S, Fok M, Davenport A, Banga N, Lindsey B, Fernando B, et al. Use of the embedded peritoneal dialysis catheter. Ann R Coll Surg Engl (2018) 100(7):534–44. doi: 10.1308/rcsann.2018.0088

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Boujelbane L, Fu N, Chapla K, Melnick D, Redfield RR, Waheed S, et al. Percutaneous versus surgical insertion of PD catheters in dialysis patients: a meta-analysis. J Vasc Access. (2015) 16(6):498–505. doi: 10.5301/jva.5000439

PubMed Abstract | CrossRef Full Text | Google Scholar

30. van Laanen JHH, Cornelis T, Mees BM, Litjens EJ, van Loon MM, Tordoir JHM, et al. Randomized controlled trial comparing open versus laparoscopic placement of a peritoneal dialysis catheter and outcomes: The CAPD I trial. Perit Dial Int (2018) 38(2):104–12. doi: 10.3747/pdi.2017.00023

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Ozener C, Bihorac A, Akoglu E. Technical survival of CAPD catheters: comparison between percutaneous and conventional surgical placement techniques. Nephrol Dial Transplant. (2001) 16(9):1893–9. doi: 10.1093/ndt/16.9.1893

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Perl J, Pierratos A, Kandasamy G, McCormick BB, Quinn RR, Jain AK, et al. Peritoneal dialysis catheter implantation by nephrologists is associated with higher rates of peritoneal dialysis utilization: a population-based study. Nephrol Dial Transplant. (2015) 30(2):301–9. doi: 10.1093/ndt/gfu359

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Blake P. Drain pain, overfill, and how they are connected. Perit Dial Int (2014) 34(4):342–4. doi: 10.3747/Pdi.2014.00104

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Crabtree JH, Burchette RJ. Prospective comparison of downward and lateral peritoneal dialysis catheter tunnel-tract and exit-site directions. Perit Dial Int (2006) 26(6):677–83. doi: 10.1177/089686080602600612

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Crabtree JH. Extended peritoneal dialysis catheters for upper abdominal wall exit sites. Perit Dial Int (2004) 24(3):292–4. doi: 10.1177/089686080402400314

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Eriguchi M, Tsuruya K, Yoshida H, Haruyama N, Tanaka S, Tsuchimoto A, et al. Extended swan-neck catheter with upper abdominal exit-site reduces peritoneal dialysis-related infections. Ther Apher Dial. (2016) 20(2):158–64. doi: 10.1111/1744-9987.12358

PubMed Abstract | CrossRef Full Text | Google Scholar

37. Crabtree JH, Burchette RJ. Comparative analysis of two-piece extended peritoneal dialysis catheters with remote exit-site locations and conventional abdominal catheters. Perit Dial Int (2010) 30(1):46–55. doi: 10.3747/pdi.2009.00004

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Li L, Szeto CC, Kwan BC, Chow KM, Leung CB, Kam-Tao Li P. Peritoneal dialysis as the first-line renal replacement therapy in patients with autosomal dominant polycystic kidney disease. Am J Kidney Dis (2011) 57(6):903–7. doi: 10.1053/j.ajkd.2011.01.019

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Janeiro D, Portoles J, Tato AM, Lopez-Sanchez P, Del Peso G, Rivera M, et al. Peritoneal dialysis can be an option for dominant polycystic kidney disease: An observational study. Perit Dial Int (2015) 35(5):530–6. doi: 10.3747/pdi.2014.00029

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Lobbedez T, Touam M, Evans D, Ryckelynck JP, Knebelman B, Verger C. Peritoneal dialysis in polycystic kidney disease patients. report from the French peritoneal dialysis registry (RDPLF). Nephrol Dial Transplant. (2011) 26(7):2332–9. doi: 10.1093/ndt/gfq712

PubMed Abstract | CrossRef Full Text | Google Scholar

41. Courivaud C, Roubiou C, Delabrousse E, Bresson-Vautrin C, Chalopin JM, Ducloux D. Polycystic kidney size and outcomes on peritoneal dialysis: Comparison with haemodialysis. Clin Kidney J (2014) 7(2):138–43. doi: 10.1093/ckj/sft171

PubMed Abstract | CrossRef Full Text | Google Scholar

42. Morris-Stiff G, Coles G, Moore R, Jurewicz A, Lord R. Abdominal wall hernia in autosomal dominant polycystic kidney disease. Br J Surg (1997) 84(5):615–7.

PubMed Abstract | Google Scholar

43. Crabtree JH. Hernia repair without delay in initiating or continuing peritoneal dialysis. Perit Dial Int (2006) 26(2):178–82. doi: 10.1177/089686080602600209

PubMed Abstract | CrossRef Full Text | Google Scholar

44. Garcia-Urena MA, Rodriguez CR, Vega Ruiz V, Carnero Hernandez FJ, Fernandez-Ruiz E, Vazquez Gallego JM, et al. Prevalence and management of hernias in peritoneal dialysis patients. Perit Dial Int (2006) 26(2):198–202. doi: 10.1177/089686080602600214

PubMed Abstract | CrossRef Full Text | Google Scholar

45. Shanmugalingam R, Makris A, Hassan HC, Li Y, DeGuzman I, Nandakoban H, et al. The utility of sonographic assessment in selecting patients for percutaneous insertion of peritoneal dialysis catheter. Perit Dial Int (2017) 37(4):434–42. doi: 10.3747/pdi.2017.00006

PubMed Abstract | CrossRef Full Text | Google Scholar

46. Bajo MA, Selgas R, Jimenez C, Del Peso G, Fernandez-Reyes MJ, Dapena F, et al. CAPD for treatment of ESRD patients with ascites secondary to liver cirrhosis. Adv Perit Dial. (1994) 10:73–6.

PubMed Abstract | Google Scholar

47. Selgas R, Bajo MA, Del Peso G, Sanchez-Villanueva R, Gonzalez E, Romero S, et al. Peritoneal dialysis in the comprehensive management of end-stage renal disease patients with liver cirrhosis and ascites: practical aspects and review of the literature. Perit Dial Int (2008) 28(2):118–22. doi: 10.1177/089686080802800203

PubMed Abstract | CrossRef Full Text | Google Scholar

48. Chaudhary K, Khanna R. Renal replacement therapy in end-stage renal disease patients with chronic liver disease and ascites: role of peritoneal dialysis. Perit Dial Int (2008) 28(2):113–7. doi: 10.1177/089686080802800202

PubMed Abstract | CrossRef Full Text | Google Scholar

49. De Vecchi AF, Colucci P, Salerno F, Scalamogna A, Ponticelli C. Outcome of peritoneal dialysis in cirrhotic patients with chronic renal failure. Am J Kidney Dis (2002) 40(1):161–8. doi: 10.1053/ajkd.2002.33925

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: dialysis (ESKD), peritoneal, dialysis catheter complications, outcomes - health care, long term optimal planning

Citation: Khan SF and Rosner MH (2023) Optimizing peritoneal dialysis catheter placement. Front. Nephrol. 3:1056574. doi: 10.3389/fneph.2023.1056574

Received: 29 September 2022; Accepted: 22 March 2023;
Published: 11 April 2023.

Edited by:

Irma Tchokhonelidze, Tbilisi State Medical University, Georgia

Reviewed by:

Matthias Zeiler, “C. e G. Mazzoni” Hospital, Italy
Pankaj N. Maheshwari, Fortis Hospital, India

Copyright © 2023 Khan and Rosner. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Sana F. Khan, sk4yp@virginia.edu

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.