日本建築学会構造系論文集
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
柱RC・梁S混合構造接合邦の終局せん断耐力に関する研究
金 洸演野口 博
著者情報
ジャーナル フリー

1998 年 63 巻 507 号 p. 163-169

詳細
抄録

In this study, previous test specimens of RC column-S beam connections were analyzed by 3-D FEM to investigate the effect of connection types or reinforcing details on the ultimate shear strength of the RCS connections. From the analytical results, the effective factor of a web width is about 0.8 in case of an exterior type, and about 0.6 in case of a corner type. The effective width of outer concrete was decided by assuming that the inner concrete resists in all and the strength due to each reinforcing detail can be accumulated. The calculated results by the proposed equation gave a good agreement with the experimental results and analytical results.

著者関連情報
© 1998 日本建築学会
前の記事 次の記事
feedback