Abstract
The issues of applying a soft-start apparatus (SSA) to conveyor start ups are considered in the article. SSAs use control of the first harmonic of asynchronous motor stator voltage for this purposes. The low efficiency of the existing SSA control circuits and algorithms for this class of drives for the criterion of mechanical loading reduction in the conveyor belt during start up is demonstrated. Control circuits and algorithms that allow one to raise SSA efficiency as the a.m. criterion are proposed.
Similar content being viewed by others
References
Rassudov, L.N. and Myadzel’, V.N., Elektroprivody s raspredelennymi parametrami mekhanicheskikh elementov (Electric Drives with Distributed Parameters of Mechanical Elements), Leningrad: Energoatomoizdat, 1987.
Zyuzev, A.M., Metel’kov, V.P., and Radchenko, V.N., Mathematical Model of Round-Trip Mechanism of a Rig, Izv. Vyssh. Uchebn. Zaved., Gornyi zhurnal, 2003, no. 5, pp. 22–30.
Zyuzev, A.M., Lipanov, V.M., Metel’kov, V.P., et al., Software Package Intended for Investigation of Operating Conditions of Rigs’ Electric Drives, Elektrotekhnika, 2003, no. 7, pp. 25–31.
Zyuzev, A.M. and Nesterov, K.E., Methods of Indirect Estimation of Motors Speed in the Systems “Thyristor Voltage Converter-Induction Motor”, Elektrotekhnika, 2009, no. 9, pp. 45–49.
Additional information
Original Russian Text © A.M. Zyuzev, V.P. Metel’kov, 2009, published in Elektrotekhnika, 2009, No. 9, pp. 41–45.
About this article
Cite this article
Zyuzev, A.M., Metel’kov, V.P. Study of start-up modes of conveyor drives. Russ. Electr. Engin. 80, 498–501 (2009). https://doi.org/10.3103/S1068371209090065