Gamma Spectrometry System for Decommissioning Nuclear Facilities

  • Published:
Bulletin of the Lebedev Physics Institute Aims and scope Submit manuscript

Abstract

The structure of gamma spectrometry systems for decommissioning nuclear facilities is considered. Physicotechnical characteristics of a xenon gamma spectrometer being a main device for measuring gamma spectra of analyzed objects and determining their activity are presented. The practicability of xenon gamma spectrometers in decommissioning nuclear facilities is shown. The data obtained using the gamma spectrometry system is transmitted over internet to a remote computer to process experimental data in real time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.

Similar content being viewed by others

REFERENCES

  1. R. Guzman, R. Navarro, J. Ferre, and M. Moreno, “RESCUER: Development of a Modular Chemical, Biological, Radiological, and Nuclear Robot for Intervention, Sampling, and Situation Awareness,” J. Field Robot. 33, 931 (2016). https://doi.org/10.1002/rob.21588

    Article  Google Scholar 

  2. S. E. Ulin, K. F. Vlasik, A. M. Galper, V. M. Grachev, V. V. Dmitrenko, V. I. Liagushin, Z. M. Uteshev, and Yu. T. Yurkin, “Influence of Proton and Neutron Fluxes on Spectrometric Characteristics of a High-Pressure Xenon Gamma Spectrometer,” Proc. SPIE, 3114, 499 (2017). https://doi.org/10.1117/12.283789

    Article  Google Scholar 

  3. K. F. Vlasik, V. M. Grachev, V. V. Dmitrenko, S. E. Ulin, Z. M. Uteshev, and Yu. T. Yurkin, Effect of Proton and Neutron Fluxes on the Spectrometric Characteristics of the High-Pressure Xenon γ-Ray Spectrometer,” Instrum. Exp. Tech. 41, 309 (1998).

    Google Scholar 

  4. A. S. Novikov, S. E. Ulin, I. V. Chernysheva, V. V. Dmitrenko, V. M. Grachev, D. V. Petrenko, A. E. Shustov, Z. M. Uteshev, and K. F. Vlasik, “Xenon Detector with High Energy Resolution for Gamma-Ray Line Emission Registration,” Proc. SPIE 9213, 921318 (2014). https://doi.org/10.1117/12.2060812

    Article  Google Scholar 

Download references

Funding

This study was supported by the Ministry of Science and Higher Education of the Russian Federation (the unique project identifier is RFMEFI61419X0003).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. E. Ulin.

Additional information

Translated by A. Kazantsev

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ulin, S.E., Dmitrenko, V.V., Vlasik, K.F. et al. Gamma Spectrometry System for Decommissioning Nuclear Facilities. Bull. Lebedev Phys. Inst. 47, 176–180 (2020). https://doi.org/10.3103/S1068335620060081

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S1068335620060081

Keywords:

Navigation