Comparison of the use of new handheld tonometers and established applanation tonometers in dogs

Christiane Görig , DVM, Dr med vet Roel T. I. Coenen , DVM Frans C. Stades , DVM, PhD Sylvia C. Djajadiningrat-Laanen , DVM Michael H. Boevé , DVM, PhD
Department of Clinical Sciences of Companion Animals, Faculty of Veterinary Medicine, University of Utrecht, Yalelaan 8, 3508 TD Utrecht, The Netherlands. (Görig, Stades, Djajadiningrat-Laanen, Boevé); Animal Clinic Groenlo-Lichtenvoorde, Zieuwentseweg 4a, 7131 LB Lichtenvoorde, the Netherlands. (Coenen)
Address correspondence to Dr. Görig.

Supported by Reichert Ophthalmic Instruments and Tiolat.

Presented in part at the Annual Meeting of the European College of Veterinary Ophthalmologists, München, Germany, June 2004.

The authors thank X. Lescure and H. de Groot for assistance with the study.

Objective—To examine the practical aspects, accuracy, and reproducibility of 2 new automatic handheld tonometers in dogs and compare them with results for 2 established applanation tonometers.

Animals—15 freshly enucleated canine eyes for manometric evaluation and 20 conscious research dogs, 20 client-owned dogs, and 12 dogs with acute glaucoma for clinical tonometry.

Procedure—Calibration curves were determined for all 4 tonometers on 15 enucleated canine eyes. Intraocular pressure (IOP) was measured with each tonometer consecutively in conscious dogs, with the MacKay-Marg applanation tonometer as the reference device. Measurements were repeated in 20 sedated dogs. An induction-impact tonometer was evaluated clinically on dogs with acute glaucoma. Additionally, measurements obtained by an experienced and an inexperienced examiner and with or without use of topical anesthesia were compared.

Results—The portable pneumatonometer was cumbersome and time-consuming. Compared with results for the reference applanation tonometer, and confirmed by manometry, the portable pneumatonometer increasingly underestimated actual IOP values with increasing IOP. The induction-impact tonometer provided accurate and reproducible measurement values. There was a significant strong correlation between the IOP values obtained by the 2 examiners (r2, 0.82) and also with or without topical anesthesia (r2, 0.86). In dogs with glaucoma, the fitted line comparing values for the reference applanation tonometer and induction-impact tonometer closely resembled an ideal 1:1 relationship.

Conclusions and Clinical Relevance—Use of the portable pneumatonometer in dogs appears to have disadvantages. The induction-impact tonometer appears to provide a promising alternative to the use of applanation tonometers in dogs.



CITING ARTICLES
, , , . (2008) Effect of body position on intraocular pressure in dogs without glaucoma. American Journal of Veterinary Research 69:4, 527-530
Online publication date: 1-Apr-2008.
Abstract | PDF (273 KB) | PDF Plus (286 KB) 

PDF (676.148 KB) PDF Plus (235.658 KB)
 

Prev. Article | Next Article
View/Print PDF (676 KB)
View PDF Plus (236 KB)
Add to favorites
Email to a friend
TOC Alert | Citation Alert What is RSS?

Quick Links
 • Alert me when new articles cite this article
 • Download to citation manager
 • Related articles found in:
AVMA
 • View Most Downloaded Articles
 
 
Quick Search
for 
Authors:
Christiane Görig
Roel T. I. Coenen
Frans C. Stades
Sylvia C. Djajadiningrat-Laanen
Michael H. Boevé
American Veterinary Medical Association, 1931 North Meacham Road - Suite 100, Schaumburg, IL 60173
Phone: 847-925-8070, Fax: 847-925-1329, E-mail: avmajournals@avma.org

Technology Partner - Atypon Systems, Inc.