Sign inSign up

ADSA Society

Logo
IssuesFor AuthorsAdvertisingNewsHelp

ADSA Society

Article Contents

  • METHODS
  • RESULTS
  • DISCUSSION
  • REFERENCES
Save
Download PDF

The purpose of this study was to compare the effectiveness of various concentrations of N2O/O2 on obtunding a hypersensitive gag reflex. We hypothesized that the administration of nitrous oxide and oxygen would obtund a hypersensitive gag reflex enough to allow a patient to tolerate the placement and holding of a digital x-ray sensor long enough to obtain a dental radiograph. Volunteers claiming to have a hypersensitive gag reflex were first screened to validate their claim and then tested by placing a size 2 digital x-ray sensor in the position for a periapical radiograph of the right mandibular molar area and holding it in place for 10 seconds. Subjects were first tested using room air only, then 30%, 50%, or 70% nitrous oxide until they were able to tolerate the sensor without gagging or discomfort. A visual analog scale was used for subjective responses, and other statistical tests were used to analyze the results. We found that for some subjects, 30% nitrous oxide was sufficient; for others, 50% was needed; and for the remainder of the subjects, 70% was sufficient to tolerate the test. Using a combination of 70% nitrous oxide and 30% oxygen allowed all patients claiming to have a hypersensitive gag reflex to tolerate the placement and holding of a digital x-ray sensor long enough to take a periapical radiograph.

Keywords: Gag reflex; Hypersensitive gag reflex; Dental radiographs; Nitrous oxide and oxygen
  • Download PDF
Copyright: © 2016 by the American Dental Society of Anesthesiology
Citations

The ASDA-AAOMS-AAP Rules Template

Kyle J. Kramer DDS, MS

Comparison of Remimazolam and Propofol for Intubated General Anesthesia for Oral and Maxillofacial Surgery

Yoshio Hayakawa DDS, PhD,
 Keiko Fujii-Abe DDS, PhD,
 Sayaka Akitomi DDS,
 Shihomi Niwa DDS,
 Michiru Abe DDS,
 Manami Otsuka DDS, PhD,
 Maho Ikeda DDS,
 Takumi Ishikawa DDS, PhD,
 Manami Yajima DDS, PhD, and
 Hiroshi Kawahara DDS, PhD

The Impact of COVID-19 on Dental Anesthesiologists: An Online Survey of Board-Certified Dental Anesthesiology Specialists of the Japanese Dental Society of Anesthesiology

Takuro Sanuki DDS, PhD,
 Hidetaka Kuroda DDS, PhD,
 Uno Imaizumi DDS, PhD,
 Shota Tsukimoto DDS, PhD,
 Norika Katagiri DDS, PhD,
 Ayako Mizutani DDS, PhD,
 Mari Ohnaka DDS,
 Shinji Kurata DDS, PhD,
 Naotaka Kishimoto DDS, PhD, and
 Kanta Kido DDS, PhD

Tracheal Bronchus Detected During General Anesthesia: A Case Report

Toru Yamamoto DDS, PhD,
 Tatsuru Tsurumaki DDS, PhD,
 Hiroko Kanemaru DDS, PhD, and
 Kenji Seo DDS, PhD

Management of an Ingested Foreign Body in a COVID-Positive Patient

Tiffany Smith BS,
 Rachel Blum BS, and
 Raquel Rozdolski DMD

Get Email Alerts

Article Contents

Comparison of Remimazolam and Propofol for Intubated General Anesthesia for Oral and Maxillofacial Surgery

Yoshio Hayakawa DDS, PhD,
 Keiko Fujii-Abe DDS, PhD,
 Sayaka Akitomi DDS,
 Shihomi Niwa DDS,
 Michiru Abe DDS,
 Manami Otsuka DDS, PhD,
 Maho Ikeda DDS,
 Takumi Ishikawa DDS, PhD,
 Manami Yajima DDS, PhD, and
 Hiroshi Kawahara DDS, PhD

The Impact of COVID-19 on Dental Anesthesiologists: An Online Survey of Board-Certified Dental Anesthesiology Specialists of the Japanese Dental Society of Anesthesiology

Takuro Sanuki DDS, PhD,
 Hidetaka Kuroda DDS, PhD,
 Uno Imaizumi DDS, PhD,
 Shota Tsukimoto DDS, PhD,
 Norika Katagiri DDS, PhD,
 Ayako Mizutani DDS, PhD,
 Mari Ohnaka DDS,
 Shinji Kurata DDS, PhD,
 Naotaka Kishimoto DDS, PhD, and
 Kanta Kido DDS, PhD

Tracheal Bronchus Detected During General Anesthesia: A Case Report

Toru Yamamoto DDS, PhD,
 Tatsuru Tsurumaki DDS, PhD,
 Hiroko Kanemaru DDS, PhD, and
 Kenji Seo DDS, PhD

Management of an Ingested Foreign Body in a COVID-Positive Patient

Tiffany Smith BS,
 Rachel Blum BS, and
 Raquel Rozdolski DMD
ANPR logo
AboutIssuesAuthor InformationSubscriptions

ADSA Society

eISSN: 1878-7177

ISSN: 0003-3006

Powered by PubFactory