ファジィ理論を用いた大型ヘリカル装置超電導コイルシステムのクエンチ検出
安達 弥真人二ノ宮 晃瓜生 芳久石郷岡 猛三戸 利行今川 信作柳 長門関口 温朗山田 修一
著者情報
ジャーナル フリー

2005 年 40 巻 3 号 p. 93-99

詳細
抄録

We have analyzed the state of the superconducting coil system in a LHD at NIFS (National Institute of Fusion Science) using a fuzzy logic theorem to detect quenching at an early stage. In this method, the “warning coefficient" of the coil system is calculated. As for the fuzzy variables, “effective stored heat" in the coil is introduced in addition to the voltage signal in order to improve quench detection and state estimation. The “effective stored heat" is an integrated value of the heat generated in the coil on the assumption that instantaneous heat in the conductor is continuously cooled by liquid helium. Experiments conducted using the LHD coils confirmed that quench alarm signals can be issued with sufficient lead time before quenching. On the other hand, in the case of small local disturbances, the system shows only a small increase in the caution level.