Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


American Journal of Health-System Pharmacy, Vol. 64, Issue 5, 531-535
Copyright © 2007 by American Society of Health-System Pharmacists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bussières, J.-F.
Right arrow Articles by Larocque, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bussières, J.-F.
Right arrow Articles by Larocque, D.

Notes

Program to monitor surface contamination by methotrexate in a hematology–oncology satellite pharmacy

Jean-François Bussières, Yves Théorêt, Sonia Prot-Labarthe and Diane Larocque

JEAN-FRANCOIS BUSSIERES, B.PHARM., M.SC., M.B.A., FCSHP, is Pharmacist, YVES THEORET, PH.D., is Pharmacologist; SONIA PROT-LABARTHE, D.PHARM., is Research Assistant; and DIANE LAROCQUE, B.PHARM., M.SC., is Pharmacist, Department of Pharmacy, Centre Hospitalier Universitaire Sainte-Justine, Montréal, Québec, Canada.

Address correspondence to Mr. Bussières at the Department of Pharmacy, Centre Hospitalier Universitaire Sainte-Justine, 3175 Côte-Ste-Catherine, Montréal, Québec H3T 1C5, Canada (jf.bussieres{at}ssss.gouv.qc.ca).


Purpose. The results of contamination monitoring during a one-year pilot period are described.

Summary. A hematology–oncology satellite pharmacy conducted contamination monitoring for one year, using methotrexate as the index marker. From January 12, 2005, to December 21, 2005, 40 sampling sessions occurred during which 238 wipe samples (excluding positive controls) were collected. Each week, seven wipe samples were prepared by pharmacy technicians. Samples were obtained from the blank reference (site 0), the external metallic window frame of the main biological safety cabinet (BSC) (site 1), the back of the phone receiver (site 2), the external surface of an i.v. solution bag that was inside the BSC the previous hour (site 3), a working surface used for the final packaging and labeling (site 4), and the floor of the preparation room (site 5). The sixth sample was a positive methotrexate control. The methotrexate was detected by a high-performance liquid chromatograph with a fluorometric detector. Five samples tested positive for methotrexate—two from site 1, one from site 2, one from site 4, and one from site 0 (the blank); the last finding was thought to have most likely been the result of an error or sample mix-up during the wipe-sampling procedures. Despite differences in the sampling methods used, the type of wetting solution used, and the volume of desorption solution, the results were consistent with the literature in terms of few positive results.

Conclusion. A program was developed to monitor surface contamination by methotrexate in a hematology–oncology satellite pharmacy.

Index terms: Antineoplastic agents; Compounding; Contamination; Control, quality; Methotrexate; Pharmacy, institutional, hospital

 



This article has been cited by other articles:


Home page
J Oncol Pharm PractHome page
S. Prot-Labarthe, R. Therrien, C. Demanche, D. Larocque, and J.-F. Bussieres
Pharmaceutical care in an inpatient pediatric hematopoietic stem cell transplant service
Journal of Oncology Pharmacy Practice, September 1, 2008; 14(3): 147 - 152.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Society of Health-System Pharmacists.