分析化学
Print ISSN : 0525-1931
タンデム質量分析法による金属表面保護剤中の界面活性剤の同定
神戸 久志渋江 俊道平沢 泉
著者情報
ジャーナル フリー

1999 年 48 巻 8 号 p. 797-801

詳細
抄録

The applicability of tandem mass spectrometry to the quality analysis of metal-surface protect surfactants without any pretreatment or purification of the sample solution was investigated. Three typical spectra were constructed and verified by FAB CID-MS/MS using sodium n-dodecylsulfate (anionic surfactant), tetradecyl dimethylbenzylammonium chloride (cationic surfactant) and heptaethylene glycol mono-n-dodecyl ether (nonionic surfactant) as a model. The FAB CID-MS/MS spectra of metal-surface protect surfactants provided useful structural information that analyte surfactants have a polyoxyethylene structure, which has been identified as a nonionic surfactant. The authors concluded that FAB CID-MS/MS will be a good analytical method for direct quality analysis without any pretreatment or purification of the metal-surface protect surfactant for industrial use.

著者関連情報
© The Japan Society for Analytical Chemistry
前の記事 次の記事
feedback
Top