Abstract
We evaluated a new restricted access media (RAM) precolumn for direct analysis of drugs in plasma using a column switching HPLC system. The new RAM material was prepared by the modification of the external surface of porous silica with hydrophilic methylcellulose (MC), followed by modification of the internal surface with octadecylsilane (ODS). The external surface of the MC-immobilized ODS silica material (MC-ODS) suppressed the adsorption of proteins, while the internal surface of MC-ODS retained various types of drugs, such as ketoprofen, propranolol, caffeine and atenolol in plasma samples. In addition, MC-ODS allowed direct analysis of drugs in a 1000-μL plasma sample to monitor trace amounts of analytes contained. Reduced efficiency and clogging of the MC-ODS precolumn and/or the analytical column were not observed even after the repetitive injection of plasma sample up to 40 mL. Our results indicated that the MC-ODS precolumn could be used in pharmacodynamic and clinical studies.
Similar content being viewed by others
References
I. H. Hagestam and T. C. Pinkerton, Anal. Chem., 1985, 57, 1757.
I. H. Hagestam and T. C. Pinkerton, J. Chromatogr., 1986, 351, 239.
S. E. Cook and T. C. Pinkerton, J. Chromatogr., 1986, 368, 233.
J. Haginaka, N. Yasuda, J. Wakai, H. Matsunaga, H. Yasuda, and Y. Kimura, Anal. Chem., 1989, 61, 2445.
K. Kimata, R. Tsuboi, K. Hosoya, N. Tanaka, and T. Araki, J. Chromatogr., 1990, 515, 73.
S. Vielhauer, A. Rudolphi, K. S. Boos, and D. Seidel, J. Chromatogr. B, 1995, 666, 315.
N. Nimura, H. Itoh, and T. Kinoshita, J. Chromatogr. A, 1995, 689, 203.
H. Wang, C. Desilets, and F. E. Regnier, Anal. Chem., 1992, 64, 2821.
D. E. Williams and P. K. Kabra, Anal. Chem., 1990, 62, 807.
J. Haginaka, J. Wakai, and H. Yasuda, J. Chromatogr., 1990, 535, 163.
J. Haginaka and J. Wakai, J. Chromatogr., 1992, 596, 151.
H. Yoshida, I. Morita, T. Masujima, and H. Imai, Chem. Pharm. Bull., 1982, 30, 2287.
H. Yoshida, I. Morita, G. Tamai, T. Masujima, T. Tsuru, N. Takai, and H. Imai, Chromatographia, 1984, 19, 466.
J. Hermansson, J. Chromatogr., 1983, 269, 71.
T. Miwa, M. Ichikawa, M. Tsuno, T. Hattori, T. Miyakawa, M. Kayano, and Y. Miyake, Chem. Pharm. Bull., 1987, 35, 682.
T. Miwa, T. Miyakawa, and Y. Miyake, J. Chromatogr., 1998, 457, 227.
J. Hermansson, A. Grahn, and I. Hermansson, J. Chromatogr. A, 1998, 797, 251.
Z. Yu and D. Westerlund, Chromatographia, 1998, 47, 299.
J. Haginaka and T. Murashita, J. Chromatogr., 1993, 620, 199.
Y. Oda, N. Asakawa, S. Abe, Y. Yoshida, and T. Sato, J. Chromatogr., 1991, 572, 133.
T. Umemura, R. Kitaguchi, K. Inagaki, and H. Haraguchi, Analyst, 1998, 123, 1767.
D. J. Gisch, B. T. Hunter, and B. T. Feibush, J. Chromatogr., 1988, 433, 264.
C. P. Desilets, M. A. Rounds, and F. E. Regnier, J. Chromatogr., 1991, 544, 25.
Z. Yu, D. Westerlund, and K-S. Boos, J. Chromatogr. B, 1997, 704, 53.
N. Asakawa, H. Ohe, M. Tsuno, Y. Nezu, Y. Yoshida, and T. Sato, J. Chromatogr., 1991, 541, 231.
Y. Oda, N. Asakawa, T. Kajima, Y. Yoshida, and T. Sato, J. Chromatogr., 1991, 541, 411.
J. Ayrton, G. J. Dear, W. J. Leavens, D. N. Mallet, and R. S. Plumb, Rapid Commun. Mass Spectrom., 1997, 11, 1953.
J-T. Wu, H. Zeng, M. Qian, B. L. Brogdon, and S. E. Unger, Anal. Chem., 2000, 72, 61.
K. K. Unger, “POROUS SILICA: Its Properties and Use as Support in Column Liquid Chromatography”, 1979, Elsevier Scientific Publishing Company, Amsterdam, 82.
V. Y. Davydov, A. V. Kiselev, and V. I. Lygin, Russ. J. Phys. Chem., 1963, 37, 243.
V. Ya. Davydov and A. V. Kiselev, Kolloidn. Zh., 1968, 30, 353.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Yamamoto, E., Murata, K., Ishihama, Y. et al. Methylcellulose-immobilized Reversed-phase Precolumn for Direct Analysis of Drugs in Plasma by HPLC. ANAL. SCI. 17, 1155–1159 (2001). https://doi.org/10.2116/analsci.17.1155
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.17.1155