Czech J. Anim. Sci., 2004, 49(5):226-230 | DOI: 10.17221/4304-CJAS

Airborne noise, structure-borne sound (vibration) and vacuum stability of milking systems

D. Nosal, E. Bilgery
2
1 Swiss Federal Research Station for Agricultural Economics and Engineering (FAT), Tanikon, Switzerland
2 BITEC Engineering, Romanshorn, Switzerland

Problems with milking and udder health can be attributed to the following causes: (1) sound intensity level (noise) > 65 dB in the milking area, (2) transmission of oscillation (vibration) > 0.3 m/s2 to the body of the cow in the milking parlour, (3) transmission of severe oscillation (vibration) into the vacuum system, (4) assembly and installation faults causing fluid flow problems and hence pressure fluctuations in the vacuum system. By combining technical alterations to a practical unit with the fitting of the Vibrations-schlucker®, it was possible to significantly improve vacuum stability. At the same time noise dropped to one quarter of the original level and vibration was reduced by a factor of five. A significantly reduced working time requirement testified to more pleasant conditions for humans and animals. The results show that the installation requirements according to ISO 5707 (1996) have gaps here. Further studies should specifically define the comfort limits for humans and animals in milking parlours.

Keywords: milking; stress; milking machine; air-borne noise; structure-borne noise; vacuum stability

Published: May 31, 2004  Show citation

ACS AIP APA ASA Harvard Chicago IEEE ISO690 MLA NLM Turabian Vancouver
Nosal D, Bilgery E. Airborne noise, structure-borne sound (vibration) and vacuum stability of milking systems. Czech J. Anim. Sci.. 2004;49(5):226-230. doi: 10.17221/4304-CJAS.
Download citation

References

  1. ISO 5707 (1996): Milking machine installations - Construction and performance, Second edition, 1996-07-01, 23 pp.
  2. ISO 6690 (1996): Milking machine installations - Mechanical tests, Second edition, 1996-12-15, 27 pp.
  3. ISO 2631-1 (1997): Vibrations et chocs mécaniques - Evaluation de l'exposition des individus à des vibrations globales du corps - Partie 1: Spécifications générales.
  4. Nosal D. (2000): Richtlinien für die Durchführung der Kontrolle von Melkanlagen, FAT, 19 pp.
  5. Nosal D., Bilgery E. (2001a): Effects of vibrations on the vacuum stability in milking equipment. In: Symposium Agricultural Engineering on the beginning of 21. Century. 06. 06. 2001, Sk-Nitra (mit Beitrag im Tagungsband).
  6. Nosal D., Bilgery E. (2001b): Vibration and Vacuum Stability in Milking Equipment. International Conference: Physiological and technical aspects of machine milking. 26./27. 06. 2001, Sk-Nitra (mit Beitrag im Tagungsband).
  7. Suva (Schweiz. Unfallversicherungsanstalt, Arbeitssicherheit) (1997): Gehörgefährdender Lärm am Arbeitsplatz. 3. Auflage, Februar 1997, 95 pp.

This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International (CC BY NC 4.0), which permits non-comercial use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.