Acessibilidade / Reportar erro

Determination of glucocorticoids using cosurfactants ultrasonic-thermostatic-assisted cloud point extraction followed by high performance liquid chromatography

Abstracts

A novel approach, cosurfactants ultrasonic-thermostatic-assisted cloud point extraction (CUS-CPE) combined with high performance liquid chromatography and ultraviolet detection (HPLC-UV) is developed for the analysis of glucocorticoids (beclometasone dipropionate (BD), hydrocortisone butyrate (HB) and nandrolone phenylpropionate (NPP)) in human urine samples. In this study, four different cloud point extraction (CPE) systems are discussed, including DC-193-nonanoic acid, DC-193-sodium sulfate, DC-193-lauric acid and the classic Triton X-100 sulfate systems. Among them, DC-193-sodium sulfate and the classic Triton X-100 sulfate systems has been studied in the past few years. Comparing with the first two systems, DC-193-nonanoic acid system had a lower cloud point (CP), little UV absorbance and it is less damaging to the column of three glucocorticoids in same surfactant concentration which was required for application as a pre-concentration process prior to HPLC. Phase diagrams were used to study the cavitation and mass transfer behaviors of the two phases on micelles of polyether type organic silicon surfactant, PEG-12 dimethicone (DC-193).The volumes of surfactant-rich phase obtained were very small (the enrichment factor (EF) was 35), which was much smaller and had a quick phase separating speed than that of Triton X-100 in the same surfactant concentration. Linearity was investigated from 1 to 350 ng mL-1. The limits of detection (LOD) thus estimated were 1.29 for BD, 2.67 for HB and 3.33 ng mL-1 for NPP, respectively. In proposed CPE step is rapid and effective to obtain recovery of three glucocorticoids higher than 85%, which is similar or better than literature reported data. The method was shown to be selective, linear, precise and reproducible and successfully applied for the analysis of glucocorticoids in human urine samples.

CUS-CPE; glucocorticoids; DC-193; human urine; HPLC-UV


Foi desenvolvida uma nova abordagem de extração no ponto nuvem assistida por cossurfactantes ultrassônicos-termostáticos (CUS-CPE), combinada à cromatografia líquida de alta eficiência e detecção por ultavioleta (CLAE-UV), para a análise de glicocorticoides (dipropionato de beclometasona (BD), butirato de hidrocortisona (HB) e fenilpropionato de nandrolona (NPP)) em amostras de urina humana. Neste estudo, quatro sistemas de extração diferentes no ponto nuvem (CPE) são discutidos, incluindo ácido nonanoico DC-193, sulfato de sódio DC-193, ácido láurico DC-193 e o clássico sulfato de Triton X-100. Entre eles, sulfato de sódio DC-193 e Triton X-100 têm sido estudados nos últimos anos. Comparando com os dois primeiros sistemas, o ácido nonanoico DC-193 teve um ponto nuvem (CP) mais baixo, pouca absorbância UV e provocou danos menores à coluna de três glicocorticoides na mesma concentração de agente tensoativo, necessária como processo de pré-concentração, prévio à CLAE. Diagramas de fase foram usados para estudar os comportamentos de cavitação e transferência de massa das duas fases em micelas de agente tensoativo de silicone orgânico do tipo poliéter, dimeticona PEG-12 (DC-193). Os volumes da fase rica em agentes tensoativos obtidos foram muito pequenos (o fator de enriquecimento (EF) foi 35), o qual é muito menor e apresenta uma fase de separação mais rápida do que para Triton X-100 na mesma concentração de agente tensoativo. A linearidade foi investigada entre 1 e 350 ng mL-1. Os limites de detecção (LOD) estimados foram 1,29 para BD, 2,67 para HB e 3,33 ng mL-1 para NPP, respectivamente. O sistema proposto é rápido e eficiente, com recuperação dos três glicocorticoides superior a 85%, o que é similar ou melhor do que os dados relatados na literatura. O método mostrou-se seletivo, linear, preciso e reprodutível, tendo sido aplicado com sucesso na análise de glicocorticoides em amostras de urina humana.


Determination of glucocorticoids using cosurfactants ultrasonic-thermostatic-assisted cloud point extraction followed by high performance liquid chromatography

Hui QinI; Gao Feng LiII; Nan ChenII; Ya Ling YangI,* * e-mail: yilyil8@163.com

IFaculty of Life Science and Technology, Kunming University of Science and Technology, 650500 Kunming, P. R. China

IITumor Hospital of Yunnan Province, 650106 Kunming, P. R. China

ABSTRACT

A novel approach, cosurfactants ultrasonic-thermostatic-assisted cloud point extraction (CUS-CPE) combined with high performance liquid chromatography and ultraviolet detection (HPLC-UV) is developed for the analysis of glucocorticoids (beclometasone dipropionate (BD), hydrocortisone butyrate (HB) and nandrolone phenylpropionate (NPP)) in human urine samples. In this study, four different cloud point extraction (CPE) systems are discussed, including DC-193-nonanoic acid, DC-193-sodium sulfate, DC-193-lauric acid and the classic Triton X-100 sulfate systems. Among them, DC-193-sodium sulfate and the classic Triton X-100 sulfate systems has been studied in the past few years. Comparing with the first two systems, DC-193-nonanoic acid system had a lower cloud point (CP), little UV absorbance and it is less damaging to the column of three glucocorticoids in same surfactant concentration which was required for application as a pre-concentration process prior to HPLC. Phase diagrams were used to study the cavitation and mass transfer behaviors of the two phases on micelles of polyether type organic silicon surfactant, PEG-12 dimethicone (DC-193).The volumes of surfactant-rich phase obtained were very small (the enrichment factor (EF) was 35), which was much smaller and had a quick phase separating speed than that of Triton X-100 in the same surfactant concentration. Linearity was investigated from 1 to 350 ng mL-1. The limits of detection (LOD) thus estimated were 1.29 for BD, 2.67 for HB and 3.33 ng mL-1 for NPP, respectively. In proposed CPE step is rapid and effective to obtain recovery of three glucocorticoids higher than 85%, which is similar or better than literature reported data. The method was shown to be selective, linear, precise and reproducible and successfully applied for the analysis of glucocorticoids in human urine samples.

Keywords: CUS-CPE, glucocorticoids, DC-193, human urine, HPLC-UV

ABSTRACT

Foi desenvolvida uma nova abordagem de extração no ponto nuvem assistida por cossurfactantes ultrassônicos-termostáticos (CUS-CPE), combinada à cromatografia líquida de alta eficiência e detecção por ultavioleta (CLAE-UV), para a análise de glicocorticoides (dipropionato de beclometasona (BD), butirato de hidrocortisona (HB) e fenilpropionato de nandrolona (NPP)) em amostras de urina humana. Neste estudo, quatro sistemas de extração diferentes no ponto nuvem (CPE) são discutidos, incluindo ácido nonanoico DC-193, sulfato de sódio DC-193, ácido láurico DC-193 e o clássico sulfato de Triton X-100. Entre eles, sulfato de sódio DC-193 e Triton X-100 têm sido estudados nos últimos anos. Comparando com os dois primeiros sistemas, o ácido nonanoico DC-193 teve um ponto nuvem (CP) mais baixo, pouca absorbância UV e provocou danos menores à coluna de três glicocorticoides na mesma concentração de agente tensoativo, necessária como processo de pré-concentração, prévio à CLAE. Diagramas de fase foram usados para estudar os comportamentos de cavitação e transferência de massa das duas fases em micelas de agente tensoativo de silicone orgânico do tipo poliéter, dimeticona PEG-12 (DC-193). Os volumes da fase rica em agentes tensoativos obtidos foram muito pequenos (o fator de enriquecimento (EF) foi 35), o qual é muito menor e apresenta uma fase de separação mais rápida do que para Triton X-100 na mesma concentração de agente tensoativo. A linearidade foi investigada entre 1 e 350 ng mL-1. Os limites de detecção (LOD) estimados foram 1,29 para BD, 2,67 para HB e 3,33 ng mL-1 para NPP, respectivamente. O sistema proposto é rápido e eficiente, com recuperação dos três glicocorticoides superior a 85%, o que é similar ou melhor do que os dados relatados na literatura. O método mostrou-se seletivo, linear, preciso e reprodutível, tendo sido aplicado com sucesso na análise de glicocorticoides em amostras de urina humana.

Introduction

Glucocorticoids have a long history of use in human and veterinary medicine.1 Beclometasone dipropionate (BD), hydrocortisone butyrate (HB) are epimeric synthetic glucocorticoids, and are employed frequently as antiinflammatory and antiallergic drugs. They are effective in a variety of diseases including ketosis, allergic reactions, pregnancy toxemia, shock and mastitis.2,3 However, the mechanisms regulating these effects are not fully understood. The determination of glucocorticoids in different human fluids, such as urine, is of great interest in medical diagnostics, especially for patients suffering from Parkinson's disease or phaeochromocytoma and stress. An early and accurate determination of the glucocorticoids concentration in urine could prevent unnecessary drug treatment.4

Therefore, accomplishment of sensitive, rapid and simple analytical methods of the glucocorticoids in human urine are paramount. Several HPLC (high performance liquid chromatography), LC-MS (liquid chromatography coupled to mass spectrometry) and electrochemical methods have been reported in the literature describing the analysis of glucocorticoids.5-13 Urine samples are usually enriched by optical fiber biosensor or solid-phase extraction by HPLC-MS/MS (high performance liquid chromatography-tandem mass spectrometry) method or voltammetric techniques.14,15

This work aimed at the development of cosurfactants ultrasonic-thermostatic-assisted cloud point extraction (CUS-CPE) for analysis of three glucocorticoids based on high performance liquid chromatography and ultraviolet detection (HPLC-UV). Non-ionic surfactant DC-193 was first used to extract and preconcentrate glucocorticoids in human urine. In the new process, glucocorticoids and DC-193 formed homogeneous solution, which was solubilized with nonionic surfactants micelle solution, then concentrated along with micelles into a surfactant-rich phase by phase separation after ultrasonic-thermostat over cloud point.16,17 However, the well-known nonionic surfactants, such as Triton X and PONPE series, had a high background absorbance in the ultraviolet or their fluorescence signals interfere in the fluorescent region, due to the presence of an aromatic moiety in their structure.18 Therefore, using a surfactant without UV absorbance or fluorescence signals was considered to be the best way to avoid the chromatographic overlapping. The DC-193-nonanoic acid system had little UV absorbance, so could be injected into the HPLC with UV detector directly without any pretreatment. Comparing with Triton X-100 sulfate system, it had higher EF and recovery in the same surfactant concentrations and high phase separating speed at the same time. The amount of nonanoic acid played a very important role in the phase separation and extraction. The results obtained by the CUS-CPE method were compared with four different systems (DC-193-nonanoic acid, DC-193-sodium sulfate, DC-193-lauric acid and the classic Triton X-100 sulfate systems) encompassing aspects such as equilibration temperature, incubation time, recovery, phase diagrams, enrichment factor and so on, and this study had been rarely reported in the literature.

Experimental

Materials and reagents

All reagents used were HPLC grade, and purified water from a Milli Q system (Millipore, Mil-ford, MA, USA) was used throughout the experiments. BD, HB and NPP were obtained from Sigma (St. Louis, Mo., USA). Standard stock solutions of BD, HB and NPP (nandrolone phenylpropionate) were prepared in methanol at a concentration of 1 mg mL-1. The structures of the three glucocorticoids and some characteristics are shown in Table 1. Methanol (HPLC grade) was obtained from Merck (Darmstadt, Germany). The non-ionic surfactant DC-193 (Acros Organics, New Jersey, USA) was used without further purification, to prepare 10% (v/v) aqueous solutions. Nonanoic acid was obtained from Sigma (St. Louis, Mo., USA).

Apparatus

Chromatographic separation and evaluation were performed on an HPLC system consisting of a vacuum degasser, an auto sampler, a quaternary pump, and a diode array detector (Agilent 1200 Series, Agilent Technologies (California, USA)). A thermostatic SHY-2A water bath (Tianjin, China) was used to study temperature effects on CPE. An ultrasonic bath from Kunshan ultra-sonic instrument plant (Jiangsu, China) was used for extraction of samples. A 80-2 centrifuge (Shanghai, China) was used for complete phase separation.

Chromatographic conditions

The HPLC-UV system was used in the present study. Separation was carried out on a reversed phase Agilent TC-C18 analytical column (150 mm x 4.6 mm, i.d, 5 µm). 100% acetonitrile and 0.1% formic acid were used as mobile phase with the gradient program as follows: 80% acetonitrile (0 to 6 min), ramped to 90% acetonitrile (6.5 to 8 min). The flow rate was maintained at 0.8 mL min-1. The injection volume was 10 µL. The system was allowed to stabilize for 1 to 2 min under the initial conditions. The prepared mobile phase was filtered and degassed using ultrasonic agitation. The column temperature was maintained at 35 ºC and the wavelength of the UV Detector was at a fixed wavelength of 240 nm.

Cloud point procedure

Extraction from aqueous samples

A 2 mL aliquot of the solution containing different concentrations of glucocorticoids (BD, HB and NPP) was placed in centrifuge vials. Then 2.5 mL of 10% (v/v) of DC-193 stock solution and 1 mL of 100% (v/v) of nonanoic acid were added, and the mixtures were diluted with doubly distilled water to 10 mL. The mixture solution was left standing for 5 min, and incubated into an ultrasonic water bath performed at 35 kHz of ultrasound frequency and 65 ºC for 30 min. Then the phase were separated by centrifugation for 3 min at 4000 rpm. The lower water phase was carefully removed by using a syringe with a long needle that passed through the upper surfactant-rich phase. The surfactant-rich phase was left in the tube and diluted to 0.5 mL with acetonitrile. Therefore, EF of about 35 was finally obtained, and 10 µL of the surfactant-rich phase solution were injected into the HPLC system. A diagramatic sketch of CUS-CPE is shown in Figure 1.


Sampling and pretreatment

Urine samples were obtained from healthy volunteers in a certified laboratory of clinical analysis. Urine samples were stored at -18 ºC until further processing for each of the analytical methodologies implemented in this work. An amount of 5 mL of urine were added to a 50 mL flask and diluted to volume with purified water. Each prepared sample was adjusted to a pH value of approximately 6.5 with 0.5 mol L-1 of NaOH. The solution was transferred to a test tube, and was centrifuged at 4000 rpm for 30 min. Then the supernatant fluid was diluted with purified water to a final volume of 10 mL. The surfactant-rich phase was separated as described previously in the "Extraction from aqueous samples" section.

Results and Discussion

Optimization of the CPE conditions

The cloud point temperature of DC-193 is 95 or 96 ºC, but the cloud point can be reduced to 65 oC through a series of optimization of conditions. Therefore, DC-193 is a better non-ionic surfactant in the cloud point extraction.

Comparison of data of four studied systems

Some additive molecules (cosurfactants) were adsorbed on the surface of micelles to inhibit the micellization resulting in the increase of CP, while the molecules of the latter could be solubilized in the layer of micelles to lead the micelles to swell, resulting in the decrease of CP.16,19,20 In this work, four studied systems are used to assess this behavior and the organic acids are considered as cosurfactants. The results reveal that the nonanoic acid has a better effect than lauric acid at the same concentration. (see Figure 2).


The CP that could be reduced from 96 ºC to 65 ºC was significantly affected by the amount of organic acids. Lauric acid and nonanoic acid are saturated straight chain monoacids. When the amount of -OH was sufficient, most molecules which were soluble in micellar palisade layer existed around the non-ionic surfactant polar groups. The hydration degree of the surfactants was reduced due to the steric effect, which led to a lower CP. When a large number of -OH was present, part of it wasadsorbed on the micellar palisade layer and interface.20 The appropriate concentration was at 10%, which was adopted as the optimum amount to achieve best analytical signals and extraction efficiency. By comparison of two systems, DC-193 nonanoic acid system was selected in the process (see Figure 3).


Each sample was assayed six times under identical experimental conditions to confirm the reproducibility of analytical data. Figure 4 shows typical HPLC chromatograms of extracted and pre-concentrated glucocorticoids in the four studied systems. It was found that the DC-193 nonanoic acid system is superior to the other three studied systems (DC-193-sodium sulfate, DC-193-lauric acid and the classic Triton X-100 sulfate systems) in recovery, EF and assay sensitivity. The comparison of another three studied systems is shown in Figure 4 and Table 2.


Characteristic performance data

Effect of the concentration of surfactants

The theoretical pre-concentration factor depends on the concentration of surfactant. Aqueous solutions containing a mixture of standard glucocorticoids (50 ng mL-1 each) were extracted by CUS-CPE with different concentrations of DC-193 in the range of 0.5-6% (v/v). The effect of the concentration of surfactant was examined and the results are presented in Figure 5.


The highest recovery is at 2.5% concentration of DC-193 solution. Based on these experimental results, 2.5% of DC-193 was adopted as the optimum amount to achieve best analytical signals and extraction efficiency. The other parameters, including acid, equilibration temperature and time, were optimized in subsequent experiments.

Effect of temperature and equilibrium time

It was found that the effects of various temperatures on the extraction recovery was a key for CPE. If the temperature was lower than the CP, two phases could not be formed.21 Briefly, the tubes were kept at different temperatures ranging from 55 ºC to 85 ºC for 30 min maintained in a water bath. It was found that two phases could be formed quickly for 30 min when the temperature was greater than or equal to 65 ºC. At the same time, recovery was examined under different temperatures. The results showed that the recovery increases from 55 to 65 ºC and decreases quickly thereafter (Figure 6). However, part of the analytes may be volatilized if the temperature is too high.


For further experiments, 65 ºC was therefore used as the temperature for extraction. The effect of heating time was also studied to determine the maximum recovery. It was observed that beyond 30 min there was a decrease on recovery for the entire temperature range studied. It was therefore decided to carry out the extraction of glucocorticoids at 65 ºC for 30 min as these conditions provided the maximum recovery (Figure 7).


Effect of the amount of organic acid added

The CP was significantly affected by the amount of organic acids.19 The CP continued to decline, but it had little change after 65 ºC. The appropriate concentration was at 10%, which was adopted as the optimum amount to achieve best analytical signals and recovery. An amount of 10% (v/v) of nonanoic acid was chosen in the process (see Figures 2, 3, 6).

CPE phase diagrams

Phase behavior of an aqueous nonionic surfactant micelle solution is very sensitive to temperature.22,23 Above a certain temperature, a single phase nonionic surfactant micelle aqueous solution separates into a dilute phase and a surfactant-rich phase or coacervate phase.

The surfactant-rich phase volume percentage (Vs/Vs+Vw) of glucocorticoids were used to evaluate the CUS-CPE performance, where Vs was the volume of the surfactant-rich phase and Vw was the volume of the water phase. Figure 8 shows the phase separation process under the heating condition in different time of two surfactant solutions about four studied systems. The volume of the surfactant-rich phase was increased gradually with the extension of heating time to achieve the ultimate stable state. The interaction between solute and surfactant was treated as the difference of density and the influence of thermal motion in the interior or outer palisade layers of the micelles. In most cases, after 30-40 min the volume of the surfactant-rich phase could achieve stable state. Figure 8(a-d) showed that different time of surfactant solutions, activities and ultrasonic joined influenced the phase separation process. As could be seen from Figure 8a, compared with the curves b-d, the phase equilibrium time was reduced to 30 min by adding nonanoic acid and ultrasonic bath. Phase separation process of DC-193 micelles could be accelerated with CUS-CPE effectively at 65 ºC for 30 min, which could be got in the clear separation interface. It is found that CP was been reduced significantly after adding nonanoic acid compared with the original CP. EF of about 35 was finally obtained. The EF could be expressed as: EF = (M0/V0)/(M1/V1), where EF was enrichment factor, M0 was the amount of glucocorticoids added before enrichment, V0 was the volume of solution before enrichment and M1 and V1 represented the amount of glucocorticoids added and the volume of solution after enrichment, respectively.


Interferences

According to the previous experiments, potential interfering glucocorticoids in human urine samples have no obvious interferences. In addition, peak retention time is almost unchanged as compared with Standard whether in water or human urine. The results are shown in Table 3.

Application analysis

The analytical results obtained by the proposed method were compared with those obtained by the methods used in the literature for analyzing glucocorticoids in urine samples. Under the optimum conditions as described above, the results presented indicated that the proposed method provided similar or higher sensitivity. The LOD thus estimated was 1.29 ng mL-1 for BD, 2.67 ng mL-1 for HB , 3.33 ng mL-1 for NPP, respectively (Table 4).

The LC-MS/MS technique serves as an effective analytical tool for analyzing glucocorticoids, but it is expensive and could not be easily obtained from common analytical laboratory when it was compared with HPLC-UV.24 The recovery of glucocorticoids that was rapid and effective to attain 85% by CUS-CPE was similar or better than literature reported data (Table 5).

Stability and accuracy

The recoveries for the addition of different concentrations of glucocorticoids to samples are in the range of 85.1 to 88.5%, and the results are shown in Tables 6 and 7. The background response in blank sample was subtracted. The stability of glucocorticoids was evaluated by determining a sample repeatedly at 0, 6, 12 and 24 h with a represents means of per concentration level in each day (RSD) < 3% (n = 6), which shows that the derivatives of glucocorticoids had a good stability within 24 h.

A total of 300 mL healthy volunteers diluted urine sample was divided into 60 portions of 5 mL each. All these portions were detected throughout 3 days, 18 portions per day. Then the intra-assay variation and the inter-assay variation of the method were determined, whose RSD% were both below 3%. The recovery was determined by measuring a blank urine sample and the same urine sample enriched with glucocorticosteroids at three concentration levels. Results were shown in Tables 6 and 7.

Validation of the method

To assess the practical applicability of the proposed method, the optimized extraction conditions were adopted to evaluate performance characteristics such as LOD and limit of quantification (LOQ). Linearity was investigated from 1-350 ng mL-1 (each of the glucocorticoids at 1, 5, 25, 50, 100, 150 and 350 ng mL-1) by plotting the HPLC-UV peak areas of mixed standard solution against the concentrations in the spiked actual samples. The data were processed using Analyst software (Applied-Biosystems). For the quantification of the glucocorticoids in the actual samples, weighted least-squares regression analysis of the standard curves were used. The correlation coefficients were determined to be 0.9996 which are acceptable for trace analysis. Thus, a proportional relationship can be calculated between the amount of analytes extracted and the concentration of the samples. The LOQ was determined at S/N = 10, which was 5.16, 11.68 and 14.32 ng mL-1 for BD, HB and NPP, respectively (Table 4). The low LOQ value is sufficient to measure the concentration of glucocorticoids in urine samples.

Conclusions

CUS-CPE using DC-193 non-ionic surfactants has been proven to be an effective pre-concentration method that is specific and sensitive for the analysis of glucocorticoids and potentially for other hydrophobic compounds by HPLC-UV. Several points are worth noting: (i) DC-193-nonanoic acid system had higher recovery, EF, good linearity and repeatability; (ii) the process of the CUS-CPE also reveals that the nonanoic acid acts as a cosurfactant that has influence on CP. The effect of the CP temperature may be related to hydrophilicity and space structure of organic acids and solubilization position;20 (iii) the phase separation and variation of the surfactants DC-193 mixtures with nonanoic acid also differs dramatically from the phase diagrams.

In addition, four systems (DC-193-nonanoic acid, DC-193-sodium sulfate, DC-193-lauric acid and the classic Triton X-100 sulfate system) has been compared containing recovery, EF, the mechanism of the lower CP from the addition of organic acid. Hence, the method is a useful tool for official residue control analyses and is used as such in our laboratory.

Acknowledgments

This study was supported by the Tumor Hospital of Yunnan Province, Kunming 650106, China.

Submitted: August 23, 2012

Published online: December 7, 2012

  • 1. Wu, F. K.; Jiagen, L. V.; Talanta 2007,72,1811.
  • 2. Cvoro, A.; Korac, G.; Cell Biol. Int. 2003,27,403.
  • 3. Baynes, T. M.; Jimenez, A. L.; Craigmill, J. E.; Riviere, R.; Toxicol. Appl. Pharmacol. 1999,29,287.
  • 4. Lurdes, I. B.; Filipe, D. P.; Freitas, A. P.; Rocha-Santos, A. C.; Talanta 2009,80,853.
  • 5. Santos-Montes, A.; Gasco-Lopez, A. I.; Zquierdo-Hornillos, R. I.; J. Chromatogr., A 1994,652,83.
  • 6. Chen, Q.; Zielinski, D.; Chen, J.; Koski, A.; Werst, D.; Nowak, S.; J. Pharm. Biomed. Anal. 2008,48,732.
  • 7. Malone, E. M.; Elliott, C. T.; Regan, L.; Anal. Chim. Acta 2009,637,112.
  • 8. Beitollahi, H.; Karimi-Maleh, H.; Khabazzadeh, H.; Anal. Chem. 2008,80,9848.
  • 9. Hamid, R.; Zare, N. N.; Sens. Actuators, B 2010,143,666.
  • 10. McWhinney, B. C.; Ward, G.; Hickman, P. E.; Clin. Chem. (Washington, DC, U. S.) 1996,42,979.
  • 11. Collado, M. S.; Robles, J. C.; Zan, M. D.; Camara, M. S.; Mantovani, V. E.; Goicoechea, H. C.; Int. J. Pharm. 2001,229,205.
  • 12. Wasch, K. D.; Brabander, H. D.; Courtheyn, D.; Peteghem, C. V.; Analyst (Cambridge, United Kingdom) 1998,123,2415.
  • 13. Shibasaki, H.; Furuta, T.; Kasuya, Y.; J. Chromatogr., B: Anal. Technol. Biomed. Life Sci. 1997,692,7.
  • 14. Tlgye, D.; Virenderk, S.; Lorna, K.; J. Chromatogr., B: Anal. Technol. Biomed. Life Sci. 2010,878,1471.
  • 15. Balaji, K.; Raghunadha Reddy, G. V.; Madhusudana Reddy, T.; Afr. J. Pharm. Pharmaco. 2008,2,157.
  • 16. Yao, B. J.; Yang, L.; Sep. Sci. Technol. 2009,44,476.
  • 17. Yao, B. J.; Yang, L.; Ind. Eng. Chem. Res. 2008,47,3949.
  • 18. Yao, B. J.; Yang, L.; Qiong, H.; Akita, S.; Chin. J. Chem. Eng. 2007,15,468.
  • 19. Su, X. J.; J. Anhui Agr. Sci. 2011,239,5814.
  • 20. Shen, M.; Guo, R.; Liu, Z. M.; Chem. J. Chinese Univ 1996,10,1603.
  • 21. Liang, R.; Wang, Z. L.; Xu, J. H.; Li, W.; Qi, H. S.; Sep. Purif. Technol. 2009,66,248.
  • 22. Chen, M.; Xia, Q. H.; Liu, M. S.; Yang, Y. L.; J. Food Sci. 2011,76,1.
  • 23. Baig Jameel, A.; Kazi Tasneem, G.; Shah Abdul, Q.; Anal. Chim. Acta 2009,651,57.
  • 24. Wu, M.; Zheng, X. H.; Qi, S. L.; Phys. Test. Chem. Anal. 2010,46,1282.
  • 25. Zhu, X. S.; Liao, J.; Huang, X. J.; China Pharm 2009,20,2463.
  • 26. Salem, I. I.; Alkhatib, M.; Najib, N.; J. Pharm. Biomed. Anal. 2011,56,983.
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      18 Dec 2012
    • Date of issue
      Nov 2012

    History

    • Received
      23 Aug 2012
    • Accepted
      07 Dec 2012
    Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
    E-mail: office@jbcs.sbq.org.br