IEICE Transactions on Electronics
Online ISSN : 1745-1353
Print ISSN : 0916-8524
- Selected Papers from International Session on Electro-Mechanical Devices 2014 (IS-EMD2014) and Other Recent Research Results -
Influences of Contact Opening Speeds on Break Arc Behaviors of AgSnO2 Contact Pairs in DC Inductive Load Conditions
Makoto HASEGAWA
Author information
JOURNAL RESTRICTED ACCESS

2015 Volume E98.C Issue 9 Pages 923-927

Details
Abstract

Break operations of DC inductive (L=20mH) load currents up to about 5A with 14V were conducted in air with AgSnO2 contact pairs under different contact opening speeds, first up to 20mm/s and then to 200mm/s. Average break arc duration at each current level was calculated under the respective opening speeds. While break arc durations became shorter with increases in the opening speeds at larger current levels, such reduction tendencies were less significant with an increase of the contact opening speed from 20mm/s to 200mm/s, even when operated to break a load current of 5A. Both load current levels and contact opening speed levels seem to exhibit certain roles for realizing arc shortening effects.

Content from these authors
© 2015 The Institute of Electronics, Information and Communication Engineers
Previous article Next article
feedback