Skip to main content
Log in

Novel Glucose Biosensor Based on the Microcantilever

  • Published:
MRS Online Proceedings Library Aims and scope

Abstract

We report a novel technique for micromechanical detection of biologically relevant glucose by immobilization of glucose oxidase (GOx) onto a microcantilever surface. Microfabricated cantilevers have recently attracted considerable interest in the development of a wide range of novel physical, chemical, and biological sensors. This paper describes the combination of this novel technology with enzyme specificity to construct a highly selective glucose biosensor. The enzyme-functionalized microcantilever undergoes bending due to a change in surface stress induced by the reaction between glucose and the GOx immobilized on the cantilever surface. The common interferents for glucose detection in other detection schemes have been tested and have shown no effect on the measurement of blood glucose level by this technique.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. T. Thundat, G. Y. Chen, R. J. Warmack, D. P. Allison and E. A. Wachter, Anal. Chem. 67, 519, (1996)

    Article  Google Scholar 

  2. G. Y. Chen, T. Thundat, E. A. Wachter and R. J. Warmack, J. Appl. Phys. 77, 3618, (1995)

    Article  CAS  Google Scholar 

  3. X. Xu, T. Thundat, G. Brown and H. Ji, Anal. Chem. 74, 3611, (2002)

    Article  CAS  Google Scholar 

  4. F. J. Preissing, J. Appl. Phys, 66, 4262, 1989.

    Article  Google Scholar 

  5. K. M. Hanson, H. Ji, G. Wu, R. Datar, R. Cote, A. Majumdar and T. Thundat, Anal. Chem. 73, 1567, (2001)

    Article  Google Scholar 

  6. J. Fritz, M. K. Baller, H. P. Lang, H. Rothuizen, P. Vettiger, E. Meyer, H. J. Güntherodt, Ch. Gerber and J. K. Gimzewski, Science, 288, 316, (2000)

    Article  CAS  Google Scholar 

  7. G. Wu, R. Datar, K. Hanson, T. Thundat, R. Cote and A. Majumdar, Nature Biotechnology, 19, 856, (2001)

    Article  CAS  Google Scholar 

  8. K. Stevenson, A. Mehta, P. Sachenko, K. Hanson and T. Thundat, Langmuir, 18, 8732, (2002)

    Article  CAS  Google Scholar 

  9. G. S. Wilson and Y. Hu, Chem. Rev, 100, 2693, (2000)

    Article  CAS  Google Scholar 

  10. J. Wang, Electroanal. 13, 983, (2001)

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pei, J., Tian, F. & Thundat, T. Novel Glucose Biosensor Based on the Microcantilever. MRS Online Proceedings Library 776, 1121 (2003). https://doi.org/10.1557/PROC-776-Q11.21

Download citation

  • Published:

  • DOI: https://doi.org/10.1557/PROC-776-Q11.21

Navigation