Title: Analytical Investigation of Thermal Performance of Precast Concrete Three-Wythe Sandwich Wall Panels
Date: July-August, 2004
Volume: 49
Issue: 4
Page number: 88-101
Author(s): Byoung-Jun Lee, Stephen Pessiki
https://doi.org/10.15554/pcij.07012004.88.101

Click here to access the full journal article

Abstract

Precast concrete sandwich wall panels are commonly constructed of two wythes of concrete separated by a layer of thermal insulation. In these two-wythe panels, solid concrete regions which extend  directly through the entire thickness of the panel are often provided with embedded hardware for lifting, handling, and connections, or to provide composite action. These solid concrete regions have a significant adverse impact on the thermal performance of the panels. This research was directed towards the development of precast concrete three-wythe sandwich wall panels with improved thermal and structural performance. A three-wythe panel has three concrete wythes and two insulation layers, and all three concrete wythes are connected by solid concrete regions that are staggered in location so that no concrete path extends directly through the entire thickness of the panel. Practical panel configurations of three-wythe panels were  developed, and their thermal performance was evaluated by estimating   thermal resistance (R-value) using finite element method. 

References

1. Gabor, L., “Thermal Steady State Analysis,” Build International, V. 4, No. 1, January-February 1971, PP. 58-63.

2. McCall, W. C., “Thermal Properties of Sandwich Panels,” Concrete International, V. 7, No. 1, January 1985, Pp. 35-41.

3. Holman, J. P., Heat Transfer (Fifth Edition), McGraw-Hill Book Company, New York, NY, 1981, 570 pp.

4. PCI Committee on Precast Sandwich Wall Panels, “State-of the-Art of Precast/Prestressed Sandwich Wall Panels,” PCI JOURNAL, V. 42, No. 2, March-April 1997, pp. 92-134.

5. Kosny, J., Childs, P., and Desjarlais, A., “Thermal Performance of Prefabricated Concrete Sandwich Wall Panels,” Oak Ridge National Laboratory Building Technology Center, Oak Ridge, TN, 1999,  44 PP.

6. ASTM, “ASTM C236-89: Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box,” Annual Book of ASTM Standards, V. 04.06,  American Society for Testing and Materials, West Conshohocken, PA, 2001.

7. Lee, B., “Development of a Precast Prestressed Concrete Three-Wythe Sandwich Wall Panel,” Ph.D. Dissertation, Department of Civil and Environmental Engineering, Lehigh University, Bethlehem,  PA, May 2003, 373 Pp.

8. Lee, B., and Pessiki, S., “Development of a Precast Prestressed Concrete Three-Wythe Sandwich Wall Panel,” ATLSS Report No. 03-05, Lehigh University, Bethlehem, PA, April 2003, 294 pp.

9. ASHRAE, ASHRAE Handbook - Fundamentals (1-P Edition), American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, 1997.

10. PCI Design Handbook: Precast and Prestressed Concrete, Fifth Edition, Precast/Prestressed Concrete Institute, Chicago, IL, 1999.

11. Lee, Y., “Development of the Characteristic Section Method to Estimate R-Values of Precast Concrete Sandwich Wall Panels,” M.S. Thesis, Department of Civil and Environmental Engineering,  Lehigh University, Bethlehem, PA, May 2003, 102 pp.

12. Lee, Y., and Pessiki, S., “Development of the Characteristic Section Method to Estimate R-Values of Precast Concrete  Sandwich Wall Panels,” ATLSS Report No. 03-06, Lehigh University,  Bethlehem, PA, April 2003, 73 pp.

13. SAP 90 - Heat Transfer User Manual, Computer and Structures Inc., Berkeley, CA, 1990.

14. Snyder, M. K., “Heat Transfer Measurements of Corewall Insulated Sandwich: Prestressed Concrete Wall Panel System with 2-in. Thick Factory Installed 1-pcf Polystyrene Bead Board Insulation,”  Butler Manufacturing Company Research Center, Grandview, MO, 1980, 13 pp.

15. Shu, L. S., Fiorato, A. E., and Howanski, J. W., “Heat Transmission Coefficients of Concrete Block Wall with Core Insulation,” Proceedings of the ASHRAE/DOE-ORNL Conference, Thermal  Performance of the Exterior Envelopes of Buildings, ASHRAE SP28, 1979, pp. 421-435.