Clinical Investigation of Aortic Insufficiency by Means of Pulsed Doppler Echocardiography
Masao TOGUCHISatoshi ICHIMIYAKiyoshi YOKOINorio HIBITadashi KAMBE
Author information
JOURNAL FREE ACCESS

1981 Volume 22 Issue 4 Pages 537-550

Details
Abstract

Pulsed Doppler echocardiography (PDE) was performed on 41 patients with aortic insufficiency (AI), isolated or associated with other cardiac diseases, using an ATL 500A pulsed Doppler system. The diagnosis was confirmed by angiocardiography in 25 cases. The purpose of the present study was to analyze the disturbed flow due to AI, to investigate the sensitivity of PDE to this lesion, and to compare with the angiographic severity of AI (Sellers). The transducer was placed on the left sternal border and the flow pattern was recorded at the aortic valve orifice and the proximal and distal left ventricular outflow tract (LVOT), using a strip chart recorder at a paper speed of 100mm/sec
The specific feature of AI was a widely dispersed dot pattern which began at the aortic valve closure and extended to late diastole. The severity of AI was graded by supravalvular aortogram in 25 patients. In grades I and II, the abnormal dot pattern due to AI was mostly detected at the aortic valve orifice and the distal LVOT, but it was rather difficult to detect the disturbed flow at the proximal LVOT. In contrast, in grades III and IV, the disturbed flow was recorded at all the sampling sites; with severe aortic regurgitation, it was detected at a wider range in the left ventricular cavity
In grades I and II, the abnormal dot dispersion at the proximal LVOT was not so large at its onset in diastole but it tended to increase after the mitral valve opening, whereas in the majority of patients of grades III and IV, a large dot dispersion was recognized from its onset to late diastole
The typical flow pattern due to AI was detected at the LVOT in 38 out of 41 patients (92.7%). Moreover, it was detected in all the patients with angiographically proved AI except for 1 case of grade I (96.0%)