Deformation Measurement of a Driven Pile Using Distributed Fibre-optic Sensing

  • Christoph Monsberger EMAIL logo , Helmut Woschitz and Martin Hayden

Abstract

New developments in distributed fibre-optic sensing allow the measurement of strain with a very high precision of about 1 µm / m and a spatial resolution of 10 millimetres or even better. Thus, novel applications in several scientific fields may be realised, e. g. in structural monitoring or soil and rock mechanics. Especially due to the embedding capability of fibre-optic sensors, fibre-optic systems provide a valuable extension to classical geodetic measurement methods, which are limited to the surface in most cases.

In this paper, we report about the application of an optical backscatter reflectometer for deformation measurements along a driven pile. In general, pile systems are used in civil engineering as an efficient and economic foundation of buildings and other structures. Especially the length of the piles is crucial for the final loading capacity. For optimization purposes, the interaction between the driven pile and the subsurface material is investigated using pile testing methods. In a field trial, we used a distributed fibre-optic sensing system for measuring the strain below the surface of an excavation pit in order to derive completely new information.

Prior to the field trial, the fibre-optic sensor was investigated in the laboratory. In addition to the results of these lab studies, we briefly describe the critical process of field installation and show the most significant results from the field trial, where the pile was artificially loaded up to 800 kN. As far as we know, this is the first time that the strain is monitored along a driven pile with such a high spatial resolution.

Acknowledgements

We would like to thank the companies Keller Grundbau GmbH (Dr. V. Racansky) for the opportunity to realize this project, and Brugg Cables AG for their support.

References

[1] Brugg, (2012). Data Sheet: BRUsens strain V4. Vers. 2012 / 06 / 19 Rev. 01 TH, Brugg Cables AG, Brugg, CH, 1 p.Search in Google Scholar

[2] England, M., (2008). Review of methods of analysis of test results from bi-directional static load tests. Proc. 5th Int. Symp. on Deep Foundations on Bored and Auger Piles (BAP V), Ghent, Belgium, 5 p.10.1201/9780203882870.ch22Search in Google Scholar

[3] Hayden, M. and Kirchmaier, Th., (2010). Pile HAY-Proof-System® (Pile H-P-S) – Neuartiges System für statische Probebelastungen an schlanken Pfählen. Proc. 25th Christian Veder Colloquium, Graz University of Technology, 22 p.Search in Google Scholar

[4] ISO / BIPM, (1995). Guide to the Expression of Uncertainty in Measurement, International Organisation of Standards, Switzerland.Search in Google Scholar

[5] Kreger, S. T., Gifford, D. K., Froggatt, M. E., Soller, B. J. and Wolfe, M. S., (2006). High resolution distributed strain or temperature measurements in single-and multi-mode fiber using swept-wavelength interferometry. In: Optical Fiber Sensors, Optical Society of America, Washington DC, USA, pp. ThE42.Search in Google Scholar

[6] Kreger, S. T., Sang, A. K., Gifford, D. K. and Froggatt, M. E., (2009). Distributed strain and temperature sensing in plastic optical fiber using Rayleigh scatter. In: SPIE Defense, Security and Sensing, International Society for Optics and Photonics, Bellingham, USA, pp. 73160A–73160A.Search in Google Scholar

[7] Luna, (2014a). Data Sheet: Optical Backscatter Reflectometer (Model OBR 4600). Ver. LTOBR4600 REV. 004 02 / 13 / 2014, Luna technologies Inc., Roanoke, USA, 1 p.Search in Google Scholar

[8] Luna, (2014b). User Guide: Optical Backscatter Reflectometer Model OBR 4600. Ver. User Guide 5, OBR 4600 Software 3.6, Luna technologies Inc., Roanoke, USA, 230 p.Search in Google Scholar

[9] Osterberg, J. O., (1998). The Osterberg Load Test Method for Drilled Shafts and Driven Piles – The First Ten Years. 7th Int. Conf. and Exhibition on Piling and Deep Foundations, Vienna, Austria, 17 p.Search in Google Scholar

[10] Soller, B. J., Wolfe, M. S. and Froggatt, M. E., (2005). Polarization resolved measurement of Rayleigh backscatter in fiber-optic components. OFC/NFOEC Technical Digest, paper NWD 3, Los Angeles, USA, 6 p.Search in Google Scholar

[11] Wuilpart M., (2011). Rayleigh scattering in optical fibers and applications to distributed measurements. In: Thévanez, L. (ED.), Advanced Fibre Optics: Concepts and Technology, EPFL Press, Lausanne, CH, pp. 207–262.Search in Google Scholar

[12] Woschitz, H., Klug, F. and Lienhart, W., (2015). Design and calibration of a fiber optic monitoring system for the determination of segment joint movements inside a hydro power dam. IEEE J. of Lightwave Tech.33, Issue 12: 2652–2657.Search in Google Scholar

Received: 2015-11-19
Accepted: 2015-12-3
Published Online: 2016-3-31
Published in Print: 2016-3-1

© 2016 Walter de Gruyter GmbH, Berlin/Munich/Boston

Downloaded on 8.6.2024 from https://www.degruyter.com/document/doi/10.1515/jag-2015-0021/html