Action Sport Cameras as an Instrument to Perform a 3D Underwater Motion Analysis

Abstract

Action sport cameras (ASC) are currently adopted mainly for entertainment purposes but their uninterrupted technical improvements, in correspondence of cost decreases, are going to disclose them for three-dimensional (3D) motion analysis in sport gesture study and athletic performance evaluation quantitatively. Extending this technology to sport analysis however still requires a methodologic step-forward to making ASC a metric system, encompassing ad-hoc camera setup, image processing, feature tracking, calibration and 3D reconstruction. Despite traditional laboratory analysis, such requirements become an issue when coping with both indoor and outdoor motion acquisitions of athletes. In swimming analysis for example, the camera setup and the calibration protocol are particularly demanding since land and underwater cameras are mandatory. In particular, the underwater camera calibration can be an issue affecting the reconstruction accuracy. In this paper, the aim is to evaluate the feasibility of ASC for 3D underwater analysis by focusing on camera setup and data acquisition protocols. Two GoPro Hero3+ Black (frequency: 60Hz; image resolutions: 1280×720/1920×1080 pixels) were located underwater into a swimming pool, surveying a working volume of about 6m3. A two-step custom calibration procedure, consisting in the acquisition of one static triad and one moving wand, carrying nine and one spherical passive markers, respectively, was implemented. After assessing camera parameters, a rigid bar, carrying two markers at known distance, was acquired in several positions within the working volume. The average error upon the reconstructed inter-marker distances was less than 2.5mm (1280×720) and 1.5mm (1920×1080). The results of this study demonstrate that the calibration of underwater ASC is feasible enabling quantitative kinematic measurements with accuracy comparable to traditional motion capture systems.

Introduction

Motion capture systems are traditionally adopted to reconstruct the movements of animals and humans in different applications such as biomechanics [12], sport gesture analysis [37], rehabilitation [89] and clinics [1011]. However, optoelectronics and electromagnetic devices, mainly devoted to laboratory analysis, feature high costs and are not designed for both outdoor and underwater usage. Qualisys company distributes a video-based commercial system [12], specifically designed for underwater measurements using devoted illumination to enhance image quality. However, cameras still demand cables and the system is very expensive.

An alternative video-based technology is represented by action sport cameras (ASC), which are currently used mainly for recreational purposes. Their uninterrupted technical improvements, in terms of image resolution and capture frequency, in correspondence of a cost decrease, are enabling them to sport gesture study and athletic performance evaluation [1317]. Recent works in the literature described the application of ASC for two-dimensional (2D) analysis [1821]. Extending this technology for three-dimensional (3D) sport analysis using multiple cameras, however, still requires a methodologic step-forward to making ASC a metric system, encompassing ad-hoc camera setup, synchronization of the acquisitions, and devoted calibration protocols.

In swimming motion analysis for example, the camera setup is particularly demanding as the athletic gesture develops both in air and underwater concurrently. ASC manufacturers partially addressed this issue by developing different accessories, especially designed for underwater usage, as waterproof housings and support with suction cups to secure the cameras to the wall of the swimming pool. From an operational point of view, camera calibration represents a bottleneck to the development of video-based underwater motion analysis systems because of two main issues. First, the 3D reconstruction of the complete athletic gesture requires the calibration of both air and underwater cameras and a coordinate system registration in between them. At present time however, there are no standardized protocols available. Second, underwater calibration can require specific solutions addressing water disturbance of the image quality to ensure high reconstruction accuracy.

In order to achieve high accurate 3D underwater movement analysis, our group already addressed some critical points related mainly to underwater camera calibration. Using industrial cameras, we showed that the accuracy results of the wand-based and 2D plate-based calibration methods were less associated to the testing tool position in the working volume and provided better accuracy than the graduated rod-based calibration with nonlinear DLT [22]. The main advantage of using wand-based calibration was the equalization of the reconstruction error across the working volume, ensured by the bundle adjustment of the camera parameters. In contrast, 2D plate-based calibration led to an unregistered camera network as each camera was calibrated separately. However, 2D plate-based calibration was less sensitive to water quality than wand-based. In the [23], we applied wand-based underwater calibration to reconstruct with high accuracy the hand trajectory of four swimmers during front-crawl, breaststroke and butterfly styles.

In this paper, the underwater wand-based calibration procedure was applied to the ASC. Experimentally, two cameras were submerged into a swimming pool and located steady at the corners of a working volume of about 6m3. The measurement protocol encompassed calibration and testing acquisitions to compute camera parameters and evaluate the reconstruction accuracy, respectively, with two different image resolutions. The effect of a set of calibration data acquisition strategies, on the 3D accuracy, was investigated.

Materials and Methods

Instruments

The data acquisition was performed in a swimming pool. Two action sport cameras with waterproof housings (GoPro, Hero3+, Black Edition® / USA), were fixed on the wall of the swimming pool (see Fig 1). The view angle and acquisition frequency were 127° and 60Hz, respectively. Two different image resolutions were investigated, namely 1280×720 (LOWRES) and 1920×1080 (HIGHRES) pixels. In order to synchronize the cameras, we used the Wi-Fi remote GoPro control (see Fig 1B). After acquisition, the videos were converted to AVI movie format in the GoPro studio software.

thumbnail
Fig 1.

A) Calibration tools. B) Action sport cameras (GoPro, Hero3+, Black). C) Rigid bar used to 3D reconstruction accuracy evaluation. D) Camera position and acquisition volume.

https://doi.org/10.1371/journal.pone.0160490.g001

Camera calibration procedure

The wand-based calibration method consists in the acquisition of one static (a triad structure) and one moving (a wand structure) tool, carrying nine and one spherical passive markers, respectively. One waterproof orthogonal triad structure (1×1×1m) was built by a computer numerical control machine (CNC) screwing onto it nine spherical black markers (∅: 35 mm) in known positions (10μm accuracy). The triad was located at the floor of the swimming pool, in the center of the working volume (1×4×1.5m3) and acquired for 5 seconds (see Fig 1A). 2D marker segmentation in videos and centroid computation were performed using “Dvideo” software [24]. 2D data of triad markers were used to assess the initial intrinsic and extrinsic parameters of the cameras, using DLT method disregarding optical distortions [22], and define the origin and orientation of the working volume. In order to refine the camera parameters, also ensuring nonlinear optical distortion correction [25], a wand, carrying one spherical marker located at its extremity, was moved in the working volume, during about 20 seconds. “Dvideo” software was used again to track the marker in the image sequence of the two cameras. Four hundred useful video frames were used into a bundle adjustment nonlinear optimization, using control points with both known (triad markers) and unknown (wand marker) 3D coordinates [26]. The bundle adjustment iteratively estimates the parameters of all the cameras along with the unknown 3D marker coordinates by minimizing the 2D projection error (measured vs predicted by the camera model) on the images. The optical distortion was taken into account by adding one radial parameter into the camera model (Fig 2).

thumbnail
Fig 2. Schematic workflow of the two-stage camera calibration for a generic number of cameras.

https://doi.org/10.1371/journal.pone.0160490.g002

Calibration quality

The calibration quality was evaluated by the accuracy of 3D reconstruction in both image resolutions (HIGHRES and LOWRES). We used five acquisitions of the rigid bar, carrying two markers at known distance (dn: 250 mm), moved within the working volume during 15 seconds (Fig 1C). The wand was manufactured by CNC machine ensuring a marker positioning accuracy of about 10μm. In order to describe the 3D accuracy of ASC the following quantities were calculated for each trial: a) mean value of the marker distance; b) the standard deviation of the distance distribution; c) the mean absolute error (difference between the nominal and the measured marker distances); d) the percentage accuracy (the ratio between the absolute accuracy and the maximum diagonal of the working volume) [27]. The error distributions for HIGHRES and LOWRES were compared using a non-parametric test (Wilcoxon rank sum) with a significance of 1%. The calibration quality was also evaluated in laboratory and were compared to the underwater condition, using same camera setup (two cameras, HIGHRES and LOWRES, 60Hz, camera position) and calibration protocol (triad and wand tools).

Calibration dependability

Since the calibration quality can be affected by the performed wand acquisition movement [26], we evaluated the camera dependability testing three different acquisitions, namely zig-zag (M1), circular (M2) and up and down (M3). For this test, we used the high image resolution. As far as M1 is concerned, the operator was instructed to well cover all the camera field of view. In the M2 wand movement, the operator was instructed to perform circular movements within the working volume. In M3, the operator was instructed to move up-down the wand within the working volume. In addition, we evaluated whether to add an inter-marker distance constraint into the bundle adjustment (two-marker in the wand tool) could result in an improvement of the 3D reconstruction accuracy. Operatively, five different calibration tests (see Fig 3), explicitly M1-1 (one marker with zig-zig movement), M2-1 (one marker with circular movement), M3-1 (one marker with up-down), M1-2 (two markers with zig-zig movement) and M2-2 (two markers with circular movement), were performed. The quality of all the five calibrations was assessed again by reconstructing the distance between the markers of the test rigid bar moved within the working volume during about 20s.

thumbnail
Fig 3. Three different calibration wand movements to evaluate the calibration dependability.

https://doi.org/10.1371/journal.pone.0160490.g003

In order to analyze how the wand movement type and the number of markers affected the calibration dependability, we calculated the minimum, mean and maximum value of the distance between the markers, the standard deviation and the mean absolute error, in all the five acquisition protocols (M1-1, M2-1, M3-1, M1-2 and M2-2). The five distance error distributions were statistically analyzed by using a non-parametric test (Kruskal-Wallis) with a post-hoc (Tukey: p-value<0.05) (Matlab® 2012).

Results

Calibration quality

In the five repeated calibrations, the reconstruction error was below 2.6mm for both image resolutions. In Table 1, we listed mean of the distance between the markers, standard deviation and mean absolute errors (bias) of the five trials of the dynamic rigid bar test (2 markers).

thumbnail
Table 1. Results of the 5 trials of dynamic rigid bar test (HIGHRES and LOWRES).

Nominal distance dn between the two markers: 250mm.

https://doi.org/10.1371/journal.pone.0160490.t001

As expected, the bias of HIGHRES was lower (1.28mm) than that of LOWRES (2.41mm). The two error distributions were statistically (p-value<0.0001) different (see Fig 4). For comparison, the 3D reconstruction in laboratory using HIGHRES and LOWRES led to a mean absolute error of 1.56mm and 1.67mm, respectively.

thumbnail
Fig 4. The histograms of the residual error distribution (cumulated over the five trials) for HIGHRES (1920–1080) and LOWRES (1280–720).

The average values were 1.28 and 2.41mm, respectively.

https://doi.org/10.1371/journal.pone.0160490.g004

Calibration dependability

There was a significant difference (p<0.001) among the five different calibrations (Table 2). Since the movement M1 spread more the working volume, we found the best accuracy results in M1-1 (1.17 mm) and M1-2 (1.28 mm).

thumbnail
Table 2. Minimum, mean and maximum inter-marker distance, averaged across 5 trials and the corresponding mean absolute error (dn: 250mm).

M1-1 (one marker with zig-zig movement); M2-1 (one marker with circular movement); M3-1 (one marker with up-down); M1-2 (two markers with zig-zig movement); M2-2 (two markers with circular movement). The post-hoc comparison results were reported (*p<0.05).

https://doi.org/10.1371/journal.pone.0160490.t002

No significant difference was found when we compared M1 movement using or not the distance constraints (Table 2). When the movement did not spread systematically the working volume (M2), the usage of the distance constraint in the bundle calibration improved significantly the accuracy of results (M2-1 = 1.80mm, M2-2 = 1.47mm, p<0.001). M3-1 acquisition protocol (non-systematic movement and one marker wand) yielded the worst reconstruction error (2.63mm). As noticed, when considering M1-2 and M2-2 (different movements but with bar length constraint), no statistical difference was found.

Discussion

Performing 3D kinematic analysis in sports, as in the case of swimming, requires high reconstruction accuracy. The usage of nonlinear camera calibration was reported to improve the accuracy results found in laboratory conditions [25, 28, 29]. Reconstruction errors, ranging from 0.58 to about 1mm, were obtained when using optoelectronic systems and industrial cameras [15, 30, 23]. The reconstruction accuracy of ASC (wide-angle lenses—GoPro) was evaluated out of water conditions obtaining 10mm error in correspondence of a linear camera model [31]. In the same paper, the authors reported that the accuracy increased by five times (2mm) when adopting a nonlinear camera model. This last result is in agreement with our GoPro laboratory test (cfr. Table 1).

Underwater 3D analysis, based on cumbersome calibration structure and linear camera models, using traditional video-based systems, provided a reconstruction error higher than 5mm [3235]. In [22], it was shown that underwater camera calibration using industrial cameras and nonlinear camera model, improves on average the reconstruction accuracy up to 1mm across a working volume of about 7m3. This result was comparable with the values (2mm at 10m distance) reported by commercial systems devoted to 3D underwater analysis [12].

In the light of such prior results, the present study evaluated the reconstruction accuracy of underwater ASC calibrated using the wand method with a nonlinear camera model encompassing optical distortions [22]. We found that the average error upon the reconstructed inter-marker distances was less than 1.5mm (HIGHRES underwater and Land) on average across the whole working volume of about 6m3, comparable with the values reported in our previous work [22], with reconstruction errors reported in [36] using GoPro cameras and in [12] using the Oqus-Underwater system.

As far as the calibration dependability is concerned, the wand calibration movement, as expected, affected the reconstruction accuracy results. As shown (cfr. Table 2), spreading the wand systematically across the whole working volume (M1), led to the best accuracy results. The M3 protocol, featuring up-down wand movements without any systematic control, led in contrast to the poorest results. Circular movement (M2), while not systematically covering the entire working volume, ensured accuracy results less than 2mm, nonetheless worse than the results obtained with M1. The analysis of the calibration dependability related to the number of markers upon the calibration wand showed that one marker is sufficient when it is acquired well spread within the whole working volume. We point out that the use of two markers (distance constraint) can improve the reconstruction accuracy making the result less dependent on the wand movement performed by the operator (see Table 2: M1-2 vs M2-2). Based on these considerations, we can argue that the wand-based calibration makes ASC suitable competitive to industrial cameras for underwater motion analysis.

Some limits of the present study must be however discussed. First, we performed an evaluation of the potentiality of ASC in terms of calibration setup and reconstruction accuracy, disregarding the environmental issues relative to underwater conditions. For instance, the image contrast, which can be affected by the illumination of swimming pool, and the water disturbance, which is directly related to the speed of the swimmer, deteriorate the marker detection quality on the images (see Fig 5). Such environmental issues demand therefore specific testing to evaluate their effects on the 3D reconstruction accuracy. We plan to perform a systematic analysis of this effect in future works.

thumbnail
Fig 5. Two instants of the front-crawl swim cycle surveyed by two cameras.

The swimmer is equipped with surface markers attached to the right arm. This real condition elucidates how poor image contrast and water disturbance can complicate the automatic marker detection on the image and tracking analysis, affecting the accuracy of the 3D kinematic analysis.

https://doi.org/10.1371/journal.pone.0160490.g005

Second, the issue relative to the 3D kinematic analysis underwater is concerning the marker protocol utilized to compute the absolute and angular kinematics. While increasing the number of markers ensures a better body segment definition, marker labeling and tracking procedures complicate and the swimmer performance would be greater affected by water drag increase [37]. In order to avoid it, the use of crosses or circles drawn on the swimmer skin was proposed [38]. Alternatively, a complete markerless approach could be applied as described in [3940]. However, the segmentation of the complete swimmer silhouette on the images demand a complex network of camera with an enhanced underwater illumination to increase swimmer-to-water contrast [40].

Third, we did not perform an extensive evaluation of the role of the GoPro acquisition setup (image resolution, acquisition frequency and view angle of the camera). In this work, we aimed at studying the calibration accuracy for a typical size of the working volume ensuring at least one complete front crawl cycle. Arranging a 6m working volume wide and camera-to-working volume distance of about 3m required a camera view angle of about 130°. The only option from GoPro setup to cope with such demands was “medium”, featuring a view angle of 127°. With this camera setup we had available 24Hz, 30Hz, 48Hz and 60Hz frequencies. In order to cope with typical swimmer speed we choose 60Hz. A more systematic comparison among different setup, allowed by GoPro (resolution, view angle and acquisition frequency), will be the subject of future evaluations.

Fourth, we did not consider wearable technology for benchmark comparison. Especially, inertial-magnetic measurements units (IMMUs) have been recently proposed in the literature for underwater kinematic analysis [41]. While being in principle plug & play as they are wireless, these sensors can affect the swimmer performance due to the drag effect, which is augmented as the swimmer speed increases. It has to be pointed out that the drag causes for instance vibrations of the sensors, affecting the quality of the kinematic measure. In addition, to ensure underwater wireless data transmission, high capacity batteries are mandatory to cope with power consumption, increasing the size of the wearable devices.

Conclusions

This article was conceived to mainly demonstrate the feasibility of the quantitative 3D measurements underwater using action sport cameras. We showed that, by endowing action sport cameras with an opportune calibration methodology (handy tools and bundle adjustment), they can be made an accurate metric system. Compared to optoelectronic devices, especially designed for 3D motion analysis, this technology features low cost, reduced size, high portability, wireless facility and waterproof housings. Swimming, underwater gait, water aerobics, water polo are relevant potential applications for such an emerging technology.

Supporting Information

S1 Supporting Information.

S1.1_Calibration Quality > S1.1.1_Underwater > S1.1.1.1_Highres > S1.1.1.1.1_Calibration > File A. This is the BUNDLE_CameraParameters. This is the camera calibration parameters. File B. This is the Triad. This is the 2D coordinates of the waterproof orthogonal triad structure carrying nine spherical black markers. File C. This is the WandCalibration. This is the 2D coordinates of the wand structure carrying one spherical black marker. S1.1.1.1.2_Accuracy > File D. This is the Trial_1. This is the 2D coordinates of the first rigid bar test acquisition, carrying two markers at known distance. File E. This is the Trial_2. This is the 2D coordinates of the second rigid bar test acquisition, carrying two markers at known distance. File F. This is the Trial_3. This is the 2D coordinates of the third rigid bar test acquisition, carrying two markers at known distance. File G. This is the Trial_4. This is the 2D coordinates of the fourth rigid bar test acquisition, carrying two markers at known distance. File H. This is the Trial_5. This is the 2D coordinates of the fifth rigid bar test acquisition, carrying two markers at known distance. File I. This is the MotionSequence3D_Trial_1. This is the 3D coordinates of the first rigid bar test acquisition. File J. This is the MotionSequence3D_Trial_2. This is the 3D coordinates of the second rigid bar test acquisition. File K. This is the MotionSequence3D_Trial_3. This is the 3D coordinates of the third rigid bar test acquisition. File L. This is the MotionSequence3D_Trial_4. This is the 3D coordinates of the fourth rigid bar test acquisition. File M. This is the MotionSequence3D_Trial_5. This is the 3D coordinates of the fifth rigid bar test acquisition. S1.1.1.2_Lowres > S1.1.1.2.1_Calibration > File N. This is the BUNDLE_CameraParameters. This is the camera calibration parameters. File O. This is the Triad. This is the 2D coordinates of the waterproof orthogonal triad structure carrying nine spherical black markers. File P. This is the WandCalibration. This is the 2D coordinates of the wand structure carrying one spherical black marker. S1.1.1.2.2_Accuracy > File Q. This is the Trial_1. This is the 2D coordinates of the first rigid bar test acquisition, carrying two markers at known distance. File R. This is the Trial_2. This is the 2D coordinates of the second rigid bar test acquisition, carrying two markers at known distance. File S. This is the Trial_3. This is the 2D coordinates of the third rigid bar test acquisition, carrying two markers at known distance. File T. This is the Trial_4. This is the 2D coordinates of the fourth rigid bar test acquisition, carrying two markers at known distance. File U. This is the Trial_5. This is the 2D coordinates of the fifth rigid bar test acquisition, carrying two markers at known distance. File V. This is the MotionSequence3D_Trial_1. This is the 3D coordinates of the first rigid bar test acquisition. File W. This is the MotionSequence3D_Trial_2. This is the 3D coordinates of the second rigid bar test acquisition. File X. This is the MotionSequence3D_Trial_3. This is the 3D coordinates of the third rigid bar test acquisition. File Y. This is the MotionSequence3D_Trial_4. This is the 3D coordinates of the fourth rigid bar test acquisition. File Z. This is the MotionSequence3D_Trial_5. This is the 3D coordinates of the fifth rigid bar test acquisition. S1.1.2_Land > S1.1.2.1_Highres > S1.1.2.1.1_Calibration > File AA. This is the BUNDLE_CameraParameters. This is the camera calibration parameters. File AB. This is the Triad. This is the 2D coordinates of the waterproof orthogonal triad structure carrying nine spherical black markers. File AC. This is the WandCalibration. This is the 2D coordinates of the wand structure carrying one spherical black marker. S1.1.2.1.2_Accuracy > File AD. This is the Trial_Land. This is the 2D coordinates of the first rigid bar test acquisition, carrying two markers at known distance. File AE. This is the MotionSequence3D_Land. This is the 3D coordinates of the first rigid bar test acquisition, carrying two markers at known distance. S1.1.2.2_Lowres > S1.1.2.2.1_Calibration File AF. This is the BUNDLE_CameraParameters. This is the camera calibration parameters. File AG. This is the Triad. This is the 2D coordinates of the waterproof orthogonal triad structure carrying nine spherical black markers. File AH. This is the WandCalibration. This is the 2D coordinates of the wand structure carrying one spherical black marker. S1.1.2.2.2_Accuracy > File AI. This is the Trial_Land. This is the 2D coordinates of the first rigid bar test acquisitions, carrying two markers at known distance. File AJ. This is the MotionSequence3D_Land. This is the 3D coordinates of the first rigid bar test acquisitions. S1.2_Calibration Dependability > S1.2.1_Calibration > File AK. This is the BUNDLE_CameraParameters_Cal_Mov1_1p. This is the camera calibration parameters of the first movement (M1) with one marker. File AL. This is the BUNDLE_CameraParameters_Cal_Mov1_2p. This is the camera calibration parameters of the first movement (M1) with two markers. File AM. This is the BUNDLE_CameraParameters_Cal_Mov2_1p. This is the camera calibration parameters of the second movement (M2) with one marker. File AN. This is the BUNDLE_CameraParameters_Cal_Mov2_2p. This is the camera calibration parameters of the second movement (M2) with two markers. File AO. This is the BUNDLE_CameraParameters_Cal_Mov3_1p. This is the camera calibration parameters of the third movement (M3) with one marker. File AP. This is the Triad. This is the 2D coordinates of the waterproof orthogonal triad structure carrying nine spherical black markers. File AQ. This is the Cal_Mov1_1p. This is the 2D coordinates of the wand structure carrying one spherical black marker using the first movement (M1). File AR. This is the Cal_Mov1_2p. This is the 2D coordinates of the wand structure carrying two spherical black markers using the first movement (M1). File AS. This is the Cal_Mov2_1p. This is the 2D coordinates of the wand structure carrying one spherical black marker using the second movement (M2). File AT. This is the Cal_Mov2_2p. This is the 2D coordinates of the wand structure carrying two spherical black markers using the second movement (M2). File AU. This is the Cal_Mov3_1p. This is the 2D coordinates of the wand structure carrying one spherical black marker using the third movement (M3). S1.2.2_Accuracy > File AV. This is the Trial_1. This is the 2D coordinates of the first rigid bar test acquisition, carrying two markers at known distance. File AW. This is the Trial_2. This is the 2D coordinates of the second rigid bar test acquisition, carrying two markers at known distance. File AX. This is the Trial_3. This is the 2D coordinates of the third rigid bar test acquisition, carrying two markers at known distance. File AY. This is the Trial_4. This is the 2D coordinates of the fourth rigid bar test acquisition, carrying two markers at known distance. File AZ. This is the Trial_5. This is the 2D coordinates of the fifth rigid bar test acquisition, carrying two markers at known distance. S1.2.2.1_Mov1_1p > File BA. This is the MotionSequence3D_Trial_1. This is the 3D coordinates of the first rigid bar test acquisition. File BB. This is the MotionSequence3D_Trial_2. This is the 3D coordinates of the second rigid bar test acquisition. File BC. This is the MotionSequence3D_Trial_3. This is the 3D coordinates of the third rigid bar test acquisition. File BD. This is the MotionSequence3D_Trial_4. This is the 3D coordinates of the fourth rigid bar test acquisition. File BE. This is the MotionSequence3D_Trial_5. This is the 3D coordinates of the fifth rigid bar test acquisition. S1.2.2.2_Mov1_2p > File BF. This is the MotionSequence3D_Trial_1. This is the 3D coordinates of the first rigid bar test acquisition. File BG. This is the MotionSequence3D_Trial_2. This is the 3D coordinate of the second rigid bar test acquisition. File BH. This is the MotionSequence3D_Trial_3. This is the 3D coordinates of the third rigid bar test acquisition. File BI. This is the MotionSequence3D_Trial_4. This is the 3D coordinates of the fourth rigid bar test acquisition. File BJ. This is the MotionSequence3D_Trial_5. This is the 3D coordinates of the fifth rigid bar test acquisition. S1.2.2.3_Mov2_1p > File BK. This is the MotionSequence3D_Trial_1. This is the 3D coordinates of the first rigid bar test acquisition. File BL. This is the MotionSequence3D_Trial_2. This is the 3D coordinates of the second rigid bar test acquisition. File BM. This is the MotionSequence3D_Trial_3. This is the 3D coordinates of the third rigid bar test acquisition. File BN. This is the MotionSequence3D_Trial_4. This is the 3D coordinates of the fourth rigid bar test acquisition. File BO. This is the MotionSequence3D_Trial_5. This is the 3D coordinates of the fifth rigid bar test acquisition. S1.2.2.4_Mov2_2p > File BP. This is the MotionSequence3D_Trial_1. This is the 3D coordinates of the first rigid bar test acquisition. File BQ. This is the MotionSequence3D_Trial_2. This is the 3D coordinates of the second rigid bar test acquisition. File BR. This is the MotionSequence3D_Trial_3. This is the 3D coordinates of the third rigid bar test acquisition. File BS. This is the MotionSequence3D_Trial_4. This is the 3D coordinate of the fourth rigid bar test acquisition. File BT. This is the MotionSequence3D_Trial_5. This is the 3D coordinates of the fifth rigid bar test acquisition. S1.2.2.5_Mov3_1p > File BU. This is the MotionSequence3D_Trial_1. This is the 3D coordinates of the first rigid bar test acquisition. File BV. This is the MotionSequence3D_Trial_2. This is the 3D coordinates of the second rigid bar test acquisition. File BW. This is the MotionSequence3D_Trial_3. This is the 3D coordinates of the third rigid bar test acquisition. File BX. This is the MotionSequence3D_Trial_4. This is the 3D coordinates of the fourth rigid bar test acquisition. File BY. This is the MotionSequence3D_Trial_5. This is the 3D coordinates of the fifth rigid bar test acquisition.

https://doi.org/10.1371/journal.pone.0160490.s001

(ZIP)

Author Contributions

  1. Conceptualization: GRDB APS PC JCBM.
  2. Formal analysis: GRDB APS PC RMLB.
  3. Funding acquisition: APS RMLB.
  4. Investigation: GRDB APS.
  5. Methodology: GRDB APS PC RMLB JCBM.
  6. Project administration: APS.
  7. Resources: APS RMLB.
  8. Software: GRDB APS PC RMLB.
  9. Supervision: APS.
  10. Visualization: APS PC.
  11. Writing - original draft: GRDB APS.
  12. Writing - review & editing: GRDB APS PC RMLB JCBM.

References

  1. 1. Olsen E, Andersen PH, Pfau T. Accuracy and Precision of Equine Gait Event Detection during Walking with Limb and Trunk Mounted Inertial Sensors. Sensors. 2012; 12(6): 8145–8156. pmid:22969392
  2. 2. Safayi S, Jeffery ND, Shivapour SK, Zamanighomi M, Zylstra TJ, Bratsch-Prince J, et al. Kinematic analysis of the gait of adult sheep during treadmill locomotion: Parameter values, allowable total error, and potential for use in evaluating spinal cord injury. J Neurol Sci. 2015; 358: 107–112. pmid:26341152
  3. 3. Sinclair J, Richards J, Taylor PJ, Edmundson CJ, Brooks D, Hobbs SJ. Three-dimensional kinematic comparison of treadmill and overground running. Sport Biomech. 2013; 12(3): 272–282.
  4. 4. Bates NA, Ford KR, Myer GD, Hewett TE. Impact differences in ground reaction force and center of mass between the first and second landing phases of a drop vertical jump and their implications for injury risk assessment. J Biomech. 2013; 46(7):1237–1241. pmid:23538000
  5. 5. Joyce C, Burnett A, Cochrane J, Ball K. Three-dimensional trunk kinematics in golf: between-club differences and relationships to clubhead speed. Sport Biomech. 2013; 12(2): 108–120.
  6. 6. Seminati E, Marzari A, Vacondio O, Minetti AE. Shoulder 3D range of motion and humerus rotation in two volleyball spike techniques: injury prevention and performance. Sport Biomech. 2015; 14(2):216–231.
  7. 7. Begon M, Leardini A, Belvedere C, Farahpourc N, Allard P. Effects of front a land sagittal thorax attitudes in gait on trunk and pelvis three-dimensional kinematics. Med Eng Phys. 2015; 37(10):1032–6. pmid:26337553
  8. 8. Klotz MCM, Kost L, Braatz F, Ewerbeck V, Heitzmann D, Gantz S, et al. Motion capture of the upper extremity during activities of daily living in patients with spastic hemiplegic cerebral palsy. Gait Posture. 2013; 38(1):148–152. pmid:23218727
  9. 9. Maier MW, Niklasch M, Dreher T, Zeifang F, Rettig O, Klotz MC, et al. Motion patterns in activities of daily living: 3- year longitudinal follow-up after total shoulder arthroplasty using an optical 3D motion analysis system. BMC Musculoskelet Disord. 2014; 15(244).
  10. 10. Gefen A, Megido-Ravid M, Itzchak Y, Arcan M. Biomechanical Analysis of the Three-Dimensional Foot Structure During Gait: A Basic Tool for Clinical Applications. J Biomech Eng. 2000; 122(6): 630–639. pmid:11192385
  11. 11. Wahid F, Begg R, McClelland JA, Webster KE, Halgamuge S, Ackland DC. A multiple regression normalization approach to evaluation of gait in total knee arthroplasty patients. Clin Biomech. 2016; 32:92–101.
  12. 12. Qualysis Oqus Underwater. 2014. Available: http://www.qualisys.com/wp-content/uploads/2014/01/PI_Oqus_Underwater.pdf
  13. 13. Chong AK. Low-cost compact cameras: a medical application in CMT disease monitoring. Photogramm Rec. 2011; 26(134): 263–273.
  14. 14. Silvatti AP, Sarro KJ, Cerveri P, Baroni G, Barros RML. A 3D kinematic analysis of breathing patterns in competitive swimmers. J Sports Sci. 2012; 30(14): 1551–1560. pmid:22897476
  15. 15. Bernardina, GRD., Silva, RG, Cerveri, P., Barros RML and Silvatti AP, Accuracy of sport action cameras for 3d underwater motion analysis. Proceedings of the 32 International Conference of Biomechanics in Sports 2014. pp. 505–508 ISSN 1999-4168.
  16. 16. Monnet T, Samson M, Bernard A, David L, Lacouture P. Measurement of three-dimensional hand kinematics during swimming with a motion capture system: a feasibility study. Sports Eng. 2014; 17(3): 171–181.
  17. 17. Fujii K, Shinya M, Yamashita D, Kouzaki M, Oda S. Anticipation by basketball defenders: An explanation based on the three-dimensional inverted pendulum model. Eur J Sport Sci. 2014; 14(6): 538–546. pmid:24397711
  18. 18. García-Ramos A, Feriche B, de la Fuente B, Argüelles-Cienfuegos J, Strojnik V, Strumbelj B, et al. Relationship between different push-off variables and start performance in experienced swimmers. Eur J Sport Sci. 2015; 15(8): 687–695. pmid:26305175
  19. 19. McDonnell L, Hume P, Nolte V. Sprint kayaking stroke rate reliability, variability and validity of the Digitrainer accelerometer compared to GoPro video measurement. In Proceedings of the XXX International Symposium on Biomechanics in Sports, Melbourne, Australia. 2012. pp. 316–319. ISSN 1999-4168.
  20. 20. Timmis MA, Turner K, van Paridon KN. Visual Search Strategies of Soccer Players Executing a Power vs. Placement Penalty Kick. PLoS ONE. 2014; 9(12): 115–179.
  21. 21. Vieira LHP, Pagnoca EA, Milioni F, Barbieri RA, Menezes RP, Alvarez L, et al. Tracking futsal players with a wide-angle lens camera: accuracy analysis of the radial distortion correction based on an improved Hough transform algorithm. Comput Methods Biomech Biomed Eng Imaging Vis. 2015.
  22. 22. Silvatti AP, Dias FAS, Cerveri P, Barros RML. Comparison of different camera calibration approaches for underwater applications. J Biomech. 2012; 45(6): 1112–1116. pmid:22284990
  23. 23. Silvatti AP, Cerveri P, Telles T, Dias FAZ, Baroni G, Barros RML. Quantitative underwater 3D motion analysis using submerged video cameras: accuracy analysis and trajectory reconstruction. Comput Methods Biomech Biomed Eng. 2013; 16(11): 1240–1248.
  24. 24. Figueroa PJ, Leite NJ, Barros RML. A flexible software for tracking of markers used in human motion analysis. Comput Methods Programs Biomed. 2003; 72(2): 155–165. pmid:12941519
  25. 25. Cerveri P, Borghese NA, Pedotti A. Complete calibration of a stereo photogrammetric system through control points of unknown coordinates. J Biomech. 1998; 31(10): 935–940. pmid:9840759
  26. 26. Cerveri P, Pedotti A, Borghese NA. Combined evolution strategies for dynamic calibration of video-based measurement systems. IEEE Trans Evolut Comput. 2001; 5(3): 271–282.
  27. 27. Chiari L, Della Croce U, Leardini A, Cappozzo A., Human movement analysis using stereophotogrammetry. Part 2: instrumental errors. Gait Posture. 2005, 21(2):197–211. pmid:15639399
  28. 28. Zhang Z. A flexible new technique for camera calibration. IEEE Trans Pattern Anal. 2000; 22(11): 1330–1334.
  29. 29. Wang J, Shi F, Zhang J, Liu Y. A new calibration model of camera lens distortion. Pattern Recognit. 2008; 41(2): 607–615.
  30. 30. Pribanić T, Sturm P, Cifrek M. Calibration of 3D kinematic systems using 2D calibration plate. In Proceedings of the XXVI International Symposium on Biomechanics in Sports, Seoul, Korea. 2008. pp. 77–80. ISSN 1999-4168.
  31. 31. Balletti C, Guerra F, Tsioukas V, Vernier P. Calibration of action cameras for photogrammetric purposes. Sensors. 2014; 14(9): 17471–17490. pmid:25237898
  32. 32. Yanai T, Hay JG, Gerot JT. Three-dimensional videography of swimming with panning periscopes. J Biomech. 1996; 29(5): 673–678. pmid:8707797
  33. 33. Kwon YH, Lindley SL. Applicability of four localized-calibration methods in underwater motion analysis. In Proceedings of the XVIII International Symposium on Biomechanics in Sports, Hong Kong, China. 2000. pp. 48–55. ISSN 1999-4168.
  34. 34. Gourgoulis V, Aggeloussis N, Kasimatis P, Vezos N, Boli A, Mavromatis G. Reconstruction accuracy in underwater three-dimensional kinematic analysis. J Sci Med Sport. 2008; 11(2): 90–95. pmid:17544326
  35. 35. Jesus K, Jesus K, Figueiredo P, Vilas-Boas JP, Fernandes RJ, Machado LJ. Reconstruction accuracy assessment of surface and underwater 3D motion analysis: a new approach. Comput Math Methods Med. 2015. Article ID 269264.
  36. 36. Shortis M. Calibration Techniques for accurate measurements by underwater camera systems. Sensors 2015, 15(12), 30810–30826; pmid:26690172
  37. 37. Magalhaes FA, Sawacha Z, Di Michele R, Cortesi M, Gatta G, Fantozzi S., Effectiveness of an automatic tracking software in underwater motion analysis. J Sports Sci Med. 2013; 12(4):660–7. pmid:24421725
  38. 38. Ceccon S, Ceseracciu E, Sawacha Z, Gatta G, Cortesi M, Cobelli C, Fantozzi S. Motion analysis of front crawl swimming applying CAST technique by means of automatic tracking. J Sports Sci., 2013; 31(3) 276–287. pmid:23057667
  39. 39. Ceseracciu E, Sawacha Z, Fantozzi S, Cortesi M, Gatta G, Corazza S, et al. Markerless analysis of front crawl swimming. J Biomech. 2011; 44(12): 2236–2242. pmid:21719017
  40. 40. Ceseracciu E, Sawacha Z, Cobelli C. Comparison of markerless and marker-based motion capture technologies through simultaneous data collection during gait: proof of concept. PLoS ONE. 2014; 9(3): e87640. pmid:24595273
  41. 41. Fantozzi S, Giovanardi A, Borra D, Gatta G. Gait kinematic analysis in water using wearable inertial magnetic sensors. PLos ONE. 2015; 10(9): e0138105. pmid:26368131