Developing Repair Materials for Stress Urinary Incontinence to Withstand Dynamic Distension
Fig 7
Values for Mechanical properties before and after 7 days of dynamic loading.
Young’s Modulus (top) and ultimate tensile strength (bottom) calculated from stress curves before and after 7 days of uniaxial distension (n-2±SEM), *p<0.05, **p<0.01, ***p<0.001. Dotted lines represent values of healthy paravaginal tissues [24].