Abstract
The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) from rainwater by solid-phase extraction (SPE) with three different types of cartridge, and analysis by high-performance liquid chromatography with fluorescence detection, are discussed in this paper. Three cartridges were investigated but only one was suitable. After equilibration in a desiccator for 65–80 h or in ambient air for 90–100 h the SPE cartridges were activated with 5 mL dichloromethane then 5 mL 2-propanol. The volume of sample passed through the cartridges was 50 mL; after loading of the sample the cartridges were dried under vacuum for approximately 20 min by application of a pressure of 15 mbar to the SPE manifold. The PAHs were eluted with 5 mL dichloromethane–hexane, 50:50 (v/v). The flow rate used for conditioning, sample loading, and elution was 2.5 mL min−1, achieved by application of a pressure of 6 mbar. For analysis of PAHs in rainwater, recovery was between 67 and 99%, the relative standard deviation varied between 2 and 5%, and the detection limits of the method were less than 16.9 ng L−1 for several PAHs. These optimum conditions were used for analysis of rainwater collected between June 2002 and May 2003 at two sites in Alsace (eastern France) and 17 PAHs were quantitatively determined. Concentrations varied between 1.6 and 968.1 ng L−1.
Similar content being viewed by others
References
IARC (1983) Polynuclear aromatic compounds, Part 1. Chemicals, environment and experimental data. IARC monographs on the evaluation of the carcinogenic risk of chemicals to humans, 32. IARC, Lyon
US Environmental Protection Agency (2000) Guidelines establishing test procedures for the analysis of pollutants. Federal register, 49, 209, USEPA, Washington, DC
Manoli E, Samara C (1999) Trends Anal Chem 18:417–428
Martinez E, Gros M, Lacorte S, Barcelo D (2004) J Chromatogr A 1047:181–188
Geffard O, Geffard A, His E, Budzinski H (2003) Mar Pollut Bull 46:481–490
Peltonen K, Kuljukka T (1995) J Chromatogr A 710:93–108
Thurman EM, Mills MS (1998) Solid-Phase Extraction: Principles and Practice. John Wiley and Sons Inc., New York, 372 pp
Kiss G, Varga-Puchony Z, Hlavay J (1996) J Chromatogr A 725:261–272
Marc RM, Borrull F (2000) J Chromatogr A 885:273–290
Sargenti SR, McNair HM (1998) J Microcolumn Sep 10:125–131
Oleszczuk P, Baran S (2004) J Hazard Mater B 113:237–245
Kicinski HG, Adamek S, Kettrup A (1989) Chromatographia 28:203–208
Gomma EA, Gray JI, Rabie S, Bote CL, Boorem AM (1993) Food Addit Contam 10:503–510
Popp P, Bauer C, Moder M, Paschke A (2000) J Chromatogr A 897:153–159
Liska I, Kuthan A, Krupcik J (1990) J Chromatogr A 509:123–134
Rostad CE, Pereira WE, Ratcliff SM (1984) Anal Chem 56:2857–2863
Junk GA, Avery MJ, Richard JJ (1988) Anal Chem 60:1347–1350
Chladek E, Marano S (1984) J Chromatogr Sci 22:313–320
Waters Oasis Cartridges, care and use manual. Millipore, Milford, MA
Meng-Xia X, Xie F, Deng Z, Zhuang G (2003) Talanta 60:1245–1257
Lohmann R, Northcott GL, Jones KC (2000) Environ Sci Technol 34:2892–2899
Ollivon D, Blanchoud H, Motelay-Massei A, Garban B (2002) Atmos Environ 36:2891–2900
Fernandez P, Carrera G, Grimalt JO, Ventura M, Camarero L, Catalan J, Nickus U, Thies H, Psenner R (2003) Environ Sci Technol 37:3261–3267
Motelay-Massei A, Ollivon D, Garban B, Chevreuil M (2003) Atmos Environ 37:3135–3146
Leoz-Garziandia E (2000) Report no. DRC/AIRE-00 23 448-Ele-no. 570, Ineris
Acknowledgments
The authors want to thank the “Région Alsace” and “DRIRE Alsace” for financial support.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Delhomme, O., Rieb, E. & Millet, M. Solid-Phase Extraction and LC with Fluorescence Detection for Analysis of PAHs in Rainwater. Chroma 65, 163–171 (2007). https://doi.org/10.1365/s10337-006-0144-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1365/s10337-006-0144-z