Advances in prostate cancer imaging

[version 1; peer review: 3 approved]
PUBLISHED 24 Aug 2018
Author details Author details
OPEN PEER REVIEW
REVIEWER STATUS

Abstract

Many exciting advances in medical imaging have been made in recent years that will alter the way we diagnose, stage, and treat patients with prostate cancer. Multiparametric magnetic resonance imaging (MRI) is emerging as the main modality for prostate cancer imaging. Contrast-enhanced ultrasound and shear wave elastography may be strong alternatives in patients who cannot undergo MRI. Prostate-specific membrane antigen-directed positron emission tomography/computed tomography has proven to be valuable in the primary staging of high-risk disease and for detecting disease in patients with biochemical recurrence. As more studies continue to emerge, it is becoming clear that the standard algorithm for diagnosing and staging prostate cancer will undergo significant changes in the near future.

Keywords

Multiparametric MRI, PSMA-PET/CT, Ultrasound elastography, Prostate cancer

Introduction

Over the past several years, many advances have been made in the field of advanced imaging in the diagnosis of prostate cancer that will likely have strong sustained effects. The results of recent studies, such as those of the prostate magnetic resonance imaging (MRI) study (PROMIS), are already being applied in clinical practice. Multiparametric MRI (mpMRI) is one example of an imaging modality that has recently been implemented to aid the diagnosis and treatment of prostate cancer. Additional encouraging innovations include the use of contrast-enhanced ultrasound, ultrasound elastography, and prostate-specific membrane antigen-directed positron emission tomography (PSMA-PET). In particular, PSMA-PET shows much promise for the identification of local tumor recurrence in patients with a rising prostate-specific antigen (PSA) status post radical prostatectomy in whom conventional imaging would otherwise be of limited sensitivity. The objective of this article is to give a brief review on upcoming advances in prostate cancer imaging and provide an overview of what may be more widely available for clinical practice in the near future.

Prostate magnetic resonance imaging

Currently, men who are identified to be at risk of prostate cancer undergo a transrectal ultrasound (TRUS)-guided biopsy. Unfortunately, it is known that TRUS has limited sensitivity and specificity for the detection of prostate cancer1. Therefore, biopsies taken via this method are done somewhat “blindly” throughout the prostate, which can result in a high false-negative rate, misrepresentation of the true tumor burden, and the potential for complications including urinary tract infection, Gram-negative bacteremia, dysuria, and pain/discomfort24. In contrast, most other solid organ cancers are first identified by imaging and then image-guided biopsies are obtained to increase the yield. PROMIS sought to utilize imaging alone via mpMRI in all men with suspected prostate cancer to bring the screening of prostate cancer up to the current standards of other organ systems. It found that the sensitivity of mpMRI for clinically significant cancer is around 93%, with a negative predictive value of 89%. The specificity was 41% with a positive predictive value of 51%, meaning mpMRI is more sensitive than TRUS-guided biopsy (93% versus 48%), but TRUS-guided biopsy had better specificity (41% versus 96%)5. PROMIS suggests that if mpMRI were used as a triage test, approximately one in four men may be able to safely avoid prostate biopsy owing to its high negative predictive value (89% for mpMRI and 74% for TRUS). The limitation of mpMRI is its low specificity, meaning that an image-guided biopsy would still be required in men with suspicious mpMRI findings5. However, this may be subject to change in the future with the advent of more modern technology and newer methods of prostate imaging. For example, PROMIS used T1W, T2W, DWI, and dynamic gadolinium-enhanced imaging with a 1.5 Tesla scanner and pelvic phase array. Currently, 3 Tesla scanners are becoming more commonplace, and endorectal coils are now used to increase the signal-to-noise ratio and thus image quality; both demonstrate potential to increase sensitivity for the detection of prostate cancer6,7. One recent study that included these technologies has already demonstrated that MRI before biopsy and MRI-targeted biopsy is superior to TRUS-guided biopsy in biopsy-naïve men deemed at risk for prostate cancer8.

One alternative to mpMRI as a triage test is to perform mpMRI in patients who underwent a negative prostate biopsy and had some indication for repeat biopsy or who tested positive and required reclassification. The prostate imaging compared to transperineal ultrasound-guided biopsy for significant prostate cancer risk evaluation (PICTURE) trial sought to use mpMRI as a means of risk stratifying men with a negative TRUS-guided biopsy to determine whether a repeat TRUS-guided biopsy would be necessary or mpMRI could be obtained instead. The results demonstrate that in men who may require repeat biopsies, mpMRI can safely rule out clinically significant prostate cancer because of its high sensitivity and negative predictive value. Specifically, men with low-risk findings on mpMRI have a 10% chance of clinically significant cancer9. Initially, widespread mpMRI use was not believed to be feasible owing to concerns over cost-effective care10. However, recent studies indicate that mpMRI is a viable approach for the early detection of prostate cancer from a cost-effectiveness perspective not only in biopsy-naïve patients but also in patients with previous negative biopsies as well11. Nonetheless, mpMRI will likely be used in the future for risk stratifying patients who would have otherwise undergone repeat TRUS-guided biopsies.

Multiparametric ultrasound

Historically, TRUS-guided biopsy was and continues to be used for detecting suspected sites of neoplastic proliferation as well as local staging12. The standard technique that is utilized is grayscale ultrasonography. As alluded to above, grayscale is not accurate at identifying a large percentage of prostate cancers. Approximately 50% of prostate cancers appear hypoechoic, but as many as 30% are isoechoic to the surrounding normal tissue and thus not easily identifiable13. In addition, only one-third of hypoechoic lesions end up being prostate cancer, rendering only about 40% of prostate cancers detectable on grayscale ultrasonography13,14. In an attempt to circumvent the shortcomings of standard grayscale imaging, multiple other ultrasound techniques have been applied.

Color and power Doppler ultrasound may play some role in detecting prostate cancer. The general principle is that prostate cancer requires angiogenesis in order to develop into clinically significant disease15. Both color and power Doppler can help identify hyperemic tissue and therefore potential prostate cancer. Power Doppler is more sensitive than color Doppler, but neither of them is sensitive enough to detect early stage prostate cancers. The limited resolution results in the detection of vessels in the millimeter range, whereas angiogenesis can result in vessels as small as 10–50 micrometers15. Therefore, the utility of color and power Doppler ultrasonography may be restricted to detecting only higher Gleason grade tumors16.

Contrast-enhanced ultrasound (CEUS) is a relatively new technique that is not frequently used in the United States in the clinical setting. It involves the intravenous injection of gas-filled microbubbles that are comparable to the size of erythrocytes just prior to or during ultrasound image acquisition17. The injected microbubbles enhance the backscatter of ultrasound waves, resulting in the amplification of signals from blood flow. The ultrasound transducer recognizes these regions and creates images from both the nonlinear oscillation of microbubbles and the microbubble destruction18. Prostate cancer, even in its early stages, generally has increased flow due to angiogenesis and on CEUS will demonstrate asymmetric rapid inflow, increased focal enhancement, and asymmetry of intraprostatic vessels that are beyond the resolution of conventional techniques including color and power Doppler19. An algorithm is used to calculate a peak intensity value, which corresponds to the degree of enhancement; one study concluded that this can help differentiate between benign and malignant lesions20.

One other promising area in the field of sonography is the use of ultrasound elastography, more specifically shear wave elastography (SWE). SWE is currently being utilized for staging chronic liver disease and has numerous other potential beneficial applications as well21. SWE, in contrast to strain elastography (SE), is dependent solely on Young’s modulus and the pulse transmitted by the ultrasound transducer; therefore, there is less variability compared to SE, which relies on transducer compression, resulting in significant interobserver variability22. The stiffness of prostate cancer relative to normal prostatic tissue is known, and using SWE can help distinguish neoplastic lesions23. A recent systematic review of SWE alluded to sensitivity and specificity values comparable to those seen in mpMRI24. This implies that SWE may be appropriate independently for elucidating targets during ultrasound-guided biopsies.

Prostate-specific membrane antigen-directed positron emission tomography/computed tomography

PSMA is expressed on the cell surface of normal prostate tissue and is overexpressed in prostate cancer by several orders of magnitude. Therefore, this antigen was used as a target for prostate cancer-specific imaging25. Initially, PSMA was tagged with Indium 111, but the lack of internalization by viable prostate epithelial cells led to limited use in diagnosing tumors within the prostate gland and seminal vesicles26. 68Gallium-labeled PSMA, on the other hand, demonstrates high tumor-to-background contrast and is a small molecule, which aids in internalization and the detection of primary prostate tumors27. The highest perceived benefit of 68Gallium-PSMA ligand PET/CT is in the primary staging of high-risk disease and for detecting disease in patients with biochemical recurrence. Preliminary data also show that 68Gallium-PSMA ligand PET/CT may be beneficial for biopsy targeting after a previous negative biopsy in a patient highly suspected of having prostate cancer, especially when combined with mpMRI28. Currently, a multicenter prospective randomized controlled trial is taking place in Australia that aims to compare the diagnostic accuracy of PSMA-PET/CT to conventional imaging in detecting nodal and distant metastatic disease29. One study has already shown that PSMA-PET may be complementary to stand-alone mpMRI for tumor localization (sensitivity of PET 64%, mpMRI 58%, and 68Ga-PSMA-PET/MRI 76%)30. The National Comprehensive Cancer Network (NCCN) states that PET/CT can be considered in patients with PSA persistence/recurrence status post radical prostatectomy utilizing both C-11 choline or F-18 fluciclovine, a relatively new addition31.

Conclusion

Emerging technology is changing how we approach the diagnosis of prostate cancer from an imaging standpoint. mpMRI continues to demonstrate utility in risk stratifying patients with suspected prostate cancer and will be the foundation for prostate cancer imaging in the future. SWE may independently be used to identify suspected cancer during TRUS-guided biopsies. The emergence of PET in the diagnostic work-up of prostate cancer, specifically PSMA-PET, shows promise in the detection of recurrence in patients where conventional imaging (whole body bone scan, CT) may be negative. Overall, new imaging technology will allow for more accurate diagnosis, staging, and treatment follow-up in patients with prostate cancer in the near future.

Comments on this article Comments (0)

Version 1
VERSION 1 PUBLISHED 24 Aug 2018
Comment
Author details Author details
Competing interests
Grant information
Copyright
Download
 
Export To
metrics
Views Downloads
F1000Research - -
PubMed Central
Data from PMC are received and updated monthly.
- -
Citations
CITE
how to cite this article
Tangel MR and Rastinehad AR. Advances in prostate cancer imaging [version 1; peer review: 3 approved] F1000Research 2018, 7(F1000 Faculty Rev):1337 (https://doi.org/10.12688/f1000research.14498.1)
NOTE: it is important to ensure the information in square brackets after the title is included in all citations of this article.
track
receive updates on this article
Track an article to receive email alerts on any updates to this article.

Open Peer Review

Current Reviewer Status: ?
Key to Reviewer Statuses VIEW
ApprovedThe paper is scientifically sound in its current form and only minor, if any, improvements are suggested
Approved with reservations A number of small changes, sometimes more significant revisions are required to address specific details and improve the papers academic merit.
Not approvedFundamental flaws in the paper seriously undermine the findings and conclusions
Version 1
VERSION 1
PUBLISHED 24 Aug 2018
Views
0
Cite
Reviewer Report 24 Aug 2018
Friedrich Aigner, Department of Radiology, Medical University Innsbruck, Innsbruck, Austria 
Approved
VIEWS 0
I confirm that I have read this submission and believe that I have an ... Continue reading
CITE
CITE
HOW TO CITE THIS REPORT
Aigner F. Reviewer Report For: Advances in prostate cancer imaging [version 1; peer review: 3 approved]. F1000Research 2018, 7(F1000 Faculty Rev):1337 (https://doi.org/10.5256/f1000research.15783.r36963)
NOTE: it is important to ensure the information in square brackets after the title is included in all citations of this article.
Views
0
Cite
Reviewer Report 24 Aug 2018
Stefano Fanti, Nuclear Medicine Unit, S.Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy 
Approved
VIEWS 0
I confirm that I have read this submission and believe that I have an ... Continue reading
CITE
CITE
HOW TO CITE THIS REPORT
Fanti S. Reviewer Report For: Advances in prostate cancer imaging [version 1; peer review: 3 approved]. F1000Research 2018, 7(F1000 Faculty Rev):1337 (https://doi.org/10.5256/f1000research.15783.r36962)
NOTE: it is important to ensure the information in square brackets after the title is included in all citations of this article.
Views
0
Cite
Reviewer Report 24 Aug 2018
Geert Villeirs, Department of Radiology, Ghent University Hospital, Ghent, Belgium 
Approved
VIEWS 0
I confirm that I have read this submission and believe that I have an ... Continue reading
CITE
CITE
HOW TO CITE THIS REPORT
Villeirs G. Reviewer Report For: Advances in prostate cancer imaging [version 1; peer review: 3 approved]. F1000Research 2018, 7(F1000 Faculty Rev):1337 (https://doi.org/10.5256/f1000research.15783.r36961)
NOTE: it is important to ensure the information in square brackets after the title is included in all citations of this article.

Comments on this article Comments (0)

Version 1
VERSION 1 PUBLISHED 24 Aug 2018
Comment
Alongside their report, reviewers assign a status to the article:
Approved - the paper is scientifically sound in its current form and only minor, if any, improvements are suggested
Approved with reservations - A number of small changes, sometimes more significant revisions are required to address specific details and improve the papers academic merit.
Not approved - fundamental flaws in the paper seriously undermine the findings and conclusions
Sign In
If you've forgotten your password, please enter your email address below and we'll send you instructions on how to reset your password.

The email address should be the one you originally registered with F1000.

Email address not valid, please try again

You registered with F1000 via Google, so we cannot reset your password.

To sign in, please click here.

If you still need help with your Google account password, please click here.

You registered with F1000 via Facebook, so we cannot reset your password.

To sign in, please click here.

If you still need help with your Facebook account password, please click here.

Code not correct, please try again
Email us for further assistance.
Server error, please try again.