陈乐, 高文科, 冀宏, 张磊. 基于HP滤波与ARIMA-GARCH模型的柱塞泵泄漏量预测[J]. 农业工程学报, 2022, 38(10): 61-67. DOI: 10.11975/j.issn.1002-6819.2022.10.008
    引用本文: 陈乐, 高文科, 冀宏, 张磊. 基于HP滤波与ARIMA-GARCH模型的柱塞泵泄漏量预测[J]. 农业工程学报, 2022, 38(10): 61-67. DOI: 10.11975/j.issn.1002-6819.2022.10.008
    Chen Le, Gao Wenke, Ji Hong, Zhang Lei. Predicting leakage in a piston pump using HP filter and ARIMA-GARCH model[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2022, 38(10): 61-67. DOI: 10.11975/j.issn.1002-6819.2022.10.008
    Citation: Chen Le, Gao Wenke, Ji Hong, Zhang Lei. Predicting leakage in a piston pump using HP filter and ARIMA-GARCH model[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2022, 38(10): 61-67. DOI: 10.11975/j.issn.1002-6819.2022.10.008

    基于HP滤波与ARIMA-GARCH模型的柱塞泵泄漏量预测

    Predicting leakage in a piston pump using HP filter and ARIMA-GARCH model

    • 摘要: 柱塞泵关键摩擦副磨损造成的泄漏增大是其性能退化的主要原因,预测泄漏量的变化趋势有助于定量分析柱塞泵性能退化过程。该研究使用HP(Hodrick-Proscott)滤波对柱塞泵泄漏量进行分解,结合滤波后得到的趋势数据具有非线性及方差异性的特征,基于时间序列方法建立HP-ARIMA-GARCH(HP-Auto Regressive Integrated Moving Average- Generalized Autoregressive Conditionally Heteroscedastic)模型预测柱塞泵泄漏量变化。通过不同时段泄漏量预测结果比较可知,根据HP滤波分解后得到的趋势数据序列建立的HP-ARIMA-GARCH模型较传统时间序列模型预测结果的平均相对误差最高可减小5.42个百分点,能够实现对泄漏量的有效预测。研究结论可为柱塞泵性能退化的定量预测提供理论参考。

       

      Abstract: Abstract: A piston pump has been widely used in large agricultural equipment, and walking machinery. However, the leakage can often be induced by the performance degradation with the increase of cumulative running time, even threat to the volumetric efficiency and operation safety of the equipment. It is a high demand for the accurate and rapid prediction of the performance degradation state in the piston pump for better working reliability. In this study, the leakage was selected as the characteristic indicator to quantitatively analyze the performance degradation of the piston pump. A Hodrick-Proscott (HP) filtering was first utilized to divide the leakage volume of the piston pump into the long-term trend data and short-term fluctuation data in the modeling. A correlation function graph of long-term trend term data was drawn to observe the effective lag order, and then the Akaike information criterion (AIC) criterion was used to select the optimal order. The autoregressive integrated moving average model (ARIMA(16, 3, 0)) was established to verify the data characteristics of the residual sequence using the statistical analysis. After that, a generalized autoregressive conditional heteroscedasticity (GARCH (1,1)) model was established to combine with the data characteristics of nonlinear and heteroscedasticity of long-term trend data. As such, an HP-ARIMA-GARCH model was established for the trend item data to predict the leakage of the piston pump. The residual sequence was approximately normal distribution after testing, fully meeting the requirements of the model. The leakage prediction was performed on the same pump in different time periods and different pumps in the same time period. The accuracy of the proposed model was then determined to compare with the linear ARIMA model and the nonlinear self-excitable threshold autoregression (SETAR) model. The mean absolute error (MAE), mean square error (MSE), and the mean relative error (MRE) of the HP-ARIMA model were significantly reduced in all prediction periods, compared with the traditional ARIMA model, where the maximum average relative error was 2.42%. Therefore, it infers that the HP filtering can be widely expected to effectively extract the long-term trend of leakage data, and then filter out the noise interference for the lower prediction error of the time series model. Furthermore, there was a relatively smaller error in the nonlinear time series model for the higher prediction accuracy, compared with the traditional linear model. Nevertheless, there was a varying prediction of the improved model in the prediction accuracy. The reason was the inconsistent leakage of the piston pumps during the different periods and the rapid fluctuation in the short time during operation. More importantly, the error of unfiltered data was less than that of the filtered, indicating that the nonlinear model performed better than the linear one. The highest prediction accuracy was achieved in the HP-ARIMA-GARCH model, where the average relative error was within 1.5%. Therefore, the improved time series model was more accurate than before, particularly suitable for the leakage prediction of the piston pump. Above all, the finding can provide a theoretical reference to quantitatively predict the performance degradation of piston pump, especially for the decision-making on the equipment reliability and operational safety. The long-term prediction accuracy can be further improved in the time series model in the future. Besides, the fluctuation data by the HP filter can also be expected for the higher prediction accuracy of leakage, considering the valuable information of the time series model, rather than the errors during modeling.

       

    /

    返回文章
    返回