Skip to main content

Upper extremity physical performance tests in female overhead athletes: a test–retest reliability study

Abstract

Objective

Despite the studies that have investigated the reliability of Upper Extremity Functional Tests(UEFTs), the reliability of Closed Kinetic Chain Upper Extremity Stability(CKCUES), Seated Medicine Ball Throw(SMBT), push-up(PU) and Unilateral Seated Shot Put(USSP) tests in overhead athletes has yet to be assessed. The objective of this study was to determine both the relative and absolute test–retest reliability of the four UEFTs in female overhead athletes.

Methods

Twenty-nine female overhead athletes (age: 26.6 ± 5.29 years) underwent the four UEFTs twice within a three- day interval. The upper limb stability was assessed through PU and CKCUES tests, while the power was assessed though SMBT and USSP tests. The Intraclass Correlation of Coefficient (ICC) was applied to assess the relative reliability. Absolute reliability was determined by calculating the Standard Error of Measurement (SEM) and the Minimal Detectable Change (MDC). Furthermore, Bland–Altman plots were used to detect the agreements between the two measurements.

Results

The relative reliability of PU, CKCUES, SMBT, and non-dominant arm USSP tests was excellent (ICC = 0.83, 0.80, 0.91, and 0.83, respectively). SEM was within a range of 1.69 to 1.72 for stability tests and a range of 13.61 to 52.12 for power (based on a 95% confidence interval). The MDC was 4.68 for PU and 4.75 for CKCUES test. At least four repetitions are needed to be considered a real improvement on PU and CKCUES tests. This value was 144.04, in SMBT and 59.03, 37.62 cm (dominant and non-dominant arm, respectively) in USSP tests, which represents the minimum change that must occur to be considered an athlete’s progression.

Conclusion

This study revealed that both the upper limb stability and power tests have acceptable relative and absolute intra-rater reliability in female overhead athletes. These can be considered as reliable tools in research and clinical settings.

Introduction

The shoulder complex is a collective system of four interconnected joint articulations, each of which plays an important role in the shoulder range of motion (ROM). As the joints are interconnected, no single muscle can act alone in the shoulder complex and many related muscles must be involved to accomplish the movement of concern.

Overhead athletes are exposed to shoulder injuries due to the forceful and repetitive nature of their movements [1, 2], especially in throwing sports like baseball, volleyball, and badminton. The throwing shoulder must be sufficiently loose to allow a 180-degree flexion or abduction and yet stable enough to prevent injuries [1, 3]. If athletes returns to sport without a proper rehabilitation program concerning their functional stability and mobility, the risk of re-injury will be high. So, an accurate physical examination is necessary to make a delicate decision on the recovery of athletes following different shoulder injuries [4, 5]. Physical examinations should detect functional and biomechanical impairments in professional or daily life activities. Assessing ROM and muscle strength are standard components of physical examinations, yet they may not be sufficient in providing comprehensive information. To overcome this drawback, upper limb functional tests have been developed. These tests are many, some demonstrate stability and some mobility and power features of the shoulder. Consequently, they can provide quantitative evidence for the success and efficacy of rehabilitation programs [1, 2]. Among the tests that validated for measuring the functional stability of the upper extremity, Closed Kinetic Chain Upper Extremity Stability (CKCUES) and Push-up (PU) tests are more common since they are easily understood and administered, cost-effective, and are acceptable alternatives to the bench press repetitions-to-failure test [4, 6].

On the other hand, upper extremity power, as one of the essential properties of overhead athletes, can be assessed through Seated Medicine Ball Throw (SMBT) and Unilateral Seated Shot Put (USSP) tests [7]. Due to their feasibility, these tests are administered frequently to quantify upper body explosiveness in the practical setting.

However, due to the specific nature of all mentioned tests, clinicians and researchers select each test based on their specific assessment purposes. In other words, SMBT and USSP tests are used for the assessment of the upper extremity power; whereas CKCUES and PU tests are more suitable for neuromuscular control and stability evaluation of the upper limb. Therefore, it seems that an isolated performance test cannot accurately assess shoulder function in overhead athletes to decide on time to return to sport [8].

If an athlete returns to play without a proper rehabilitation program regarding their functional stability and mobility, the risk of re-injury will be high. Return to sport needs an accurate, precise and multi-dimensional assessment of the shoulder function. Although studies have shown that there is no consensus on criteria for returning to sport after shoulder injuries, in some studies, ROM, muscle strength, and time after injury are used as criteria. However due to the complexity of the shoulder joint, these criteria are not sufficient, and using the four functional tests can provide good information about shoulder function and athletes’ readiness to return to sport [9].

Isokinetic dynamometers are standard measurement equipment that objectively assess muscle strength as another important criterion. However, using them in non-laboratory settings is not feasible, so clinicians need an alternative assessment test such as SMBT [8].

Since Upper Extremity Functional Tests (UEFTs) are widely applied in different populations; many researchers have assessed their reliability. Goldbeck and Davies conducted the relative reliability of the CKCUES test on 24 male college students and revealed the test–retest intraclass correlation coefficient (ICC) to be 0.92 [4]. In studies conducted on men and women with and without shoulder pathologies, the relative reliability of CKCUES test was found excellent [10, 11]. Moderate to excellent reliability of CKCUES test was observed in adult and adolescent populations [12, 13]. Negrete et al. [5] found high reliability of modified pull-up, PU, and single arm shot put tests on healthy recreationally active adults. Davis et al. and Harris et al. reported high reliability of SMBT test in older adults and kindergarten children [14, 15].

Unlike the mentioned studies, the reliability of CKCUES, SMBT, PU, and USSP tests in overhead athletes, has not been assessed yet. In addition, most studies have only measured the relative reliability through ICC which cannot determine the measurement errors due to repeated assessments. The absolute reliability of Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC), is very important especially when the tests are run as a measure of performance improvement or clinically significant [10].

Therefore, the purpose of the present study was to determine both the relative and absolute test–retest reliability of four UEFTs in overhead athletes. Furthermore, the Bland–Altman method was adopted to reveal the agreement between the measurements, which was applied only in a few studies. The findings of this study would assist clinicians to choose appropriate tests and interpret the clinical data of overhead athletes.

Methods

Design The present research was conducted with a cross-sectional and methodological design. Written informed consent was signed by all participants and the study was approved by the Ethics Committee of the School of Rehabilitation of Tehran University of Medical Sciences. The following equation was applied to calculate the sample size:

$$C_{r} = {\raise0.7ex\hbox{$1$} \!\mathord{\left/ {\vphantom {1 2}}\right.\kern-0pt} \!\lower0.7ex\hbox{$2$}}\;Ln\;\frac{1 + r}{{1 - r}},\;n = \left( {\frac{{Z_{{\left( {1 - {\raise0.7ex\hbox{$\alpha $} \!\mathord{\left/ {\vphantom {\alpha 2}}\right.\kern-0pt} \!\lower0.7ex\hbox{$2$}}} \right)}} + Z_{{\left( {1 - \beta } \right)}} }}{{C_{r} }}} \right)^{2} + 3$$

Participants Twenty-nine female overhead recreational athletes (10 volleyball, 9 basketball, and 10 badminton players), within a range of 18–35 years volunteered to participate in the study (age 26.6 ± 5.29 years, height: 166.31 ± 5.6 cm, weight: 61.72 ± 10.54 kg) and were tested twice with a three-day interval period to decrease the likelihood of training effects.

The inclusion criteria were (1) female athletes aged 18 to 35, (2) active in overhead sports without any history of upper limb trauma or injury that had limited activity for more than two consecutive days in the past six months, and (3) without any systemic and neuromuscular disease. The exclusion criteria were a history of upper extremities or spinal surgery, and the use of hypnotic and sedative medications. The subjects were also excluded if they reported a new injury within the first two days of the test period, and pain or fatigue following the first trial [16, 17].

Procedures First, tests were completed in a random order, and then the athlete was instructed to perform the tests. Before each test, a five-minute routine warm-up plus 3 min of anterior shoulder stretch, horizontal adduction for posterior shoulder stretch, and trunk side-bending overhead reach were performed to stretch the trunk and inferior shoulder girdle [18,19,20].

Push-up test

The athletes assumed the modified PU position with their hands placed under their shoulders, fingers pointed forward, and elbows pointed backward (Fig. 1). The participants first held the position with a PU on full arm extension so their body weight would rest on their hands and toes. Then the athletes lowered themselves until all their body from the chest to the thighs made contact with the floor. Completing this process was counted as one successful PU test. The athletes completed as many repetitions as possible during 3 sets and rested 45 s between sets. One examiner controlled the stopwatch, and the other counted the touch count [5]. The PU score was the number of correct Pus [4, 5].

Fig. 1
figure 1

Starting position for push-up

Closed kinetic chain upper extremity stability test

During this test, the athletes performed the modified PU position (with knee support), and both hands placed on two adhesive tape markers affixed to the ground at a distance of 91.4 cm (Fig. 2). The athlete remained in the modified PU position with one hand on each piece of tape. Then, for 15 s, the athletes alternatively touched the opposite hand. The hand touch count is the score for this test. The athletes completed as many repetitions as possible during 3 sets and rested 45 s between each set. One examiner controlled the stopwatch, and the other the touch counts [4, 21].

Fig. 2
figure 2

Starting position for closed kinetic chain upper extremity stability test (CKCUEST)

Seated medicine ball throw test

This test was performed in a sitting position with a 2 kg medicine ball and a measuring tape. Athletes sat on the floor with their backs against a wall for support and their legs stretched out. Participants began by holding a 2 kg medicine ball with both hands and resting it on their chest (Fig. 3). They threw the ball with a chest press motion for distance. This distance was measured and recorded with the same measuring tape. To minimize the error, each participant was allowed three attempts with an interval of 1 min between each throw. One examiner measured the throw distance, and the other checked the athlete’s position [15, 22, 23].

Fig. 3
figure 3

Starting position for seated medicine ball throw (SMBT) test

Unilateral single-arm shot-put test

This test was performed using a 3 kg medicine ball [5, 24]. Athletes sat on the floor with their backs against the wall, knees bent at 90 degrees, and feet resting on the floor. The athletes were placed next to a doorway to allow unrestricted arm movement on the test side. Participants were instructed to hold the medicine ball at shoulder level and push it (not to throw) as far as possible (Fig. 4). The participant’s head and back were in contact with the wall and their non-engaged arm was on their lap. After 1 min, the test was repeated for the other side [24]. One examiner measured the ball's distance, and the other checked the athlete’s position.

Fig. 4
figure 4

Starting position for unilateral seated shot-put (USSP)Test

All four UEFTs were repeated three times and the mean was calculated. The subjects rested for 3 min between each main test.

Statistical analysis

SPSS version 23.0(SPSS Inc., Chicago, IL, USA) was used for data analysis and significance was set at p < 0.05. The normality of distribution was assessed by the Kolmogorov–Smirnov test. The relative reliability was calculated using ICC(2, 1). ICC values above 0.75 were considered excellent reliability. Values between 0.40 and 0.74 represented moderate while below 0.40 showed poor reliability[25].

Absolute reliability, expressed as SEM, was evaluated to determine the precision of each score. MDC was also calculated to estimate the threshold for measurement error. The MDC is the minimum change in score that an individual must experience to ensure that the change in score is not simply due to measurement error.

The equations of these tests were:

$${\text{SEM}} = {\text{ SD}} \times \sqrt {\left( {{1} - {\text{ICC}}} \right)}$$
$${\text{MDC}} = {\text{SEM }} \times { 1}.{96} \times \sqrt 2$$

Then MDC percentage was calculated by dividing MDC into the maximal score of the measurement. MDC percentages less than 30 and 10 are considered acceptable and excellent, respectively. For SEM, the values equal to 0 are considered perfectly reliable while the values equal to SD are interpreted as completely unreliable [26]. The coefficient of variation (CV) was calculated as the SD to the mean ratio (CV = SD/Mean × 100) to show the extent of variability.

A paired t-test was also used to show the differences in the mean scores between the two test sessions. The Bland and Altman chart was plotted for each test to provide a visual interpretation of the agreement between the two assessment sessions.

Results

The demographic information of the athletes are presented in Table 1. No significant difference between test sessions for either the stability or power tests (P > 0.05) was observed in the paired t-test (Table 2), revealing that there is no systematic bias.

Table 1 Demographic characteristics of study populations (n = 29)
Table 2 Paired t-test comparing test–retest scores among upper extremity functional tests

Relative reliability

ICC values of all tests were within a range of 0.65 to 0.91, suggesting moderate to excellent reliability. The PU, CKCUES, SBMT, and USSP (non-dominant hand) tests had excellent reliability, and the USSP test in the dominant hand showed moderate reliability (Table 3).

Table 3 Test–retest reliability indices of the functional tests

Absolute reliability

SEM, MDC and CV values are tabulated in Table 3. The Bland and Altman charts are demonstrated for the four functional tests in Table 4 and Figs. 5, 6, 7, 8 and 9.

Table 4 Bland and Altman analysis of the tests
Fig. 5
figure 5

Bland–Altman plot for push-up test

Fig. 6
figure 6

Bland–Altman plot for seated medicine ball throw (SMBT) test

Fig. 7
figure 7

Bland–Altman plot for closed kinetic chain upper extremity stability test (CKCUEST)

Fig. 8
figure 8

Bland–Altman Plot for unilateral seated shot put (non-dominant arm) test

Fig. 9
figure 9

Bland–Altman Plot for unilateral seated shot put (dominant arm) test

Discussion

The objective of this study was to determine the test–retest reliability within a three-day interval for PU, CKCUES, SMBT, and USSP tests in female overhead athletes. Due to the specific property of the test–retest reliability, we assessed ICCs (95% CI), SEM, MDC, and CV. The mean scores and differences in test indices between the two measurement sessions were assessed by paired t-test. Bland and Altman’s plots were demonstrated. Generally, to our knowledge, the novelty of this study was (1) simultaneous assessment of reliability for two stability and two power upper limb functional tests, (2) reliability assessment in female overhead athletes, and (3) comprehensive assessment of the reliability by assessing the six parameters/methods.

The findings of this study showed excellent relative reliability for both the stability and power tests except for the dominant arm USSP test which showed moderate reliability. The findings of relative reliability for PU, CKCUES, and SMBT tests were in agreement with that of Harris, Davis, Negrete, Sciascia, and Goldbeck et al., where only one or some of the above tests were assessed [4, 5, 11, 14, 15]. In the present study, the pushing distance during USSP test increased from 256.28 to 262.24 cm in the dominant hand and from 235.9 to 241.83 cm in the non-dominant hand, making ICC moderate in the dominant hand and excellent in the non-dominant hand. These values were less those reported by Negrete et al. and Degoat et al. [20, 27], which may probably be due to the difference in throwing technique and the statistical population. In their study, recreationally active adults threw the ball while sitting on a chair, but in our study, athletes sat on the floor. The ball weight and the athletes’ gender are different in these two studies as well. The result of the present study was in agreement with Davis for SBMT test that showed medicine ball throw is highly reliable within 1 day (ICCs = 0.93) [14]. For CKCUES test, our findings were in agreement with Goldbeck that showed the ICC was 0.922 for test–retest reliability and reported CKCUES test as a reliable evaluation tool [4].

The dominant shoulder of overhead athletes is different from that of the non-athletes and the type of each overhead activity as well [28]. The ICC for SMBT test was excellent in this study and in agreement with and Beckham, Koo and Li, Gillespie, and Kenum et al.’s findings. The correlation of these results revealed that distance measurement through SBMT test is a reliable test for assessing upper limb power [29,30,31].

Good ICC for PU test was found to be within a range of 0.65 to 0.92 in this study, which is supported by Bohannon’s 0.87 to 0.90 range and Gillen et al.’s range of 0.65 to 0.79[32].

Absolute reliability

The SEM value for PU and CKCUES tests was 1.69 and 1.72, respectively. The MDC values in PU and CKCUES tests were 4.68 (21.27%), and 4.75 (20.36%), respectively. These values would assure clinicians that at 95% confidence, the changes over 4 repitations were considered the true improvement. In general, the lower the SEM and MDC values, the more reliable the measurements[33].

The values obtained through SEM for CKCUES test were close to those of Sciascia et al. and Tucci et al. at 2 and 2–2.76 touches, respectively. As MDC, the same holds for findings at 4 and 2.82–3.91, respectively [10, 11]. In this study, the SEM and MDC values for the PU test were greater than that of Negrete et al.’s study (1 and 2 repetitions), respectively, which involved both genders [20]. The female athletes in this study took the test in a modified position (putting their knees on the floor).

The SEM value in SMBT in our study (52.12 cm) was greater than the one found by Harris et al. (14.8–19.1 cm) and by Beckham et al. (14 cm) [15, 29].

This could be related to the difference in age and athletic performance of the participants [15]. The difference in ball weight is another factor. The MDC value was absent in Harris et al. [15] and Beckham et al.’s [29] findings.

The SEM values in this study for dominant and non-dominant USSP were 21.36 and 13.61, and the MDC values were 59.03 and 37.62, respectively. Regarding SEM and MDC, there existed only 3 studies where these values in addition to the ICC were of concern. These values were different from our study, which could be related to the reasons discussed earlier in the relative reliability section. The typical error (or the coefficient of variation percent) for SMBT and USSP (dominant and non-dominant hand) was 1%, while PU and CKCUES tests had a 5% error. All the tests in this study had values lower than 10%, which is considered valid. This is in line with Degot’s study which found a 5.02% error for USSP test [27]. The mean CV for the first and second trials of SBMT test was 4.2%, a higher result than ours [29]. The CV for CKCUES test was reported in the Degot’s study to be 10.3% which is not commonly observed in other studies. This value was significantly higher than the one obtained in our study [34]. The lower values of CV in this study compared to the mentioned studies may be attributed to the population. In other words, in the present study only women participated and all were in the same sport category, i.e. overhead sports.

Bland–Altman analysis

This analysis is a supplement for the other reliability indices (ICC, SEM, MDC, and CV). To the researchers’ knowledge, this analysis was run in a few studies to determine the reliability of the four functional tests in overhead athletes [13, 27, 29, 35, 36]. As observed in Figs. 5, 6, 7, 8 and 9, there exists one outlier for PU and both USSP tests and two outliers for CKCUES and SMBT tests. In this study, according to USSPT, the higher score (further throw) indicates less agreement. In the case of CKCUES, the lower score (fewer touches) indicates better agreement.

Future studies are needed to compare the reliability of women overhead athletes with men and to assess the reliability of these tests in other athletic disciplines like gymnastics and wrestling which use weight-bearing positions. In this study, the tests were not normalized to body dimensions (e.g. weight and height). It is suggested that future studies consider this issue.

Conclusions

The four upper extremity functional tests have excellent reliability in overhead athletes, except for the dominant USSP test, which revealed moderate reliability. These low-cost, easy-to-run tests would help the sports clinicians in assessing the shoulder function and athletes’ sport readiness.

Based on the absolute reliability findings, the clinicians can apply the reported scores here as a reference to detect the real improvement in either a group or a single female overhead athlete(s).

Clinical relevance

  • Push-up test, Closed Kinetic Chain Upper Extremity Stability test, Seated Medicine Ball Throw test, and Unilateral Seated Shot Put test (non-dominant hand) have excellent reliability.

  • Sports clinicians can apply these low-cost, easy-to-operate tests to examine the improvement of the athletes or patients with similar dysfunctions

  • The clinicians can apply the scores found here as a reference in detecting the real improvement in either a group or a single female overhead athlete(s).

References

  1. Wilk KE, Yenchak A, Arrigo CA, Andrews JR. The advanced throwers ten exercise program: a new exercise series for enhanced dynamic shoulder control in the overhead throwing athlete. Phys Sportsmed. 2011;39(4):90–7.

    Article  PubMed  Google Scholar 

  2. Krishnan SG, Hawkins RJ, Warren RF. The shoulder and the overhead athlete. Lippincott Williams & Wilkins: Philadelphia; 2004.

  3. Beckham G, Lish S, Disney C, Keebler L, DeBeliso M, Adams KJ. The reliability of the seated medicine ball throw as assessed with accelerometer instrumentation. J Phys Act Res. 2019;4(2):131–6.

    Google Scholar 

  4. Goldbeck TG, Davies GJ. Test-retest reliability of the closed kinetic chain upper extremity stability test: a clinical field test. J Sport Rehabil. 2000;9(1):35–45.

    Article  Google Scholar 

  5. Negrete RJ, Hanney WJ, Kolber MJ, Davies GJ, Ansley MK, McBride AB, et al. Reliability, minimal detectable change, and normative values for tests of upper extremity function and power. J Strength Cond Res. 2010;24(12):3318–25.

    Article  PubMed  Google Scholar 

  6. Kennedy DJ, Visco CJ, Press J. Current concepts for shoulder training in the overhead athlete. Curr Sports Med Rep. 2009;8(3):154–60.

    Article  PubMed  Google Scholar 

  7. Mayhew JL, Bemben MG, Piper FC, Ware JS, Rohrs DM, Bemben DA. Assessing bench press power in college football players: the seated shot put. J Strength Cond Res. 1993;7(2):95–100.

    Google Scholar 

  8. Borms D, Maenhout A, Cools AM. Upper quadrant field tests and isokinetic upper limb strength in overhead athletes. J Athl Train. 2016;51(10):789–96.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Griffith R, Fretes N, Bolia IK, Murray IR, Meyer J, Weber AE, et al. Return-to-sport criteria after upper extremity surgery in athletes—A scoping review, part 1: rotator cuff and shoulder stabilization procedures. Orthop J Sports Med. 2021;9(8):23259671211021828.

    PubMed  PubMed Central  Google Scholar 

  10. Tucci HT, Martins J, de Carvalho SG, Camarini PMF, de Oliveira AS. Closed Kinetic Chain Upper Extremity Stability test (CKCUES test): a reliability study in persons with and without shoulder impingement syndrome. BMC Musculoskelet Disord. 2014;15(1):1–9.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Sciascia A, Uhl T. Reliability of strength and performance testing measures and their ability to differentiate persons with and without shoulder symptoms. Int J Sports Phys Ther. 2015;10(5):655.

    PubMed  PubMed Central  Google Scholar 

  12. Lee D-R, Kim LJ. Reliability and validity of the closed kinetic chain upper extremity stability test. J Phys Ther Sci. 2015;27(4):1071–3.

    Article  PubMed  PubMed Central  Google Scholar 

  13. de Oliveira VM, Pitangui AC, Nascimento VY, da Silva HA, Dos Passos MH, de Araújo RC. Test-retest reliability of the closed kinetic chain upper extremity stability test (CKCUEST) in adolescents: reliability of CKCUEST in adolescents. Int J Sports Phys Ther. 2017;12(1):125.

    PubMed  PubMed Central  Google Scholar 

  14. Davis KL, Kang M, Boswell BB, DuBose KD, Altman SR, Binkley HM. Validity and reliability of the medicine ball throw for kindergarten children. J Strength Cond Res. 2008;22(6):1958–63.

    Article  PubMed  Google Scholar 

  15. Harris C, Wattles AP, DeBeliso M, Sevene-Adams PG, Berning JM, Adams KJ. The seated medicine ball throw as a test of upper body power in older adults. J Strength Cond Res. 2011;25(8):2344–8.

    Article  PubMed  Google Scholar 

  16. Falsone SA, Gross MT, Guskiewicz KM, Schneider RA. One-arm hop test: reliability and effects of arm dominance. J Orthop Sports Phys Ther. 2002;32(3):98–103.

    Article  PubMed  Google Scholar 

  17. Roush JR, Kitamura J, Waits MC. Reference values for the closed kinetic chain upper extremity stability test (CKCUEST) for collegiate baseball players. North Am J Sports Phys Ther NAJSPT. 2007;2(3):159.

    Google Scholar 

  18. Van den Tillaar R, Marques MC. Reliability of seated and standing throwing velocity using differently weighted medicine balls. J Strength Cond Res. 2013;27(5):1234–8.

    Article  PubMed  Google Scholar 

  19. Stockbrugger BA, Haennel RG. Contributing factors to performance of a medicine ball explosive power test: a comparison between jump and nonjump athletes. J Strength Cond Res. 2003;17(4):768–74.

    PubMed  Google Scholar 

  20. Negrete RJ, Hanney WJ, Pabian P, Kolber MJ. Upper body push and pull strength ratio in recreationally active adults. Int J Sports Phys Ther. 2013;8(2):138.

    PubMed  PubMed Central  Google Scholar 

  21. Schulte-Edelmann JA, Davies GJ, Kernozek TW, Gerberding ED. The effects of plyometric training of the posterior shoulder and elbow. J Strength Cond Res. 2005;19(1):129–34.

    PubMed  Google Scholar 

  22. Jones M, Lorenzo D. Assessment of power, speed, and agility in athletic, preadolescent youth. J Sports Med Phys Fitness. 2013;53(6):693–700.

    CAS  PubMed  Google Scholar 

  23. Ferreira LGR, de Oliveira AS, do Carmo ND, Bueno GAS, Lemos TV, Matheus JPC, et al. Reliability and validity of the one arm hop test and seated medicine ball throw test in young adults: a cross-sectional study. J Bodywork Mov Ther. 2021;28:26–33. https://doi.org/10.1016/j.jbmt.2021.07.018.

    Article  Google Scholar 

  24. Chmielewski TL, Martin C, Lentz TA, Tillman SM, Moser MW, Farmer KW, et al. Normalization considerations for using the unilateral seated shot put test in rehabilitation. J Orthopaed Sports Phys Ther. 2014;44(7):518–24.

    Article  Google Scholar 

  25. Fleiss JL. Design and analysis of clinical experiments: Wiley; 2011.

  26. Scinicarelli G, Trofenik M, Froböse I, Wilke C. The reliability of common functional performance tests within an experimental test battery for the lower extremities. Sports. 2021;9(7):100.

    Article  PubMed  PubMed Central  Google Scholar 

  27. Degot M, Blache Y, Vigne G, Franger G, Neyton L, Rogowski I. Intra-and intersession reliability and agreement of the unilateral seated shot-put test outcome measures in healthy male athletes. BMC Sports Sci Med Rehabil. 2021;13(1):1–7.

    Article  Google Scholar 

  28. Christoforetti JJ, Carroll RM. The thrower’s shoulder. Curr Opin Orthop. 2005;16(4):246–51.

    Article  Google Scholar 

  29. Beckham G, Lish S, Keebler L, Longaker C, Disney C, DeBeliso M, et al. The reliability of the seated medicine ball throw for distance. J Phys Act Res. 2019;4(2):131–6.

    Google Scholar 

  30. Gillespie J, Keenum S. A validity and reliability-analysis of the seated shot put as a test of power. J Hum Mov Stud. 1987;13(2):97–105.

    Google Scholar 

  31. Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155–63.

    Article  PubMed  PubMed Central  Google Scholar 

  32. Bohannon NA, Gillen ZM, Shoemaker ME, McKay BD, Gibson SM, Cramer JT. Test-retest reliability of static and countermovement power push-up tests in young male athletes. J Strength Cond Res. 2020;34(9):2456–64.

    Article  PubMed  Google Scholar 

  33. Liaw L-J, Hsieh C-L, Lo S-K, Chen H-M, Lee S, Lin J-H. The relative and absolute reliability of two balance performance measures in chronic stroke patients. Disabil Rehabil. 2008;30(9):656–61.

    Article  PubMed  Google Scholar 

  34. Degot M, Blache Y, Vigne G, Juré D, Borel F, Neyton L, et al. Intrarater reliability and agreement of a modified closed kinetic chain upper extremity stability test. Phys Ther Sport. 2019;38:44–8.

    Article  PubMed  Google Scholar 

  35. Xu H-R, Zhang Y-H, Mao Y, Ngo TL, Zhang Q, He G, et al. Validity and reliability of upper extremity star excursion balance test in adolescent swimmers. J Exerc Sci Fit. 2023;21(2):210–7.

    Article  PubMed  PubMed Central  Google Scholar 

  36. Henriques-Neto D, Minderico C, Peralta M, Marques A, Sardinha LB. Test–retest reliability of physical fitness tests among young athletes: the FITescola® battery. Clin Physiol Funct Imag. 2020;40(3):173–82.

    Article  Google Scholar 

Download references

Acknowledgements

Authors would like to acknowledge Tehran University of Medical Sciences for their support.

Funding

This research has not received any grants from funding agencies in the public, commercial, or not-for-profit sectors.

Author information

Authors and Affiliations

Authors

Contributions

SK: Methodology, Data collection and analysis; Writing-Original draft; ZG: Data analysis, Writing final manuscript, Revision for critically intellectual content; NG: Study concept and design, Supervision, Writing final manuscript, Revision for critically intellectual content; BA: Study concept, Methodology; AS: Study concept, Methodology; MG: Writing-Review and Editing. All authors reviewed the manuscript.

Corresponding author

Correspondence to Nastaran Ghotbi.

Ethics declarations

Ethics approval and consent to participate

This study was approved by the Ethic Committee of School of Rehabilitation, Tehran University of Medical Sciences. All participants signed an informed consent.

Competing interests

There is no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kardor, S., Gorji, Z., Ghotbi, N. et al. Upper extremity physical performance tests in female overhead athletes: a test–retest reliability study. J Orthop Surg Res 18, 489 (2023). https://doi.org/10.1186/s13018-023-03974-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-023-03974-4

Keywords