Skip to main content
  • Research article
  • Open access
  • Published:

Qualitative and quantitative evaluation of acute angle-closure mechanisms

Abstract

Background

To evaluate ocular biometric parameters in different subtypes of acute angle closure and compared to fellow eyes of AAC and PACS eyes.

Methods

This is a retrospective chart review study. A total of 167 eyes (96 patients) consisting of 71 AAC eyes, 71 fellow eyes of AAC, and 25 PACS eyes were recruited. All patients underwent ocular examination and biometry. The mechanism of AAC was confirmed by ultrasound biomicroscopy. We then subdivided AAC eyes into four subgroups: crowded-angle (CR), lens subluxation (LS) pupillary block (PB), and plateau iris syndrome (PL). Outcome variables included anterior chamber depth (ACD), lens thickness (LT), vitreal length (VL), axial length (AL), lens position and relative lens position (LP and RLP, respectively), and lens axial length factor (LAF).

Results

Among the three groups, ACD was shallower in AAC eyes than fellow eyes of AAC and PACS eyes (p < 0.01 for both) and AAC eyes demonstrated a lesser LP and RLP. The LT, VL, AL, and LAF were not significantly different among the three groups. Among the four subgroups, LS displayed the most shallow ACD (p = 0.01). The lens position in PL was greater than in CR and LS (p < 0.05 and <0.01, respectively).

Conclusions

AAC eyes had a more anterior lens position than fellow eyes and PACS eyes, though lens thickness did not differ among the groups. As such, an anterior lens position may offer more sensitive prognostication regarding future development of AAC compared to lens thickness.

Peer Review reports

Background

Acute angle-closure (AAC) is a potentially blinding ophthalmic emergency that requires prompt treatment to markedly lower the increased intraocular pressure (IOP) [1]. Acute primary angle-closure is a bilateral, asymmetrical condition that frequently involves the fellow eye [2]. Several ocular biometric parameters have been identified for angle-closure development, such as small corneal diameter [2], small radius of the anterior and posterior corneal curvature [2], short axial length, shallow central and peripheral anterior chamber depth [3, 4], thick and anteriorly positioned lens [5,6,7,8], and a large lens axial length factor [9, 10].

Ultrasound biomicroscopy (UBM) can be used to determine the mechanisms of AAC by demonstrating the relationship between the peripheral iris, ciliary body, and trabecular meshwork [11]. UBM can also demonstrate both static and dynamic images of the anterior chamber. In contrast, although anterior segment optical coherence tomography visualizes the angle well, it generally cannot sufficiently image the ciliary body. This limitation precludes appreciation of a plateau iris (particularly if the cornea is edematous, thereby precluding gonioscopy).

There have been several studies comparing biometric parameters among AAC, fellow eyes, or primary angle-closure suspect (PACS) eyes in an attempt to identify risk factors that may contribute to an acute episode [5, 7, 12,13,14,15]. However, to our knowledge, few studies have analyzed the differences in biometric parameters between distinct mechanisms of acute angle-closure. We recently reported mechanisms of AAC classified by UBM.

A study of the biometric parameters associated with angle-closure will further expand our understanding regarding pathologic mechanisms and guide us toward more effective diagnoses and treatments.

Methods

This study was conducted by retrospective chart review of consecutive patients who presented with the diagnosis of either AAC or PACS to the Department of Ophthalmology, Ramathibodi Hospital, Mahidol University, Thailand, from June 2011 to February 2015. This study was approved by Ramathibodi Hospital, Mahidol University Ethic Committee. The study was Health Insurance Portability and Accountability Act compliant and adhered to the tenets of the Declaration of Helsinki. Written informed consent was obtained from all subjects. We utilized UBM to determine the mechanism of angle-closure in 71 AAC eyes, 71 fellow eyes of AAC, and 25 PACS eyes. Each patient also was examined by A-scan ultrasound biometry.

Three groups were examined.

  1. 1.

    AAC was defined as: (1) presence of at least one of the following symptoms: periocular pain or headache, nausea and/or vomiting, decreased vision, and/or antecedent history of intermittent rainbow-colored halos around lights; (2) documentation of presenting IOP ≥ 21 mmHg (as measured by Goldmann applanation tonometry); (3) presence of iridotrabecular contact more than 180° on gonioscopy; and (4) slit-lamp biomicroscopic findings of at least four of the followings: ciliary injection, corneal epithelial edema, fixed mid-dilated pupil, glaukomflecken, and shallow peripheral anterior chamber.

  2. 2.

    A fellow eye of AAC was defined as: (1) presence of iridotrabecular contact of more than 180° on gonioscopy, and (2) no history or signs of previous AAC attack.

  3. 3.

    PACS was defined as: (1) presence of iridotrabecular contact more than 180° without PAS on gonioscopy; (2) the absence of a glaucomatous optic nerve and visual field damage; (3) no history or signs of a previous AAC attack; and (4) an IOP of <21 mmHg without medication.

Exclusion criteria included: (1) an open-angle (>180°) on gonioscopic examination before use of anti-glaucoma medication; (2) a history of laser peripheral iridoplasty laser pupilloplasty surgical peripheral iridectomy cataract or filtering surgery; (3) secondary angle-closure such as ocular trauma neovascularization of the iris uveitis or lens intumescence with significantly different cataract severity between eyes (i.e. phacomorphic glaucoma); (4) patients with cataract surgery or goniosynechialysis prior to UBM; and (5) cases of bilateral acute angle-closure.

Standard demographic and ophthalmic data were also recorded: age, sex, laterality of affected eye, presenting IOP, A-scan biometry (axial length (AL), anterior chamber depth (ACD), lens thickness (LT), vitreous length (VL), and UBM to evaluate the underlying mechanisms of AAC.

We classified all AAC subgroups into four categories: pupillary block (PB), crowded-angle (CR), anterior lens subluxation (LS), and plateau iris syndrome (PL) (Fig. 1).

Fig. 1
figure 1

Ultrasound biomicroscopic images demonstrate angle-closure mechanisms in AAC. a pupillary block; b crowded-angle; c plateau iris, and d anterior lens subluxation

PB was defined as: (1) characteristic iris bombé on gonioscopy, and (2) convex iris configuration on UBM with decreased iridolenticular contact under dark illumination in at least three quadrants.

PL was defined as: (1) iridotrabecular apposition in the presence of a patent iridectomy as revealed by gonioscopy, anteriorly and centrally angled peripheral iris, a flat or slightly convex iris, and/or the sign of a double hump signifying the formation of anterior concavity of the iris at the lens equator level and ciliary body on the indentation gonioscopy; (2) absence of pupillary block; (3) UBM diagnosis of PL with anteriorly directed ciliary body, an absent ciliary sulcus, a steep iris approach from its point of insertion followed by a downward angulation from the corneoscleral wall, presence of a central flat iris plane, iridotrabecular contact in at least three quadrants; and (4) presence of a patent iridotomy.

CR was defined as: (1) iridotrabecular contact more than 180° in the presence of visible ciliary processes and volcanic iris configuration on gonioscopic examination, and (2) UBM diagnosis indicating shallow central and peripheral anterior chamber depth and increased iridolenticular contact distance.

LS was defined as: (1) iridotrabecular contact more than 180° on gonioscopic examination and slit-lamp biomicroscopy showing phacodonesis, tilting of lens, and/or visible vitreous in anterior or posterior chamber; and (2) UBM diagnosis showing shallow central and peripheral anterior chamber depth, tilting of lens, asymmetrical ACD in the same eye, and/or asymmetrical iris configuration.

A-scan ocular biometry

In this study, A-scan ultrasound biometry (OcuScan®RxP Ophthalmic Ultrasound, Alcon, Ft Worth Tx, USA) was used to measure AL, ACD, LT, and VL. Care was taken not to exert pressure on the cornea by using the immersion technique. Measurements were made by trained technicians and repeated until three successive values within 0.1 mm for ACD and 0.3 mm for AL were obtained. These data were used to calculate lens position (LP = ACD + \( \frac{1}{2} \) LT), relative lens position (RLP = \( \frac{\mathrm{LP}}{\mathrm{AL}} \) × 10), and lens axial length factor (LAF = \( \frac{\mathrm{LT}}{\mathrm{AL}} \) × 10).

Qualitative UBM analysis

The UBM measurements were performed by one of three experienced-glaucoma specialists (YS, CT, or WS) who used the UBM with a 50-MHz transducer probe (Aviso, Quantel Medical, Bozeman, MT, USA). The measurements were obtained at the 3, 6, 9, and 12 o’clock positions of both eyes of each subject in the supine position. UBM assessments were carried out in dark (2 lx) and bright (400 lx) illumination to determine the dynamic changes of the iridocorneal relationship. The most pronounced feature that contributed to AAC development, as determined by the agreement of two of the three glaucoma specialists was classified as the primary mechanism.

Statistical analysis

Statistical analysis was performed using STATA software version 12 (StataCorp, College Station, Texas, USA). Continuous variables were analyzed using the analysis of variance (ANOVA) or Kruskal-Wallis test depending on data distribution. Categorical variables were analyzed by the Fisher Exact Probability test. Logistic regression analysis including checks for multicollinearity was performed. The dependent variable was AAC vs. PACS. Our sample size had a 100% power to detect 0.32-mm difference in ACD between AAC and PACS eyes using a type I error of 0.05. A p-value of less than 0.05 was considered statistically significant.

Results

A total of 167 eyes (96 patients) with angle-closure were recruited, consisting of 71 AAC eyes, 71 fellow eyes of AAC, and 25 PACS eyes. Four fellow eyes were pseudophakic and were excluded from analysis. There was no significant difference in mean age between AAC/fellow eye subjects and PACS subjects (63.3 ± 7.5 vs. 62.5 ± 6.1 years, p = 0.90). Although there was a female preponderance in each group, there was no difference in gender distribution between the groups (p = 0.94).

In AAC eyes, the ACD was significantly shallower compared to each of the other two groups (p < 0.001 for both). However, there was no significant difference in ACD between fellow eyes of AAC and PACS eyes (p = 0.99) (Table 1).

Table 1 Demographic characteristics of AAC mechanisms

The LP and RLP of AAC eyes were significantly lesser compared to each of the other two groups (p < 0.01 and <0.01, respectively). However, no significant difference was found in the LP and RLP between fellow eyes of AAC and PACS eyes (p = 0.35 and 0.95, respectively).

The LT, VL, AL, and LAF were not significantly different among the three groups.

Further analysis with logistic regression analysis confirmed statistical significance of ACD, LP, and RLP. Furthermore, though not statistically significant, all ocular biometric parameters in fellow eyes of AAC had slightly smaller ocular dimensions than the PACS eyes (p = 0.29, 0.93, and 0.24 for LT, VL, and AL, respectively).

AAC eyes were then subdivided into the following four subgroups based on gonioscopic findings and UBM: crowded-angle (CR), lens subluxation (LS), pupillary block (PB), and plateau iris syndrome (PL). There was no significant difference in age among the four subgroups (Table 2). However, a significant difference in gender was present among the four subgroups. The range of male-to-female ratios extended from the PL group, in which there were no male patients, to the LS group, in which the ratio was 1:1.3.

Table 2 Ocular Biometric Parameters of AAC eyes, Fellow Eyes of AAC, and PACS eyes

The differences in ocular biometric parameters among each AAC mechanism were analyzed (Tables 3 and 4). The ACD was greater in the PL group compared to the CR and LS groups, though there was no significant difference in ACD among CR, LS, and PB. Overall, there was a trend toward a deeper ACD, and from shallow to deep, the subgroups ranked: LS, CR, PB, and PL.

Table 3 Ocular Biometric Parameters Among Each Acute Angle-Closure Mechanism
Table 4 Post Hoc Analysis of Ocular Biometric Parameters Among Each Acute Angle-Closure Mechanism Using Tukey’s HSD

The LP was greater in the PL subgroups compared to the PB, CR, and LS subgroups. The LP was smaller in the LS subgroup compared to the CR, PB, and PL subgroups. No significant difference was found in LP between CR and PB. Overall, there was a trend toward a greater lens position, and from smallest to greatest, the subgroups ranked: LS, CR, PB, and PL. Results regarding RLP were similar to LP (Table 4).

The LAF was greater in the CR subgroup compared to the LS subgroup. The VL was the greatest in the LS subgroup compared to all other subgroups. The AL and LT were not significantly different among the three groups.

The Area under the Receiver Operating Characteristic using an ACD of 1.90 mm to distinguish the PL group from all other groups was 0.846.

Subsequent age- and gender-adjusted analysis of ocular biometric parameters for each acute angle-closure mechanism is presented in Table 5.

Table 5 Multinomial logistic regression analysis of ocular biometric parameters among each acute angle-closure mechanism (adjusted for age and gender)

Given the significant differences in ACD, LP, and RLP, we compared these parameters in the four subgroups to their respective fellow eyes. The ACDs of the CR and LS subgroups were significantly shallower compared to the ACDs in their respective fellow eyes (1.7 and 1.6 vs 2.1, p < 0.01 for both). The LP and RLP of the CR, LS, and PB subgroups were significantly less than in the fellow eyes [(LP: 4.3 vs 4.6, 4.1 vs 4.6, and 4.4 vs 4.6; p = < 0.01 for CR, LS, and PB) and (RLP: 1.9 vs 2.0, 1.8 vs 2.0, and 1.9 vs 2.0; p < 0.01 for CR, LS, and PB), respectively].

Discussion

Prior anterior segment imaging studies have identified several biometric parameters in eyes with AAC that differ from normal or fellow eyes, including a shallow anterior chamber [2, 4, 16], a thicker lens [2, 4, 16, 17], a more anterior lens position [2, 4, 17], and a shorter axial length [2, 4, 16, 17]. However, differences among the individual mechanisms of AAC have not been widely evaluated.

This study showed that AAC eyes have a shallower ACD and a more anterior LP and RLP compared to fellow eyes of AAC and PACS eyes. However, in contrast to previous studies [8, 12], our study did not find significant differences in LT or LAF between AAC eyes and either fellow eyes of AAC or PACS eyes [8, 12], potentially due to our strict exclusion of eyes in which the fellow eye contained an intumescent lens.

ACD may provide a useful clinical tool in the identification of CR and LS. First, CR and LS were the two most prevalent AAC mechanisms, suggesting that, in our study population, an AAC eye is more likely to have CR and LS versus PB and PL. Second, CR and LS demonstrated a significantly shallower ACD compared to the fellow eyes, whereas PL and PB did not. Similarly, albeit not statistically significant, CR and LS exhibited the shallowest ACD among the four AAC subgroups. Third, CR had the smallest AL and the greatest LAF among four groups, suggesting the potential important of small ocular dimensions in identifying CR.

Although PL had the deepest ACD among our subgroups, it was still shallow when compared to the ACD in PL measured in prior studies (2.80–3.14 mm) [18,19,20]. This surprising finding may be explained firstly by the frequent mixed mechanisms that often underlie AAC. For example, in patients with AAC, increased IOP or recurrent AAC in the presence of a patent peripheral iridotomy may suggest the formation of peripheral anterior synechiae or the influence of non-pupillary block mechanisms [21]. Second, the average age of our subjects (60.2 ± 6.9 years) was greater than in previous reports [18, 22]. As the lens thickens with age, the anterior chamber may become more shallow, thereby leading to a more complex clinical presentation [17, 19]. Overall, our findings corroborate prior studies in demonstrating a greater degree of ACD variability in PL compared to other mechanisms [19, 22,23,24,25].

This study had several limitations. First, the results of our study were limited by the characteristics of Ramathibodi Hospital as a referral center. The profiles of the patients likely represent one end of the spectrum of patients with AAC. Second, we analyzed biometric parameters regardless of iridotomy status, though nearly one-half of the patients had undergone iridotomy prior to UBM examination. As such, it was difficult to define all mechanisms responsible for certain AAC eyes. Third, our criteria for exclusion of secondary lens subluxation centered on a history of ocular trauma, as zonular status (e.g. disruption or laxity) could not be determined by slit lamp biomicroscopy or UBM. Fourth, the retrospective nature of this study resulted in exclusion of incomplete patient charts. Fifth, the small sample sizes of the subgroups may not have provided enough statistical power to demonstrate significant differences among mechanisms in terms of AL, LT, and LAF.

Conclusions

The anterior position of the lens was the important factor for AAC development in our patients. CR was the most contributory mechanism to AAC development among the predisposed eyes. This finding provides a better understanding regarding to the role of the lens in the pathogenesis of acute angle-closure and emphasizes the implications of cataract extraction. In our study, the mean age for subjects with plateau iris was greater than in previous studies, which may have led to a more complex clinical presentation and smaller ACD. Further studies with larger sample sizes are warranted in order to elucidate the overall mechanisms responsible for AAC development in individual patients.

Abbreviations

AAC:

Acute angle closure

ACD:

Anterior chamber depth

AL:

Axial length

CR:

Crowded angle

IOP:

Intraocular pressure

LAF:

Lens axial length factor

LP:

Lens position

LS:

Lens subluxation

LT:

Lens thickness

PACS:

Primary angle closure suspect

PB:

Pupillary block

PL:

Plateau iris syndrome

RLP:

Relative lens position

UBM:

Ultrasound biomicroscopy

VL:

Vitreous length

References

  1. Aung T, Friedman DS, Chew PT, Ang LP, Gazzard G, Lai YF, Yip L, Lai H, Quigley H, Seah SK. Long-term outcomes in asians after acute primary angle closure. Ophthalmol. 2004;111:1464–9.

    Article  Google Scholar 

  2. Tomlinson A, Leighton DA. Ocular dimensions in the heredity of angle-closure glaucoma. Br J Ophthalmol. 1973;57:475–86.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  3. Lowe RF, Clark BA. Posterior corneal curvature. Correlations in normal eyes and in eyes involved with primary angle-closure glaucoma. Br J Ophthalmol. 1973;57:464–70.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  4. Lowe RF. Aetiology of the anatomical basis for primary angle-closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle-closure glaucoma. Br J Ophthalmol. 1970;54:161–9.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  5. Lim MC, Lim LS, Gazzard G, Husain R, Chan YH, Seah SK, Aung T. Lens opacity, thickness, and position in subjects with acute primary angle closure. J Glaucoma. 2006;15:260–3.

    Article  PubMed  Google Scholar 

  6. Tarongoy P, Ho CL, Walton DS. Angle-closure glaucoma: the role of the lens in the pathogenesis, prevention, and treatment. Surv Ophthalmol. 2009;54:211–25.

    Article  PubMed  Google Scholar 

  7. George R, Paul PG, Baskaran M, Ramesh SV, Raju P, Arvind H, McCarty C, Vijaya L. Ocular biometry in occludable angles and angle closure glaucoma: a population based survey. Br J Ophthalmol. 2003;87:399–402.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  8. Marchini G, Pagliarusco A, Toscano A, Tosi R, Brunelli C, Bonomi L. Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma. Ophthalmol. 1998;105:2091–8.

    Article  CAS  Google Scholar 

  9. Markowitz SN, Morin JD. Angle-closure glaucoma: relation between lens thickness, anterior chamber depth and age. Can J Ophthalmol. 1984;19:300–2.

    CAS  PubMed  Google Scholar 

  10. Salmon JF, Swanevelder SA, Donald MA. The dimensions of eyes with chronic angle-closure glaucoma. J Glaucoma. 1994;3:237–43.

    Article  CAS  PubMed  Google Scholar 

  11. Dada T, Gadia R, Sharma A, Ichhpujani P, Bali SJ, Bhartiya S, Panda A. Ultrasound biomicroscopy in glaucoma. Surv Ophthalmol. 2011;56:433–50.

    Article  PubMed  Google Scholar 

  12. Moghimi S, Vahedian Z, Fakhraie G, Ghaffari R, Eslami Y, Jabarvand M, Zarei R, Mohammadi M, Lin S. Ocular biometry in the subtypes of angle closure: an anterior segment optical coherence tomography study. Am J Ophthalmol 2013; 155: 664-673, 73 e1.

  13. Lee JR, Sung KR, Han S. Comparison of anterior segment parameters between the acute primary angle closure eye and the fellow eye. Invest Ophthalmol Vis Sci. 2014;55:3646–50.

    Article  PubMed  Google Scholar 

  14. Lan YW, Hsieh JW, Hung PT. Ocular biometry in acute and chronic angle-closure glaucoma. Ophthalmologica. 2007;221:388–94.

    Article  PubMed  Google Scholar 

  15. Mimiwati Z, Fathilah J. Ocular biometry in the subtypes of primary angle closure glaucoma in university Malaya medical Centre. Med J Malaysia. 2001;56:341–9.

    CAS  PubMed  Google Scholar 

  16. Alsbirk PH. Primary angle-closure glaucoma. Oculometry, epidemiology, and genetics in a high risk population. Acta Ophthalmol Suppl. 1976;127:5–31.

    Google Scholar 

  17. Qi Y. Ultrasonic evaluation of the lens thickness to axial length factor in primary closure angle glaucoma. Yan ke xue bao = Eye science / "Yan ke xue bao" bian ji bu. 1993;9:12–4.

    CAS  Google Scholar 

  18. Mansoori T, Sarvepally VK, Balakrishna N. Plateau iris in primary angle closure glaucoma: an ultrasound biomicroscopy study. J Glaucoma. 2015;

  19. Mizoguchi T, Ozaki M, Wakiyama H, Ogino N. Plateau iris in Japanese patients with primary angle closure and primary angle closure glaucoma. Clin Ophthalmol. 2015;9:1159–63.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Collier Wakefield O, Annoh R, Nanavaty MA. Relationship between age, corneal astigmatism, and ocular dimensions with reference to astigmatism in eyes undergoing routine cataract surgery. Eye. 2016;30(4):562–9.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  21. Aung T, Ang LP, Chan SP, Chew PT. Acute primary angle-closure: long-term intraocular pressure outcome in Asian eyes. Am J Ophthalmol. 2001;131:7–12.

    Article  CAS  PubMed  Google Scholar 

  22. Mandell MA, Pavlin CJ, Weisbrod DJ, Simpson ER. Anterior chamber depth in plateau iris syndrome and pupillary block as measured by ultrasound biomicroscopy. Am J Ophthalmol. 2003;136:900–3.

    Article  PubMed  Google Scholar 

  23. Wand M, Pavlin CJ, Foster FS. Plateau iris syndrome: ultrasound biomicroscopic and histologic study. Ophthalmic Surg. 1993;24:129–31.

    CAS  PubMed  Google Scholar 

  24. Pavlin CJ, Ritch R, Foster FS. Ultrasound biomicroscopy in plateau iris syndrome. Am J Ophthalmol. 1992;113:390–5.

    Article  CAS  PubMed  Google Scholar 

  25. Chen YY, Chu D, Chou P. Enhancing the early differential diagnosis of plateau iris and pupillary block using a-scan ultrasonography. PLoS One. 2015;10:e0118811.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

None.

Funding

None.

Availability of data and materials

The data have not been placed in any online data storage. The datasets generated and analyzed during the study are available upon request from the first author.

Author information

Authors and Affiliations

Authors

Contributions

YS carried out the data collection, participated in the data analysis and drafted the manuscript. SJ carried out the data collection, participated in the data analysis and drafted the manuscript. AT participated in the data analysis and drafted the manuscript. LG participated in drafted the manuscript. WS conceived of the study, and participated in its design and coordination and helped to draft the manuscript. CT participated in its design, data collection and drafted the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Wasu Supakontanasan.

Ethics declarations

Ethics approval and consent to participate

This study followed the tenets of the Declaration of Helsinki and was approved by the ethics committee of the Ramathibodi Hospital, Mahidol University. Informed written consent was obtained from all participants.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Suwan, Y., Jiamsawad, S., Tantraworasin, A. et al. Qualitative and quantitative evaluation of acute angle-closure mechanisms. BMC Ophthalmol 17, 246 (2017). https://doi.org/10.1186/s12886-017-0635-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12886-017-0635-8

Keywords