IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2007;48:1592-1600.)
© 2007 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.06-1018

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bharadwaj, S. R.
Right arrow Articles by Schor, C. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bharadwaj, S. R.
Right arrow Articles by Schor, C. M.

Variation of Binocular-Vertical Fusion Amplitude with Convergence

Shrikant R. Bharadwaj,1,2 M. Pia Hoenig,1 Viswanathan C. Sivaramakrishnan,2 Baskaran Karthikeyan,2 Donna Simonian,1 Katie Mau,1 Sally Rastani,1 and Clifton M. Schor1

1From the School of Optometry, University of California at Berkeley, Berkeley, California; and the 2Elite School of Optometry, Medical Research Foundation, Chennai, Tamil Nadu, India.

PURPOSE. The maximum binocular vertical disparity that can be fused with disparity vergence (vertical-fusion amplitude or VFA), varies with convergence angle. VFA is larger for convergence responses to near than to far viewing distances; however, the clinical norms for changes in VFA with convergence have not been established. VFA at several convergence angles was measured to obtain a quantitative description of the changes in VFA with convergence.

METHODS. Fifty-six adults took part in the study. Horizontal and vertical disparity stimuli were presented on a computer monitor by using the red-green anaglyphic technique. Stimulus to convergence was altered either by changing horizontal disparity on the computer monitor (experiment I: nine horizontal disparities: 1.2–22.5 PD [{Delta}]) or by changing the binocular viewing distance (experiment II: five viewing distances: 25–300 cm). Convergence was held constant during an experimental session, while vertical disparity was incremented in steps of 0.05 {Delta} after a subjective report of fusion, until the subject reported diplopia. The maximum vertical disparity that could be fused was defined as the VFA.

RESULTS. VFA increased linearly over the range of convergence stimuli (y = 0.10x + 1.62) and intersubject variability of VFA increased marginally with the amount of convergence. Linear regression equations with similar slopes and y-intercepts were observed in experiments I and II.

CONCLUSIONS. The results of the experiments provide a quantitative description of a linear relationship between VFA and convergence. The linear regression equation could be used in a clinical setting to establish norms and to screen for vertical vergence abnormalities.