IOVS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


(Investigative Ophthalmology and Visual Science. 2006;47:3870-3877.)
© 2006 by The Association for Research in Vision and Ophthalmology, Inc.
DOI:  10.1167/iovs.05-0067

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (8)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reus, N. J.
Right arrow Articles by Lemij, H. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reus, N. J.
Right arrow Articles by Lemij, H. G.

Enhanced Imaging Algorithm for Scanning Laser Polarimetry with Variable Corneal Compensation

Nicolaas J. Reus,1 Qienyuan Zhou,2 and Hans G. Lemij1

1From the Glaucoma Service, The Rotterdam Eye Hospital, Rotterdam, The Netherlands; and 2Carl Zeiss Meditec, Inc., Dublin, California.

PURPOSE. To describe and investigate a method of improving assessment of retinal nerve fiber layer (RNFL) morphology with scanning laser polarimetry (SLP) with variable corneal compensation (VCC).

METHODS. By neutralizing anterior segment birefringence with a variable compensator, the current VCC method allows direct measurement of RNFL retardation. In the new method, enhanced corneal compensation (ECC), the variable compensator was set to introduce a "bias" birefringence. This bias was removed mathematically for each individual pixel to produce the RNFL image. In 177 eyes of healthy subjects, patients with glaucoma, and subjects with ocular hypertension, retardation images were obtained with both VCC and ECC.

RESULTS. In the tested eyes, images obtained with ECC showed the expected RNFL appearance better than those obtained with VCC. In addition, the typical scan score, which quantifies the amount of atypia, was higher with ECC than with VCC. The amount of residual anterior segment birefringence dropped significantly with ECC in the various groups. Measurements of peripapillary RNFL retardation showed reduced temporal and nasal values with ECC, whereas superior and inferior values were not significantly different between VCC and ECC. The dynamic range appeared to have increased with ECC. The accuracy of the TSNIT (temporal, superior, nasal, inferior, temporal) average and inferior average for detecting glaucoma was higher with ECC than with VCC.

CONCLUSIONS. RNFL morphology may be better assessed with the presented ECC method than with standard VCC. ECC may be implemented in the current VCC systems by means of a software upgrade. It may enhance the clinical utility of the GDx VCC in glaucoma management.





This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
J Choi, K H Kim, C H Lee, H Cho, K R Sung, J Y Choi, B-J Cho, and M S Kook
Relationship between retinal nerve fibre layer measurements and retinal sensitivity by scanning laser polarimetry with variable and enhanced corneal compensation
Br. J. Ophthalmol., July 1, 2008; 92(7): 906 - 911.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
F. A. Medeiros, C. Bowd, L. M. Zangwill, C. Patel, and R. N. Weinreb
Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation
Invest. Ophthalmol. Vis. Sci., July 1, 2007; 48(7): 3146 - 3153.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
M. Sehi, S. Ume, D. S. Greenfield, and Advanced Imaging in Glaucoma Study Group
Scanning Laser Polarimetry with Enhanced Corneal Compensation and Optical Coherence Tomography in Normal and Glaucomatous Eyes
Invest. Ophthalmol. Vis. Sci., May 1, 2007; 48(5): 2099 - 2104.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
T. A. Mai, N. J. Reus, and H. G. Lemij
Structure-Function Relationship Is Stronger with Enhanced Corneal Compensation than with Variable Corneal Compensation in Scanning Laser Polarimetry
Invest. Ophthalmol. Vis. Sci., April 1, 2007; 48(4): 1651 - 1658.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the Association for Research in Vision and Ophthalmology