Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print October 8, 2007, 10.1148/radiol.2452061054
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2452061054v1
245/3/888    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gietema, H. A.
Right arrow Articles by Prokop, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gietema, H. A.
Right arrow Articles by Prokop, M.
(Radiology 2007;245:888-894.)
© RSNA, 2007


Thoracic Imaging

Pulmonary Nodules: Interscan Variability of Semiautomated Volume Measurements with Multisection CT—Influence of Inspiration Level, Nodule Size, and Segmentation Performance1

Hester A. Gietema, MD, PhD, Cornelia M. Schaefer-Prokop, MD, PhD, Willem P. T. M. Mali, MD, PhD, Gerard Groenewegen, MD, PhD, and Mathias Prokop, MD, PhD

1 From the Departments of Radiology (H.A.G., W.P.T.M.M., M.P.) and Medical Oncology (G.G.), University Medical Center, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands; and Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (C.M.S.). From the 2005 RSNA Annual Meeting. Received June 18, 2006; revision requested August 23; revision received October 30; accepted November 22; final version accepted April 3, 2007. Address correspondence to H.A.G. (e-mail: h.gietema{at}umcutrecht.nl).

Purpose: To prospectively assess the precision of semiautomated volume measurements of pulmonary nodules at low-dose multi–detector row computed tomography (CT) and to investigate the influence of nodule size, segmentation algorithm, and inspiration level.

Materials and Methods: This study had institutional review board approval; written informed consent was obtained from all patients. Between June 2004 and March 2005, 20 patients (15 men, five women; age range, 40–84 years; mean age, 57 years) referred for chest CT for known lung metastases underwent two additional low-dose chest CT examinations without contrast material (collimation, 16 x 0.75 mm). Between these examinations, patients got off and on the table to simulate the conditions for a follow-up examination. Noncalcified solid pulmonary nodules between 15 and 500 mm3 that did not abut vessel or pleura were measured in both studies by using widely applied commercial semiautomated software. Interscan variability was established with the Bland and Altman approach. The impact of nodule shape (spherical or nonspherical) on measurement variability was assessed by using one-way analysis of variance, while the contributions of mean nodule volume and change in lung volume were investigated with univariate linear regression for completely (group A) and incompletely (group B) segmented nodules.

Results: Two hundred eighteen eligible nodules (volume range, 16.4–472.7 mm3; 106 spherical, 112 nonspherical) were evaluated. The 95% confidence interval for difference in measured volumes was –21.2%, 23.8% (mean difference, 1.3%). The precision of nodule segmentation was highly dependent on nodule shape (P < .001) and was weakly related to inspiration level for completely segmented nodules (r = –0.20; P < .047), while mean nodule volume did not show any effect (P = .15 and P = .81 for group A and B nodules, respectively).

Conclusion: Variation of semiautomated volume measurements of pulmonary nodules can be substantial. Segmentation represents the most important factor contributing to measurement variability, while change in inspiration level has only a weak effect for completely segmented nodules.

© RSNA, 2007