Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2431060554
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wang, C. L.
Right arrow Articles by Dunnick, N. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wang, C. L.
Right arrow Articles by Dunnick, N. R.
(Radiology 2007;243:80-87.)
© RSNA, 2007


Contrast Media

Frequency, Management, and Outcome of Extravasation of Nonionic Iodinated Contrast Medium in 69 657 Intravenous Injections1

Carolyn L. Wang, MD, Richard H. Cohan, MD, James H. Ellis, MD, Saroja Adusumilli, MD and N. Reed Dunnick, MD

1 From the Department of Radiology, University of Michigan Health System, Room B1D502G, 1500 E Medical Center Dr, Ann Arbor, MI 48109-0030. Received March 28, 2006; revision requested May 26; revision received June 5; accepted June 21; final version accepted August 25. Address correspondence to R.H.C. (e-mail: rcohan{at}umich.edu).

Purpose: To determine retrospectively the frequency, management, and outcomes of extravasations of intravenously injected nonionic iodinated contrast medium.

Materials and Methods: Institutional review board approval was obtained, and the requirement for informed consent was waived. The study was HIPAA compliant. For 69 657 intravenous injections of nonionic iodinated contrast medium for computed tomographic examinations between January 1, 2000, and March 31, 2005, the incident reports, radiology reports, and medical records of patients in whom contrast medium extravasations occurred were reviewed. Data collected included patient age, catheter gauge, injection site, volume extravasated, patient symptoms, severity of injury, treatment, whether or not the plastic surgery service was consulted and any additional treatment that service instituted, and patient outcome.

Results: Extravasations occurred in 475 (0.7%) of 69 657 patients, and follow-up information was available for 442 adults (280 women, 162 men; mean age, 57 years) and 17 children (nine girls, eight boys; mean age, 6 years). Extravasated volumes ranged from 3 to 150 mL. Symptoms usually consisted of swelling and/or pain. The plastic surgery service was consulted for 38 adults and six children and provided additional treatment in eight patients (seven adults, one child). Among adults, 432 had minimal or no adverse effects, nine had moderate adverse effects, and one had a severe complication (75 mL of contrast material extravasated into the hand, causing compartment syndrome). Only one moderate or severe complication in an adult resulted from an extravasation of less than 50 mL. Fifteen children had minimal or no adverse effects, one had moderate adverse effects, and one had a severe complication (18 mL of contrast material extravasated into the arm, causing brachial plexopathy).

Conclusion: Extravasation of nonionic iodinated contrast medium results only rarely in moderate or severe adverse effects, and these usually occur only when large volumes of contrast medium are involved.

© RSNA, 2007




This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
J. Singh and A. Daftary
Iodinated Contrast Media and Their Adverse Reactions
J. Nucl. Med. Technol., June 1, 2008; 36(2): 69 - 74.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2007 by the Radiological Society of North America.