Cardiac Imaging |
1 From the Institute of Diagnostic Radiology (H.A., S.W., B.B., S.L., L.M.D., B.M., T.B.), Clinic for Cardiovascular Surgery (A.P.), and Institute of Anesthesia (D.B.), Division of Cardiovascular Anesthesia, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich, Switzerland. Received March 17, 2005; revision requested May 10; revision received May 19; accepted June 20; final version accepted August 25. Supported by the National Center of Competence in Research, Computer Aided and Image Guided Medical Interventions of the Swiss National Science Foundation. Address correspondence to H.A. (e-mail: hatem.alkadhi{at}usz.ch).
Purpose: To prospectively evaluate whether planimetric measurements of aortic valve area (AVA) with 16detector row computed tomography (CT) allow classification of aortic stenosis (AS).
Materials and Methods: The study had institutional review board approval; patients gave informed consent. Twenty patients (11 men, nine women; mean age, 63 years) with AS and 20 patients (10 men, 10 women; mean age, 65 years) without underwent transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and retrospectively electrocardiographically gated 16detector row CT. Twenty CT data sets were reconstructed in 5% steps of R-R interval; data analysis was performed with four-dimensional software. Maximum AVA in systole planimetrically measured with CT (AVACT) was compared with AVA planimetrically measured with TEE (AVATEE), AVA calculated with the continuity equation and TTE (AVATTE), and transvalvular pressure gradients determined with the Bernoulli equation and TTE. Correlations among AVACT, AVATTE, AVATEE, and transvalvular pressure gradients were tested with bivariate regression analysis; agreement between methods was assessed with the Bland-Altman method.
Results: In patients without AS, mean AVACT was 3.56 cm2 ± 0.66 and mean AVATEE was 3.43 cm2 ± 0.69. In patients with AS, mean AVACT was 0.89 cm2 ± 0.35; mean AVATEE, 0.86 cm2 ± 0.35; and mean AVATTE, 0.83 cm2 ± 0.33. Mean transvalvular pressure gradient was 51 mm Hg ± 22. Significant correlations were present between AVACT and AVATEE (r = 0.99, P < .001), AVACT and AVATTE (r = 0.95, P < .001), and AVACT and transvalvular pressure gradients (r = 0.74, P < .01). Mean differences were 0.08 cm2 (limits of agreement: 0.32, 0.16) for AVACT versus AVATEE and 0.06 cm2 (limits of agreement: 0.15, 0.26) for AVACT versus AVATTE.
Conclusion: Planimetric measurements of AVA with retrospectively electrocardiographically gated 16detector row CT allow classification of AS that is similar to that achieved with measurements by using echocardiographic methods.
© RSNA, 2006
This article has been cited by other articles:
![]() |
J. P. Dal-Bianco, B. K. Khandheria, F. Mookadam, F. Gentile, and P. P. Sengupta Management of Asymptomatic Severe Aortic Stenosis J. Am. Coll. Cardiol., October 14, 2008; 52(16): 1279 - 1292. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. M. Feuchtner, W. Dichtl, S. Muller, D. Jodocy, T. Schachner, A. Klauser, and J. O. Bonatti 64-MDCT for Diagnosis of Aortic Regurgitation in Patients Referred to CT Coronary Angiography Am. J. Roentgenol., July 1, 2008; 191(1): W1 - W7. [Abstract] [Full Text] [PDF] |
||||
![]() |
W T Roberts, J J Bax, and L C Davies Cardiac CT and CT coronary angiography: technology and application Heart, June 1, 2008; 94(6): 781 - 792. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Ryan, S. Abbara, R. R. Colen, S. Arnous, M. Quinn, R. C. Cury, and J. D. Dodd Cardiac Valve Disease: Spectrum of Findings on Cardiac 64-MDCT Am. J. Roentgenol., May 1, 2008; 190(5): W294 - W303. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Grunenfelder, A. Plass, H. Alkadhi, and M. Genoni Evaluation of biological aortic valve prostheses by dual source computer tomography and anatomic measurements for potential transapical valve-in-valve procedure Interactive CardioVascular and Thoracic Surgery, April 1, 2008; 7(2): 195 - 200. [Abstract] [Full Text] [PDF] |
||||
![]() |
N E MANGHAT, V RACHAPALLI, R V. LINGEN, A M VEITCH, C A ROOBOTTOM, and G J MORGAN-HUGHES Imaging the heart valves using ECG-gated 64-detector row cardiac CT Br. J. Radiol., April 1, 2008; 81(964): 275 - 290. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Schroeder, S. Achenbach, F. Bengel, C. Burgstahler, F. Cademartiri, P. de Feyter, R. George, P. Kaufmann, A. F. Kopp, J. Knuuti, et al. Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology Eur. Heart J., February 2, 2008; 29(4): 531 - 556. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. F. Tops, S. C. Krishnan, J. D. Schuijf, M. J. Schalij, and J. J. Bax Noncoronary Applications of Cardiac Multidetector Row Computed Tomography J. Am. Coll. Cardiol. Img., January 1, 2008; 1(1): 94 - 106. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Alkadhi, L. Desbiolles, L. Husmann, A. Plass, S. Leschka, H. Scheffel, R. Vachenauer, T. Schepis, O. Gaemperli, T. G. Flohr, et al. Aortic Regurgitation: Assessment with 64-Section CT Radiology, October 1, 2007; 245(1): 111 - 121. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-P. Laissy, D. Messika-Zeitoun, J.-M. Serfaty, V. Sebban, E. Schouman-Claeys, B. Iung, and A. Vahanian Comprehensive evaluation of preoperative patients with aortic valve stenosis: usefulness of cardiac multidetector computed tomography Heart, September 1, 2007; 93(9): 1121 - 1125. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.-C. Pouleur, J.-B. le Polain de Waroux, A. Pasquet, J.-L. J. Vanoverschelde, and B. L. Gerber Aortic Valve Area Assessment: Multidetector CT Compared with Cine MR Imaging and Transthoracic and Transesophageal Echocardiography Radiology, September 1, 2007; 244(3): 745 - 754. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Stolzmann, H. Scheffel, D. Bettex, C. Karlo, T. Frauenfelder, R. Pretre, B. Marincek, and H. Alkadhi Subvalvular aortic stenosis: Comprehensive cardiac evaluation with dual-source computed tomography J. Thorac. Cardiovasc. Surg., July 1, 2007; 134(1): 240 - 241. [Full Text] [PDF] |
||||
![]() |
G. M. Feuchtner, S. Muller, J. Bonatti, T. Schachner, C. Velik-Salchner, O. Pachinger, and W. Dichtl Sixty-Four Slice CT Evaluation of Aortic Stenosis Using Planimetry of the Aortic Valve Area Am. J. Roentgenol., July 1, 2007; 189(1): 197 - 203. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |