BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

British Journal of Ophthalmology 2006;90:586-592; doi:10.1136/bjo.2005.082701
Copyright © 2006 by the BMJ Publishing Group Ltd.

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mitchell, L
Right arrow Articles by Sanderson, G
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mitchell, L
Right arrow Articles by Sanderson, G

EXTENDED REPORT

Star testing: a novel evaluation of intraocular lens optical quality

L Mitchell1, A C B Molteno2, T H Bevin2, G Sanderson2

1 Ophthalmology Department, Dunedin Hospital, Dunedin, New Zealand
2 Ophthalmology Section, Department of Medical and Surgical Sciences, University of Otago Dunedin School of Medicine, Dunedin, New Zealand

Correspondence to:
Correspondence to:
Dr Logan Mitchell
Ophthalmology Department, Dunedin Hospital, Private Bag 1921, Great King Street, Dunedin 9001, New Zealand; acb.molteno{at}stonebow.otago.ac.nz

Background: Despite the importance of optical quality of an intraocular lens (IOL) on visual outcomes following cataract surgery, objective data on their optical quality are not readily available, and manufacturing standards are industry regulated. The star test is a classic test of optical quality based on examination of the Airy disc and expanded diffraction rings of a point source of light, used mainly for telescope and microscope objectives.

Methods: A physical model eye cell allowed star testing of IOLs under conditions similar to the optical environment in which they operate. 18 IOLs were tested and results compared to actual images produced by these lenses in the model eye cell. Quantitative measures of star testing performance were developed.

Results: The optical performance of the IOLs varied, some performing very poorly. Most lenses (13/17) performed better in reverse orientation, while aberrations induced by the haptics of foldable IOLs were also detected. There was excellent correlation between actual images formed and star testing parameters.

Conclusion: Star testing IOLs was a novel biomedical application of a centuries old, inexpensive method. A concerning variation of optical quality was found, suggesting IOL optical performance data should be more readily available. Independent, authority mandated IOL optical quality standards should be developed, and results readily available to ophthalmologists.


Abbreviations: ANSI, American National Standards Institute; IOL, intraocular lens; ISO, International Standards Organisation; MTF, modulation transfer function; NA, numerical aperture

Keywords: intraocular lens; star test; optics







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2006 by the BMJ Publishing Group Ltd.