Abstract
In accelerators, the electron beam longitudinal dynamics critically depend on the energy distribution of the beam. Noninvasive, highly accurate measurement of the energy spread of the electron beam in the storage ring remains a challenge. Conventional techniques are limited to measuring a relatively large energy spread using the energy spread induced broadening effect of radiation source size or radiation spectrum. In this work, we report a versatile method to accurately measure the electron beam relative energy spread from to using the optical klystron radiation. A novel numerical method based on the Gauss-Hermite expansion has been developed to treat both spectral broadening and modulation on an equal footing. A large dynamic range of the measurement is realized by properly configuring the optical klystron. In addition, a model-based scheme has been developed for the first time to compensate the beam-emittance-induced inhomogeneous spectral broadening effect to improve the accuracy of the energy spread measurement. Using this technique, we have successfully measured the relative energy spread of the electron beam in the Duke storage ring from to with an overall uncertainty of less than 5%. The optical klystron is a powerful diagnostic for highly accurate energy spread measurement for storage rings and other advanced electron accelerators.
11 More- Received 28 May 2010
DOI:https://doi.org/10.1103/PhysRevSTAB.13.080702
This article is available under the terms of the Creative Commons Attribution 3.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI.
© 2010 The American Physical Society