Abstract
The lifetime of 2.21 ns previously attributed to the 5147 keV level in is assigned to the 4504 keV level and an upper limit of 1 ns is established for the lifetime of the 5147 keV level.
NUCLEAR REACTIONS (), MeV; coin; measured pulsed beam electronic timing; deduced . Enriched target, Ge(Li) detectors.
- Received 2 February 1977
DOI:https://doi.org/10.1103/PhysRevC.15.2245