The Discharge Mechanism of Self-Quenching Geiger-Mueller Counters

S. H. Liebson
Phys. Rev. 72, 602 – Published 1 October 1947
PDFExport Citation

Abstract

A split counter arrangement was used to investigate the absorption coefficient of the radiation which causes the discharge to spread along the wire of a counter after the triggering of a pulse. The counters used were filled with methylene bromide and argon at various pressures, and with ethyl alcohol and argon. The results indicate that the vapor dissipates electron energies, thereby reducing the number of photons produced during the discharge. It was also observed that the absorption coefficient is a function of the argon alone, from which it was concluded that photo-ionization of the argon is responsible for spreading the discharge along the wire. This behavior was also observed with helium and neon in combination with alcohol or methylene bromide.

  • Received 21 May 1947

DOI:https://doi.org/10.1103/PhysRev.72.602

©1947 American Physical Society

Authors & Affiliations

S. H. Liebson*

  • Naval Research Laboratory, Washington, D. C.
  • University of Maryland, College Park, Maryland

  • *Extracted from thesis submitted to the faculty of the Graduate School of The University of Maryland in partial fulfillment of the requirements for the degree of Doctor of Philosophy, based on work done at the U. S. Naval Research Laboratory.

References (Subscription Required)

Click to Expand
Issue

Vol. 72, Iss. 7 — October 1947

Reuse & Permissions
Access Options
Author publication services for translation and copyediting assistance advertisement

Authorization Required


×
×

Images

×

Sign up to receive regular email alerts from Physical Review Journals Archive

Log In

Cancel
×

Search


Article Lookup

Paste a citation or DOI

Enter a citation
×