Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on February 3, 2006
Radiation Protection Dosimetry 2005 117(1-3):222-224; doi:10.1093/rpd/nci752
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
117/1-3/222    most recent
nci752v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Kotre, C. J.
Right arrow Articles by Chapple, C.-L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kotre, C. J.
Right arrow Articles by Chapple, C.-L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

The influence of patient size on patient doses in cardiology

C. J. Kotre*, J. Reay and C.-L. Chapple

Regional Medical Physics Department, Newcastle General Hospital, Newcastle-upon-Tyne NE4 6BE, UK

* Corresponding author: John.Kotre{at}nuth.northy.nhs.uk

In cardiology and interventional radiology, areas that contribute large components to medical radiation exposure, a major source of variation in patient dose is the variation in complexity between cases for nominally identical procedures. In patient dose surveys, this variation tends to mask that due to patient size. The effect of applying a previously defined size correction to cardiology patient dose–area product (DAP) records was investigated. The correction method uses the experimentally determined relationship between patient diameter and DAP to derive a factor to convert DAP to that which would be expected had the patient been similar in size to ICRP Reference Man. The size correction was found to greatly reduce the residual correlation of DAP with patient weight. An implication of this finding is that data collection for the setting of diagnostic reference levels in cardiology can be performed for all patients rather than just ‘standard-sized’ patients.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.