Paper The following article is Open access

Development of HFCT for partial discharge sensors

, , , , , , , , , , , , and

Published under licence by IOP Publishing Ltd
, , Citation E P Waldi et al 2019 IOP Conf. Ser.: Mater. Sci. Eng. 602 012015 DOI 10.1088/1757-899X/602/1/012015

1757-899X/602/1/012015

Abstract

This paper presents partial discharge (PD) measurement techniques using a commercial sensor, High-Frequency Current Transformer (HFCT). An Output signal from HFCT is read by a digital oscilloscope and compared with the reading of convensional that PD detector. When PD occurs, the signals detected using high impedance that has a long time of oscillations and cause the delay of next reading of PD signals. To avoid this issue, the time of oscillations must be reduced by installing a damper which is a resistor connected in parallel between the sensor and the oscilloscope. The result of the measurement shows that the damper has the same reading on peak values as read by the convensional PD detector.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1757-899X/602/1/012015