Brought to you by:
Paper The following article is Open access

Commutator fault detection of brushed DC motor using thermal assessment

, and

Published under licence by IOP Publishing Ltd
, , Citation Abbas A Wahab et al 2019 IOP Conf. Ser.: Mater. Sci. Eng. 469 012057 DOI 10.1088/1757-899X/469/1/012057

1757-899X/469/1/012057

Abstract

In this paper fault detection of brushed DC motor is described. Recently, Thermal Signature Analysis (TSA) has become a common tool for fault analysis of AC induction motors. Currently, very little research has been performed using thermal signature analysis on brushed DC motors. This paper is a present fault detection of DC motors using thermal signature analysis. In order to organize the detection, the thermal behaviour of DC motor was analysed using the K-type thermocouple with data logger. The thermocouples were mounted on 4 part of the DC motor, casing, permanent magnet, brush and bearing. The initial measurements of thermal behaviour were realized by using healthy DC motor as a sample of a thermal behaviour. Furthermore, the measurements of thermal behaviour for the same type of motor with thick carbon impurities on commutator has been implemented to compare with the thermal behaviour of healthy DC motor. The significant observation on steady state temperature of thermal behaviour between healthy DC motors and faulty DC motor will be analysed. From the analysis of thermal behaviour between healthy DC motor and commutator fault DC motor, that can clearly recognize the commutator fault by through the different of characteristic temperature profile of DC motor.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1757-899X/469/1/012057