Paper The following article is Open access

Air Permeability of Renovation Plasters Evaluated with Torrent's Method

and

Published under licence by IOP Publishing Ltd
, , Citation Krystian Brasse and Tomasz Tracz 2017 IOP Conf. Ser.: Mater. Sci. Eng. 245 032071 DOI 10.1088/1757-899X/245/3/032071

1757-899X/245/3/032071

Abstract

The aim of research was to determine the air permeability of the renovation plasters, using Torrent's method. The scope of this research included three renovation plaster systems. Each of them was applied on experimental, masonry element and had a different rendering coat. Permeability measurements were performed after 28 days of curing in a natural state. In order to calculate the coefficient of air permeability (kT), the partial data was registered during the measurements. The test results indicate the possibility of determination the coefficient of air permeability kT in relation to the renovation plasters. At the same time results confirm the high porosity of the renovation plasters.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.