Paper The following article is Open access

Experimental investigation on mixed refrigerant cryocooler operating at 70 K for cooling high temperature superconductors

and

Published under licence by IOP Publishing Ltd
, , Citation Narayanan Vineed and G Venkatarathnam 2017 IOP Conf. Ser.: Mater. Sci. Eng. 171 012073 DOI 10.1088/1757-899X/171/1/012073

1757-899X/171/1/012073

Abstract

The paper deals with a Mixed Refrigerant Cascade refrigerator operating at 70 K. A mixture of nitrogen, neon and hydrocarbons has been used as the refrigerant. A lowest temperature of 64 K was achieved on no load, 70 K at 2 watts and 75 K at 5 watts. The details of the study are presented in this paper.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.